Mastech MS8233E User Manual Download Page 6

 

 
 

 

 

                                                                       

  Auto Power- OFF. : If the meter is idle for 15 minutes (idle time), the meter 

automatically turns the power off. After auto power-off, pushing any of the push 

button or changing the rotary switch can turn on the meter again. 

  NOTE: 

1

  After  auto  power  off  in  the  AC  mode,  if  changing  the  rotary 

switch to the DC mode, the Re-power on if disabled. 

                (2)    The  meter  enters  sleep  mode  after  quto  power  off.  If  press 

“HOLD” push button to re-power on in the sleep mode, the auto 

power off function is disabled. 

 

  Operating temperature & Humidity: 0 ~ 40

℃ 

(32 ~10

4 ℉

) &    < 80% RH   

 

  Storage temperature & Humidity: -10 ~ 50

  (14 ~ 122 

) &    <70%RH 

● Power Supply:  9V Battery(6F22 or 1604A Type) x 1pc. 
● Safety Class:  IEC 61010-1, 

CAT II 600V

  Dimension (L x W x H) & Weight:    140 x 67 x 30mm,    Approx. 112g 

Accessary: 

1.    K-type temperature probe[P3400]-----      1pc 

                      2.    User’s Manual ----------------------------      1pc 

                      3.    Test lead          ----------------------------      1set 

                      4.    9V    Battery    ---------------------------      1pc 

4-2. Electrical Specification 

  ( at 2

3±5℃; <75% RH)

 

 

4.2.1 DC Voltage 

  Range 

  Resolution 

            Accuracy 

200mV 

0.1mV 

±(

0.5% rdg + 2dgt

 

2V 

0.001V 

20V 

0.01V 

200V 

0.1V 

600V 

1V 

±(

0.8% rdg + 2dgt

 

  - 8 - 

* Over load protection:    SG(Spark Gap) used to protect that the voltage 

overred 1500V 

4.2.2 AC Voltage 

  Range 

  Resolution 

          Accuracy 

2V      (40Hz-

400Hz

0.001V 

±(

0.9% rdg + 3dgt

 

20V    (40Hz-

400Hz

0.01V 

200V (40Hz-

400Hz

)    0.1V 

600V (40Hz-200Hz) 

1V 

±(

1.2% 

rdg + 3dgt 

      * SG(Spark Gap) used to protect High voltage that is 

  over 1500V. 

4.2.3    Resistance   

  Range 

    Resolution 

          Accuracy 

200

Ω

 

0.1

Ω

 

±(

0.8% rdg + 2dgt

 

2k

Ω

 

0.001k

Ω

 

20k

Ω

 

0.01k

Ω

 

200k

Ω

 

0.1k

Ω

 

2M

Ω

 

0.001M

Ω

 

±(

1.0% rdg + 2dgt

 

20M

Ω

 

0.01M

Ω

 

 

4.2.4    Diode check 

  Range 

Resolution 

Function 

 

0.001V 

Will display the forward drop voltage. 

* Operating current

about 1mA 

* Open circuit voltage

about 1.48V 

                                      - 9 - 

Summary of Contents for MS8233E

Page 1: ...DIGITAL MULTIMETER MODEL MS8233E Users Manual ...

Page 2: ...d double insulation The meter with holster that is giving the main body though downsized high resistance against the shock of a drop Protection provided by the instrument will be impaired if used in a manner not specified by the manufacturer This operating instruction covers information on safety and caution Please read relevant information carefully and observe all the warnings and note strictly ...

Page 3: ...etermine that determine that the equipment is functioning correctly Note international Electrical Symbol Dangerous Voltage Ground AC Alternating current Warning see explain in manual DC Direct Current Double insulation AC or DC Fuse This product has been tested to the requirements ofC AN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating...

Page 4: ...ntinuity and HOLD Press HOLD to enter and exit the hold mode in any mode That act with trigger MAX This key is act with trigger Press this key once the maximum value is holding Will displays MAX symbol in the LCD After pressing the key A D will keep working and the display value are always up dated and kept the maximum value NOTE The actual gained value is not the peak value This key is used contr...

Page 5: ... Fahrenheit 9 µmVA mV V is unit of voltage µA mA A is unit of current 10 Indicate negative reading 6 Fig 2 LCD 4 Specification 4 1 General Specification Auto ranging DMM that full scale is 2000 counts Display 3 1 2 digit LCD display Over load protection Used the PTC protection circuit for Resistance temperature AC electric field detection function NCV function DATA HOLD function MAX value hold fun...

Page 6: ...H Weight 140 x 67 x 30mm Approx 112g Accessary 1 K type temperature probe P3400 1pc 2 User s Manual 1pc 3 Test lead 1set 4 9V Battery 1pc 4 2 Electrical Specification at 23 5 75 RH 4 2 1 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 rdg 2dgt 2V 0 001V 20V 0 01V 200V 0 1V 600V 1V 0 8 rdg 2dgt 8 Over load protection SG Spark Gap used to protect that the voltage overred 1500V 4 2 2 AC Voltage ...

Page 7: ...put terminal 4 2 7 AC Current 40Hz 400Hz Range Resolution Accuracy 200µA 0 1µA 1 5 rdg 4dgt 2000µA 1µA 20mA 0 01mA 200mA 0 1mA 10A 0 01A Over Load protection use the fuse F250mA H 250V at µA mA range and use the fuse F10A H 250V at 10A range 10 Max input current 250mA at mA input terminal and 10A at 10A input terminal 4 2 8 Temperature You can selecting Centi degree or Fahrenheit by FUNC key Range...

Page 8: ... 12 5 2 Resistance measurement The resistance range are 200 0Ω 2 000KΩ 20 00KΩ 200 0KΩ 2 000MΩ 20 00MΩ To measure resistance connect the meter as follows 1 Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal 2 Set the rotary switch to proper resistance range 3 Connect the test lead across with the object under testing The measured value will be show on the L...

Page 9: ... Press the FUNC key to enter to the continuity mode The buzzer sound if the resistance of a circuit under test is less than 100Ω 14 NOTE Input signal level must be higher than 0 5V it is sensitivity 5 4 DC AC µA or mA measurement DC Current range is 200 0µA 2000µA and 20 00mA 200 0mA and then 10A range AC Current range is 200 0µA 2000µA and 20 00mA 200 0mA and then 10A range 1 Turn off power to th...

Page 10: ...oltage in an electrical cricuit or equipment without touching them i e Non Contact Voltage detection NCV Detection against in wall outlet is possible The detecting position may be away about 20mm from the objet under check 16 6 Maintenance 6 1 Replacing the battery When meter display the battery must be replace to maintain normal operation Disconnect and remove all test probes from any live source...

Page 11: ...y 1000v CATII or 600V CAT III 10 A or better warning TO AVOID ELECTRICAL SHOCK REMOVE TEST LEADS BEFORE OPENING BATTERY COVER RISQUE DE CHOC ÉLECTRIQUE RETIRER CORDONS DE MESURE D OUVERTURE AVANT couvercle des piles 6 4 Cleaning and Decontamination The meter can be cleaned with soft clean cloth to remove any oil grease or grim Do not use liquid solvent or detergent 17 ...

Reviews: