MASTER-BILT

®

 PART LIST 

 

The table below gives Master-Bilt

®

 part numbers.  Use this chart when ordering replacement parts for your 

IHC 

cabinets. Always Advise Cabinet Serial Number When Ordering Parts 
 

Description

 

IHC-27 

IHC-48 

Coil Defrost Heater 

17-00442 

17-09076 

Compressor 

 

03-14403 

03-14985 

Condensate Heater 

17-09412 

17-09084 

Condenser Coil 

07-13076 

07-14172 

Condenser Fan Motor Assembly 

13-13436 

13-13436 

Electronic Controller  

19-14605 

19-14605 

Box sensor T1 

19-14244 

19-14244 

Evaporator sensor T2 

19-14245 

19-14245 

Contactor 

19-13934 

19-13934 

Door Handle 

35-01488 

35-01488 

CRO Valve 

09-00992   12.5p set 

09-00987 22 # Setting 

Door Gasket 

37-01207 

37-01211 

Door Hinge-Inner Doors-L.H. 

 

35-01451 

Door Hinge-Inner Doors-R.H. 

35-01452 

35-01452 

Door Hinge-Outer Doors 

35-01450 

35-01450 

Door Trim 

29-01481 

29-01380 

Drain Line Heater 

17-09063 

17-09063 

Drain Pan Heater 

 

17-09075 

Drier 

09-09171 

09-09846 

Evaporator Coil 

07-00750 

07-13084 

Evaporator Motor Assembly 

15-13159 

13-13439 

Expansion Valve 

09-09543 

09-09543 

Female Plug 

21-00577 

 

Front Control 

19-00899 

19-00899 

Heater Safety Control 

19-01307 

19-01307 

Leg 

27-00558 

27-00558 

Compressor Switch 

19-13118 

19-13168 

Shelves (Cantilever) 

33-01519 

33-01518 

Sight Glass 

 

09-09505 

Remote Display for Ele. Controller 

19-14607 

19-14607 

Meter Long Cable for Ele. Controller 

19-14608 

19-14608 

 
SALE AND DISSPOSAL 

 

OWNER RESPONSIBILITY 

 
If you sell or give away your Master-bilt cabinet you must make sure that all safety labels and installation – service 
manual are included with it.  If you need repacement labels or manual, Master-bilt will provide them free.  Contact 
the customer service department at Master-bilt at (800) 684-8988. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for IHC-27

Page 1: ...6 17Rev E 57 02410 Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 ...

Page 2: ...6 17 Rev E 57 02410 2 ...

Page 3: ... Electrical 7 Leg and Condensate Pan Installation 8 SERVICE INSTRUCTIONS 4444444444444444444444444444444 4444 4 8 TEMPERATURE SENSOR DEFROST HEATER AND FAN MOTOR REPLACEMENT444444 4444 4 9 ELECTRONIC REFRIGERATION CONTROL4444444 44444444444444444 44 410 11 SENSOR TEMPERATURE AND RESISTANCE4444444 44444444444444444444 4 12 FINAL CHECK LIST44444444444444444444 444444444444 44 44444412 ACCESSORIES444...

Page 4: ... for the circulation of air behind the case which will prevent condensation on the exterior surfaces NOTICE Read this manual before installing your cabinet Keep the manual and refer to it before doing any service on the equipment Failure to do so could result in personal injury or damage to the cabinet DANGER Improper or faulty hook up of electrical components on the refrigeration units can result...

Page 5: ... signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUTION Minor injury or damage to your cabinet can occur if you ignore the message NOTICE This is important installation operation or service information If you ignore the message you may damage your cabinet...

Page 6: ...ck so that older stock does not accumulate This is especially important for ice cream A First In First Out rotation practice will keep the products in good salable condition 4 Do not place product in the case when it is soft or partially thawed Also product should not be put in the case for at least 6 hours after it is started 5 Stock cases as quickly as possible exposing only small quantities to ...

Page 7: ... and wall and between top of cabinet and ceiling for proper condensing unit air circulation To comply with Sanitation requirements the cabinet must be mounted on legs 6 high min or casters or the base must be sealed to the floor with an N S F listed silicone sealant To comply with UL requirements the cabinet must have a minimum clearance of 4 at the top 6 at the rear and 0 at each side ELECTRICAL ...

Page 8: ...y pan level behind or slide under the IHC cabinet 2 Route the drain line of the cabinet to the pan so the water can drip into the pan during defrost Do not let the drain tube touch the drain pan s heater It can melt the tube or even catch it on fire 3 Plug the drain pan into a separate 115V power supply SERVICE INSTRUCTIONS 1 High head pressure and high back pressure A Condenser coil clogged or re...

Page 9: ... plastic tie to tighten the zone sensor Insert the sensor for defrost termination firmly into the evaporator coil in between the fins Make sure the sensor wires do not touch or are not close to any heater rods To change defrost heater remove screws from drain pan and pull down remove screws from coil mounting straps spring straps open remove heater shield pull heater out of slots in coil fins To c...

Page 10: ...s 2 minutes delay after a defrost before the fan comes on If the Evaporator temperature is 35 o F or below the controller will override the fan delay FAN indicator is on while FAN relay is energized Defrost The control uses time defrost with 2 defrost per day The defrost scheme can be re set the for special applications During defrost the display will show dEF when the defrost indicator on The con...

Page 11: ... Defrost Cycle per 24hr 0 99 hours 12 DLI Defrost Termination Temperature 50 120 55 F DTO Maximum Defrost Duration 1 120min 35min ELECTRICAL CONNECTIONS The controller is provided with screw terminal block to connect cables with a cross section up to 2 5 mm 2 Before connecting cables make sure the power supply complies with the control s requirements Separate the probe cables from the power supply...

Page 12: ...supply voltage C Set temperature control for desired temperature setting D Check sight glass if applicable for proper refrigerant charge E Check to make sure the compressor switch behind the front grill is on before start up the cabinet F Check condensing unit for vibrating or rubbing tubing Dampen and clamp as required G All valves should be completely opened counter clockwise H Check packing nut...

Page 13: ...R H 35 01452 35 01452 Door Hinge Outer Doors 35 01450 35 01450 Door Trim 29 01481 29 01380 Drain Line Heater 17 09063 17 09063 Drain Pan Heater 17 09075 Drier 09 09171 09 09846 Evaporator Coil 07 00750 07 13084 Evaporator Motor Assembly 15 13159 13 13439 Expansion Valve 09 09543 09 09543 Female Plug 21 00577 Front Control 19 00899 19 00899 Heater Safety Control 19 01307 19 01307 Leg 27 00558 27 00...

Page 14: ...6 17 Rev E 57 02410 14 DESCRIPTION DATE MODEL S IHC 27 48 3 6 15 LAE BIT25 CONTROLLER REVISION A 6 23 16 REVISION B 6 13 17 ...

Page 15: ...6 17 Rev E 57 02410 15 DESCRIPTION DATE MODEL S IHC 27 48 3 6 15 LAE BIT25 CONTR REMOTE REVISION A 6 23 16 REVISION B 6 13 17 ...

Page 16: ...6 17 Rev E 57 02410 16 DESCRIPTION DATE MODEL S IHC 27 48 3 6 15 LAE BIT25 BOOSTING TRANS REVISION A 6 23 16 REVISION B 6 13 17 ...

Reviews: