![Master Bilt MBGFP-HG Installation & Operation Manual Download Page 8](http://html1.mh-extra.com/html/master-bilt/mbgfp-hg/mbgfp-hg_installation-and-operation-manual_1736993008.webp)
2/20 Rev. A 57-02694
8
MECHANICAL
CAUTION
Risk of fire or explosion due to puncture of refrigerant tubing; follow handling
instructions carefully. Flammable refrigerant used.
CAUTION
Installation and service of the refrigeration and electrical components of the cabinet
must be performed by a refrigeration mechanic and/or a licensed electrician.
Remove front grille and check refrigeration lines to see that they are free (not touching each other or compressor).
Refrigeration system processing tubes for a cabinet possessing flammable refrigerant is painted red. Spin condenser
fan blade to see that it is free. Insulate quick connects with pipe insulation to prevent condensation and/or ice
accumulating.
Remove cabinet from crate base and slide into location. Cabinet must be level from side to side and front to back for
correct draining of coil pan and for self-closing doors to operate correctly. Allow minimum of 4” between back of
cabinet and wall and between top of cabinet and ceiling for proper condensing unit air circulation.
To comply with Sanitation requirements the cabinet must be mounted on legs (6” high min.), casters, or the base
must be sealed to the floor with an N.S.F. listed silicone sealant. When sealing to the floor, leveling bolts can be uses
to assure the cabinet is level before applying silicone sealant.