background image

Master Audio

Xcellence Series XLT.Ver 1.0

Feb 10

15

Once  a  memory  or  preset  is  loaded,  it  will  remain  in  the  memory  even  is  the 
equipment is powered off. Next time the unit is powered on, the last loaded memory 
will be used. After some seconds of inactivity of the keypad, the keypad and LCD will 
automatically lock.

b)  With  external  PC

.  Once  the  required  connections  between  the  cabinets  and  PC 

are  made,  the  cabinets  can  be  controlled  by  the  PC.  All  functions  described  above 
plus 5 parametric EQ or filters (Butt-LR-Shelf) can be configured.
For more information about the software and the connections required, please refer to 
the  DSPController Manual  or Quick  Installation Guide,  available  at your dealer  or at 
Master Audio’s technical service: 

[email protected]

8. MOUNTING AND INSTALLATION

Whenever possible, mount the Full Range units in a high position (between 2 and 3 
meters above ground), angled towards the audience. If the units are mounted close to 
the ground the back row listeners will receive low quality sound.

Fig.9. Orientation of Xcellence full range units(X-15LT)

The X-15LT model incorporates a 35mm pole mount socket for standard tripod in the 
lower side. To use the socket, unscrew the four bolts on the central face plate.

Fig.10. Top side (left) and socket for tripod (right)

Summary of Contents for X-15LT

Page 1: ...XCELLENCE SERIES X 15LT X 18W Systems Pol Ind Norte Perpiny 25 08226 TERRASSA Barcelona SPAIN Copyright 2010 info master audio com All rights reserved master audio com Feb 10 User s manual...

Page 2: ...pment where its ventilation system might be interfered with 7 Do not install the device near heat sources such as radiators heaters or other heat emitting elements 8 The equipment must be repaired by...

Page 3: ...2 Features and appearance X 15LT Self powered cabinet 1000W amplifier for mid range 500W amplifier for high range DSP with 48 bit bus and 28 bit filter coefficients DSP Controls parametrics delay volu...

Page 4: ...rcuit protection at the output maximum power limiters for each channel and protection against overvoltage The DSP includes 5 presets which can be selected either accessing the cabinet s rear control p...

Page 5: ...er Audio Xcellence Series XLT Ver 1 0 Feb 10 5 P1 FACTORY Flat response freefield P2 NEARFIELD 3dB Mid nearfield P3 LOUDNESS 6dB Mid nearfield deeper mid range correction P4 SPEECH 9dB Low 6dB High sp...

Page 6: ...ction of various cabinets with the same input signal 1 Shield 2 Live 3 Return e AC INPUT Mains supply via PowerCon f AC LINK Power link for PowerCon connector to feed other units in parallel up to a m...

Page 7: ...ence Series XLT Ver 1 0 Feb 10 7 C A D B E G F Fig 2 X 15LT connection panel Always use mains power cable supplied by manufacturer Never connect the XLT to an unearthed mains supply or by using an une...

Page 8: ...resets LPF90 LP110 LPF130 LPF90 LPF110 LPF130 make it easy flexible and user friendly The 18 neodymium woofer used thanks to its exclusive magnetic design combines excellent bass frequency response hi...

Page 9: ...r via the computer with RJ45 connection for the RS485 bus The LPF90 and LPF90 presets mean low pass filter at 90Hz LPF110 and LPF110 mean low pass filter at 110Hz LPF130 and LPF130 mean low pass filte...

Page 10: ...18W is used in conjunction with the X 15LT in XOVER preset the X 18W must operate in positive polarity LPF90 LP110 LPF130 When the X 18W is used in conjunction with the X 15LT in FACTORY NEARFIELD LO...

Page 11: ...l 1 Shield 2 Live 3 Return e AC INPUT Mains supply via PowerCon f AC LINK Power link for PowerCon connector to feed other units in parallel up to a maximum of 3 extra units g AC INDICATORS Power suppl...

Page 12: ...units in this chain must be switched on For the mains connection in parallel use the cable with grey Neutrik PowerCon NAC3FCB at one end and the blue Neutrik PowerCon NAC3FCA at the other end Do not c...

Page 13: ...lectrical fault 7 FUNCTIONS of the INTERNAL DSP All the XCELLENCE series are equipped with an internal DSP unit which can be operated by the LCD and keypad located at the rear panel of the cabinet and...

Page 14: ...t that it is necessary to store the modified settings using the SAVE function The new settings will be stored in a memory slot which will be identified bny an 8 character name given by the user Select...

Page 15: ...information about the software and the connections required please refer to the DSPController Manual or Quick Installation Guide available at your dealer or at Master Audio s technical service sat am...

Page 16: ...rporates a base plate on its upper side for the attachment of a standard 35mm diameter bar Fig 11 Combination with subwoofer 9 FLYING X15LT provides M10 flying points Their correct use will permit the...

Page 17: ...Master Audio Xcellence Series XLT Ver 1 0 Feb 10 17 Fig 12 Flying points...

Page 18: ...tput level PR FACTORY 131 dB SPL Total amplifier power 1500 W Power delivered to transducers LF 1000 W HF 125 W Nominal directivity 6dB 60 x 50 Components LF 1 x 15 neodymium woofer 4 voice coil HF 1...

Page 19: ...level 128 dB SPL preset LPF130 Total amplifier power 1500 W Nominal directivity 6dB Horizontal omnidirectional Vertical omnidirectional Components LF 1x18 neodymium woofer 4 voice coil Cabinet Height...

Page 20: ...he system is being saturated with a very high input signal frequently caused by the same mixer Check the output level or mixer gain channels Poor bass levels Check the polarity on the signal connectio...

Reviews: