3.1 General Specifications
3.1.1 Manual and auto range
3.1.2 Full range overload protection
3.1.3The maximum voltage allowed between the measuring
end and the earth:CAT IV measurement environment
for 600V DC or AC(RMS),CAT III measurement
environment for 1000VDC or AC(RMS).
3.1.4 Maximum working height: 2000m
3.1.5 Display:LCD
3.1.6 Maximum display value:6599
3.1.7 Polarity indication:“-” indicates negativepolarity
3.1.8 Overload indication:“0L” or “-0L”
3.1.9 Sampling frequency: 0.4s (digital display)/ 0.04s
(bar graph).For current readings, 1s (digital display)
/ 0.1s (bar graph)
3.1.10 Units display: functions and units
3.1.11 Auto power off: 15 minutes
3.1.12 Power supply: 9V 6F22 battery
3.1.13 Low battery indication: LCD displays“ ”
Temperature coefficient: less than 0.1x specified
accuracy/°C
Operating temperature:0°C
~40°C
3.1.16 Storage temperature:-10°C
~50°C
3.1.17 Dimensions:175×85×52mm
3.1.18 Weight:approx.420g(including battery)
3. Specifications
The Meter should be calibrated annually between
18°C~28°C and a relative humidity less than 75%.
Alternating current
Direct current
Diode
Continuity
Autoranging mode
Maximum value
Minimum value
Low battery
Percentage (duty cycle)
Hertz, Kilohertz (frequency)
Millivolt, Volt (voltage)
Micro amp, Milliamp, Amp (current)
Nanofarad, Microfarad, Millifarad
(capacitance)
Ohm, Kilohm, Megaohm (resistance)
Relative value
AUTO
MAX
MIN
%
Hz, kHz
mV, V
REL
Ω, kΩ, MΩ
nF, μF, mF
μA, mA, A
Auto power off
NCV
Non-contact voltage detection
Data hold