background image

DSP Series

DSP306USB
DSP408USB

Firmware v9.xx

Software DSPLink v9.xx

Pol. Ind. Norte - Perpinyà, 25

                                                                  08226 TERRASSA (Barcelona-SPAIN)

Copyright © 2010

                         

[email protected]

All rights reserved

                                            www.master-audio.com

             

     

       

Nov 10

User Manual

Summary of Contents for DSP306USB

Page 1: ...DSP306USB DSP408USB Firmware v9 xx Software DSPLink v9 xx Pol Ind Norte Perpiny 25 08226 TERRASSA Barcelona SPAIN Copyright 2010 info master audio com All rights reserved www master audio com Nov 10 U...

Page 2: ...able operation of the limit and to protect it from overheating These openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or similar su...

Page 3: ...tlet and disconnect the antenna or cable system This will prevent damage to the unit due to lightning and power line surges 13 REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL SERVICING IS REQUIRED...

Page 4: ...EQ per channel 31 bands of graphic EQ per input multiple crossover selections and full function limiters Precise frequency control is achieved with its 1 Hz resolution Inputs and outputs can be routed...

Page 5: ...ncy Resolution 8 Parametric Equalizers for each Input and Output 31 band Graphic Equalizer for each Input Multiple Crossover types with Full Function Limiters Precise Level Polarity and Delay CPU and...

Page 6: ...uts and outputs are linked separately C Channel Menu LED Indicates the activated channels for parameter modification D Peak Level LED Indicates the current peak level of the Signal Signal 12dB 6dB 3dB...

Page 7: ...System Menu In delay and frequency adjustments 1 Hz resolution mode modifies data values by 100X used with thumb wheel Exit Exit to the Main Menu G Rotary Thumb Wheel Changes parameter data values The...

Page 8: ...t The voltage input is 90 240VAC 50 60Hz D Ethernet slot Slot to install the optional Ethernet module With this accessory the unit can be connected to a router switch or PC through CAT 5 cable E XLR i...

Page 9: ...irmware version After that the DSP unit displays its main screen The screen shows the current program number and program name assigned to the unit The program assigned is always the last program the u...

Page 10: ...ing menus are available for each input channel 6 1 1 Signal Signal parameters LEVEL Gain 40 00dB to 15 00dB in 0 25dB steps POL Polarity can be normal or inverted DELAY Delay in 11us steps It can be d...

Page 11: ...SHF and AP 2 For AP 1 the bandwidth sets the phase shift at the centre frequency This phase is gradually changed from 180 degrees above the centre frequency to the specified value LEVEL EQ level gain...

Page 12: ...can be selected in the System Menu SLPL Filter Slope of low frequency crossover point high pass Ranges from 6 to 48dB octave If the selected Filter Type is Linkwitz Riley the available slopes are 12...

Page 13: ...teps ATTACK Attack time Ranges from 0 3 to 1ms in 0 1ms steps then ranges from 1 to 100ms in 1ms steps RELEASE Release time Can be set at 2X 4X 8X 16X or 32X the attack time Filter config Low Xover po...

Page 14: ...hannel may be selected by holding the Menu key and pressing the corresponding Mute key Press Exit to deselect all The following menus are available for each ouput channel 6 2 1 Signal Signal parameter...

Page 15: ...nput 4 only available for DSP408 6 2 6 Ch Name Channel Name Refer to the Input Menus for details 6 3 System Menu The System Menu allows the user to control and change parameters that are related to th...

Page 16: ...r for the current data to be stored NAM Program Name allows a maximum length of 12 characters 6 3 3 Config Device Configuration MODE configures the mode of operation The possible modes are shown in th...

Page 17: ...eters will be copied When one of the Source or the Target is an input while the other is an output only the Level Polarity Delay and EQ are copied SOURCE Channel to be copied from TARGET Channel to be...

Page 18: ...password first in order to modify it NEW PW The new password desired 6 3 8 Secure Front Panel Security Lock The DSPSeries unit enables the user to secure the unit and prevent undesired changes in the...

Page 19: ...10 Eth GW Ethernet gateway The gateway address of the network usually the IP address of your router switch or hub This parameter is only available when the Ethernet card accessory is installed 6 3 11...

Page 20: ...Type XOver TYPL Off Butterworth Linkwitz Riley Bessel Xover Low Freq XOver FRQL 20 30k 1 Hz Xover Low Slope XOver SLPL 6 48 6 dB octave Xover High Type XOver TYPH Off Butterworth Linkwitz Riley Bessel...

Page 21: ...Ethernet with the optional Ethernet card For the USB connection a driver must be installed included with the DSPLink installation package For the Ethernet connection the IP address should be set as in...

Page 22: ...ord in the DSP unit and you don t remember it any more please take the following steps A Power on the device B During a few seconds an 8 character code is shown in the LCD display Write it down C Send...

Page 23: ...e 24 bit Propagation Delay 1 5 ms Front Panel Controls Display 2 x 16 Character Backlit LCD Level Meters 5 segment LED Buttons Mute Controls Menu Controls Dial Encoder Embedded Thumb Wheel Connectors...

Page 24: ...d 20 to 20dBu Attack 0 3 to 100ms Release 2 to 32X the attack time Ratio 1 1 to 1 40 Limiters 1 per Output Threshold 20 to 20dBu Attack 0 3 to 100ms Release 2 to 32X the attack time System Parameters...