You have just purchased a quality Coalescent Filter from Master Pneumatic. 

 

With care in its installation and maintenance, you can expect it to have a long and economical service life.   

Before you go any further, please take a few minutes to look over this information,  

then save it for future reference and for the useful service information it contains.   

NOTE: 

Read Warning Stuffer STU-A019 included in box with product before proceeding.

 

 
INSTALLATION: 

1. Depressurize and lockout air pressure. 
2. Upstream pipes must be free of excessive dirt and liquids.  
3. A conventional M/P Filter with standard 5 micron filter element should be installed immediately ahead of Coalescing Filters 

to maximize the life of the coalescing element. 

4. Install the Coalescent Filter as near as possible to the device it is to serve. 
5. Install the Coalescent Filter so that air flows from inlet to outlet as shown on the head.  
6. The Coalescent Filter must be installed vertically with drain mechanism at the bottom. 
7. Coalescent Filters should be installed upstream of any Regulators or Lubricators in the airline. 
 

OPERATION: 

1. For Manual Drain models: Periodically drain to discharge accumulated liquids by turning Draincock clockwise.  
2. For Automatic Drain models: Flexible tubing (3/16” ID) may be installed on the Drain Stem to remove discharges. Turn 

Drain Knob counter-clockwise until it stops, push up to expose the Drain Clip. Remove Drain Clip and Drain Knob, and push 
tubing onto Drain Stem. The drain may be adjusted to compensate for differing operating conditions by adjusting the Drain 
Knob. For low flow or low pressure drop, turn the Drain Knob until the drain just closes. For high flows or high pressure 
drop, turn the Drain Knob clockwise if reduced drain action is required. Turning the Drain Knob clockwise to the stop puts 
the drain in a manual shutoff position. Turning the Drain Knob counter-clockwise will manually drain the filter. 

3. Replace Coalescent Element when the pressure differential reaches 8 to 10 psid (0.55 to 0.69 bar). 
 

TO CLEAN OR REPAIR: 

1. Depressurize and lockout air pressure. 
2. Remove Bowl Ring and Bowl Assembly by turning counter-clockwise. 
3. Remove Lower Baffle by turning counter-clockwise.  
4. The Coalescent Element can now be removed. Do NOT clean elements, they must be replaced.  
5. To service Automatic Drain, turn Drain Knob counter-clockwise until it stops. Then push Drain Knob up to expose Drain Clip. 

Remove Drain Clip and pull off Drain Knob. 

6. Remove Drain Nut by turning counter-clockwise. The Automatic Drain can now be removed from Bowl and disassembled.  
7. The Automatic Drain and Bowl can now be cleaned with soap and water.   
8. When re-assembling, be sure all o-rings are correctly located. Lubricate o-rings with Lithium grease. Torque Drain Nut 5-15 

in-lbs. Torque Lower Baffle 50-75 in-lbs. Torque Bowl Ring hand tight. 

9. If the Coalescent Filter cannot be repaired by cleaning with soap and water, the parts should be replaced. 

BFCD201

 Installation and Maintenance 

MASTER PNEUMATIC  -  DETROIT, INC.   

6701 -18 Mile Rd

. | 

Sterling Heights, MI 48314   |   Phone: (586) 254-1000  |  Fax: (586) 254-6055  |  Email: [email protected] 

STU-5015 

JAA 6-29-06 

REV 08-29-08 

(ECN 4460) 

Replacement Parts 

 DESCRIPTION 

PART NUMBER 

Element Kit - 0.3µm  

A114-112 

Ext. Bowl Element Kit - 0.3µm 

A114-113 

Element Kit - 0.01µm 

A114-112E8 

Ext. Bowl Element Kit - 0.01µm 

A114-113E8 

 

 

Automatic Drain Kit 

D380 

Manual Draincock 

103-51SP  

DESCRIPTION 

PART NUMBER 

AID Metal Bowl Assembly 

ABFD114-100 

AID Metal Ext. Bowl Assembly 

ABFD114-100H 

Manual Metal Bowl Assembly 

ABF114-100 

Manual Metal Ext. Bowl Assembly 

ABF114-100H 

 

 

Differential Pressure Gauge 

106-35 

PRODUCT NUMBERS: 

 

BFCD201-10 
BFCD201-12 

Installation & Operation Procedures 