••••  www.master-bilt.com  •  Pg. 9 •••• 

 

MAINTENANCE GUIDELINES 

 

Regularly and carefully cleaning the equipment prevents deterioration and product alteration. 

 

CLEANING THE UNIT 

 

Clean every week with only a damp piece of cloth and neutral soap each 
external and internal surface, and dry them with a clean soft cloth 

 

Never use flammable or abrasive products. The unit must never 

be cleaned 

with water jets. 

 

IMPORTANT: 

During  maintenance  and  cleaning  operations,  make  sure 

that  good  visibility  conditions  exist  in  the  working  area,  using  other  light 
sources  in  case  it  is  needed.  Be  very  careful  when  working  with  moving 
and/or high-temperature parts. 

 

CLEANING THE CONDENSER COIL 

 

IMPORTANT WARRANTY INFORMATION: 

Condensers accumulate dirt and require regular cleaning. Dirty condensers result in 

compressor failure, product loss, and lost sales; which are not covered by warranty 

 

If you keep the condenser(s) clean you will minimize your service expense and lower your electrical 
costs.  The following is a step-by-step guideline for the cleaning of the condenser(s): 

 

1.

 

Disconnect power to the unit. 

2.

 

Take off front lower grill assembly by removing the two (2) screws in the top corners. 

3.

 

Clean off accumulated dirt from the condenser coil(s) using a vacuum and/or a damp rag. 

4.

 

Replace the grill assembly. 

5.

 

Connect power to the unit and verify that when required the condensing unit(s) are running. 

 

If you cannot remove the dirt adequately, please call your refrigeration service company. 

 

Summary of Contents for BGR15

Page 1: ...North New Albany MS 38652 800 647 1284 Fax 866 882 7629 INSTALLATION AND OPERATION MANUAL BGR15 Congratulations You have just purchased the finest commercial refrigeration available 6 16 Rev A 57 025...

Page 2: ...Master Bilt cooler when installed correctly and properly maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL W...

Page 3: ...pt in storage it is suggested to keep it in its original packing In case you need your equipment to be inactive for a long period of time after being used verify that it has been unplugged After clean...

Page 4: ...of the refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from s...

Page 5: ...heck that the electrical data on the data plate match your electrical output IMPORTANT NOTICE PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAM...

Page 6: ...eration of the unit based on the temperature of the air discharging from the evaporator at the back of the unit In order to achieve the desired product temperature the electronic control is factory ad...

Page 7: ...ATION EVAPORATOR TRAY When the equipment operates condensed water from the environment is collected on the evaporator During each off cycle the water drains to the evaporator tray located at the botto...

Page 8: ...unit Do not allow the electronic control to be adjusted by customers or unqualified personnel For any adjustment you must contact your distributor Verify that the hot air stream from the condenser tow...

Page 9: ...rts CLEANING THE CONDENSER COIL IMPORTANT WARRANTY INFORMATION Condensers accumulate dirt and require regular cleaning Dirty condensers result in compressor failure product loss and lost sales which a...

Page 10: ...t immediately contact your distributor specifying the kind of problem and clearly indicating the equipment model and serial number If replacing parts is required do it through your distributor WARNING...

Reviews: