3.1.17 Storage Temperature: -10°C to 50°C 
                                                   (10°F to 122°F)
3.1.18 Dimension: 110×76×11mm
3.1.19 Weight: approximate 100g (including battery)

3.2 Electrical Specifications

Circumstance Temperature: 23±5

°

C  

                   Relative Humidity: < 70%

3.2.1 Dc voltage

Range

Resolution

Accuracy

400mV

0.1mV

±(0.7% of rdg + 2digits)

4V

40V

400V

600V

1mV

10mV

100mV

1V

-

Input Impedance: 10M

- Max. Input Voltage: 600V DC or rms AC

NOTE:

At the little voltage range, the meter will show unsteady 
reading when test leads haven't reach the circuit, it's 
normal because the meter is very sensitivity. When test 
leads touch the circuit, you can get the true reading.

3.2.2 Ac voltage

Range

Resolution

Accuracy

±(0.7% of rdg + 2digits)

4V

40V

400V

600V

1mV

10mV

100mV

1V

-

Input Impedance: 10M

- Max. Input Voltage: 600V DC or rms AC
- Frequency Range: 40 to 1kHz
- Response: Average, calibrated in rms of sine wave

NOTE: 

At the little voltage range, the meter will show unsteady 
reading when test leads haven't reach the circuit, it's 
normal because the meter is very sensitivity. When test 
leads touch the circuit, you can get the true reading.

3.2.3 Resistance

Range

Resolution

Accuracy

±(1.2% of rdg + 2digits)

400

Ω

4k

Ω

40k

Ω

400k

Ω

0.1

Ω

1

Ω

10

Ω

100

Ω

4M

Ω

40M

Ω

1k

Ω

10k

Ω

±(2.0% of rdg + 5digits)

-

Open Circuit Voltage: 0.25V

- Overload Protection: 250V DC or rms AC

3.2.4 Capacitance

Range

Resolution

Accuracy

±(3.0% of rdg + 3digits)

4nF

40nF

400nF

4

μ

F

1pF

10pF

0.1nF

1nF

40

μ

F

200

μ

F

10nF

100nF

- Overload Protection: 250V DC or rms AC

Pocket Digital Multimeter 

Pocket Digital Multimeter 

Summary of Contents for MS8216

Page 1: ...User s Manual CAT II 600 V CAT III 300 V Pocket Digital Multimeter ...

Page 2: ...ood condition Before using verify that the insulation on test leads is not damaged and or the leads wire is not exposed 1 1 5 Full compliance with safety standards can be guaranteed only if used with test leads supplied If necessary they must be replaced with the same model or same electric ratings 01 1 Safety information 1 1 Preliminary 1 2 During use 1 3 Symbols 1 4 Maintenance 2 Description 2 1...

Page 3: ...ned fully 1 2 11 Please do not store or use meter in areas exposed to direct sunlight high temperature humidity or condensation 1 3 Symbols Note Important safety information refer to the instruction manual Earth ground TERMINAL Caution possibility of electric shock Equipment protected throughout by double insulation or reinforced insulation Application around and removal from UNINSULATED HAZARDOUS...

Page 4: ... Accuracy is specified for a period of year after calibration and at 18 C to 28 C 64 F to 82 F with relative humidity to 75 3 1 General specifications 3 1 1 It includes 7 function with 29 ranges 3 1 2 Auto ranges 3 1 3 Overrange protection for all ranges 3 1 4 Max Voltage Between Terminals And Earth Ground 600V DC or rms AC 3 1 5 Operating Altitude 2000 meters 7000 ft maximum 3 1 6 Display LCD 3 1...

Page 5: ...lution Accuracy 0 7 of rdg 2digits 4V 40V 400V 600V 1mV 10mV 100mV 1V Input Impedance 10M Max Input Voltage 600V DC or rms AC Frequency Range 40 to 1kHz Response Average calibrated in rms of sine wave NOTE At the little voltage range the meter will show unsteady reading when test leads haven t reach the circuit it s normal because the meter is very sensitivity When test leads touch the circuit you...

Page 6: ... 2 6 Duty cycle Range Resolution Accuracy 3 0 0 1 99 9 0 01 By Hz range Input Voltage range 0 5V 10V rms AC Input voltage must be enlarged with increasing frequency under measurement Overload protection 250V DC or rms AC Frequency Response 0 200kHz By V range Input Voltage range 0 5V 600V rms AC Input voltage must be enlarged with increasing frequency under measurement Input Impedance 10M Max Inpu...

Page 7: ...ll auto power off with five short sounds and one long After auto power off if stir the transform switch or put down any button of H D REL H D meter will recover the working condition 4 5 Preparation for measurement 4 5 1 Stir the transform switch If the battery voltage is less than 2 4V display will show the battery should be changed at this time 4 5 2 The besides the input lead shows that the inp...

Page 8: ...e capacitance of a capacitor Warning NOTE 1 It takes certain time 200μF range 30 seconds to steady the reading when measuring high capacity 2 When measuring low capacity range under the open circuit put down the REL to make the display show 000 then you might get reading from it 4 10 Measuring frequency 4 10 1 Set the transform switch at the Hz range position or at the ACV range and the DCV range ...

Page 9: ...e sure that the test leads have been clearly move away from the circuit under measurement before opening the battery cover of the meter 5 1 1 If the sign appears it means that the batteries should be replaced 5 1 2 Loosen the fixing screw of the battery cover and remove it 5 1 3 Replace the exhausted batteries with new ones Note Do not reverse the polarity of the batteries WARNING Do not mix old a...

Page 10: ...00 05 0918 ...

Reviews: