background image

Amate Electroacústica,s.l. 

MAW218D.Version 1.2 

 

Nov 08 

5

A) 

RJ45 INPUT

 : PC Signal Input 

 
B) 

RJ45 LINK

 : PC Link Signal 

 
C) 

INPUT SIGNAL

 : Balanced XLR input signal connector  

 1= Ground   2= Live      3= Return 

 
D) 

LINK INPUT SIGNAL

 : Balanced XLR connector for paralleling several units, which 

will share the same input.  

1= Ground   2= Live       3= Return 

 
E) 

AC INPUT

 :  Input PowerCon connector. 

 
F) 

AC STACKING OUTPUT

 : PowerCon Output connector to feed a secondary 

cabinet.  

 

G)

 LED OVERVOLTAGE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig.2.

 Connections panel for 

MAW-218/D 

 
 
3- OVERVOLTAGE PROTECTION 
 

The MAW218D includes overvoltage protection. 
  
An electronic circuit compares the input voltage with a reference value on the AC 
Input connector (MAINS). When the input voltage is higher than 250 Volts the circuit 
starts to work, blocking the input voltage until its value returns to its correct limits 
(230V +/- 10% ). 
  

Summary of Contents for MAW218D7

Page 1: ...MAW218D7 User s manual Pol Ind Norte Perpiny 25 08226 TERRASSA Barcelona SPAIN info master audio com www master audio com Nov 2008...

Page 2: ...l water fountain or any liquid sources 5 Clean only with a dry cloth 6 This product should be situated so that its location does not interfere with its proper ventilation 7 Do not install near heat so...

Page 3: ...trolled by the volume of its two chambers We obtain an excellent performance with very low levels of distortion 2 1 18 Neodymium Loudspeakers The 18 transducers used which are probably the best ones o...

Page 4: ...amplification modules are 3000 W Their high efficiency almost 90 allows their location on the rear panel without the necessity of forced cooling We eliminate any fan or any other auxiliary device whi...

Page 5: ...e 3 Return E AC INPUT Input PowerCon connector F AC STACKING OUTPUT PowerCon Output connector to feed a secondary cabinet G LED OVERVOLTAGE Fig 2 Connections panel for MAW 218 D 3 OVERVOLTAGE PROTECTI...

Page 6: ...cabinet stops working or works intermittently until the correct voltage values are reached again 4 FLYING The MAW218D cannot be flown 5 STACKING The STK210 218 Hardware adapts the MAW218 with the MA2...

Page 7: ...Vertical omnidirectional System Output Continuous SPL Long Term One enclosure 3000 W 138 dB Two enclosures 3000 W 144 dB Four enclosures 3000 W 150 dB Components LF 2x18 Long excursion Neodymium Woofe...

Page 8: ...he processor do not have a Mute on Distorted sound The system is overloaded and has reached maximum power Turn down the mixer s output or the channel s gain Poor bass performance Check the polarity of...