When the battery voltage drops below the operating

voltage, mark “

” appears and flashes. It must bedone to replace all batteries with new one.

When the DC adapter is used, insert the plug of the adapter into the DC 9V connector on the side

panel.

.

The method of usage

1.

Press the power switch, LCD displays the default

range(40~90dB). and displays the sound level of a spot. If the display appears “UNDER” or “OVER”

symbol, it indicates the sound level less than or more than 40~90dB, measurement is invalid. you need

to set the meter’s range to a correct position.

2.

Set range:

Press

LEVEL ▲ or ▼, choosethe proper range,

measure the sound level of the spot. When LCD appears “UNDER” symbol, it indicates that the range

is high, you need to press LEVEL▼ to set lower range until no “UNDER” symbol. When LCD

appears “OVER” symbol, it indicates that the range is low, you need to press LEVEL▲ to set higher

range until no “OVER” symbol.

3.

Choose weighting mode:

when you measure a general noise sound level, you could choose ‘A’ weighting bypressing A⁄C

button. To measure a acoustic sound level , choose “C”.

4.

When you want to get a real-time sound level, choose FAST by pressing FAST⁄SLOW button. To

get average sound level, choose “SLOW”.

5.

When you want to get the maximum value of a sound level, you can press “MAX” button.

6.

When you want to measure in the night, you can open the background light by pressing “LIGHT”

button.

Summary of Contents for MS6700

Page 1: ...ing to the following usage Environment conditions Altitude less than 2000 meters Relatively humidity 80 max Operation temperature 0 40 Maintenance save Do not clear the meter using alcohol and impregnant if you do not use it for a long time please take out the battery and place the instrument in a dry surrounding Safety symbols Meter is protected by double insulation Comply with European Union s 9...

Page 2: ... long time Ⅳ Specifications Accuracy 1 5dB Response frequency 31 5Hz 8kHz Dynamic range 50dB Frequency weighting A C Time weighting FAST 125ms SLOW 1sec Microphone Electret Condenser microphone Digital display 4 digitals resolution 0 1dB sampling rate 2 times s Analog bar display Each analog bar is as 1dB sampling rate 20 times s Measurement ranges 30 80dB 40 90dB 50 100dB 60 110dB 70 120dB 80 130...

Page 3: ...ge 9vDC Voltage ripple 100mVpp Supply Current 100mADC Socket pin Ground Casing positive External Diameter 3 5mm Operating temperature 0 40 Operating humidity 10 80 RH Storage temperature 10 60 Storage humidtiy 10 to 70 RH Dimensions 245 L 80 W 35 H mm Weight Approx 350g including battery Accessories Earphone plug Operation manual Battery Windscreen Ⅴ Preparation before using Remove the battery cov...

Page 4: ...he proper range measure the sound level of the spot When LCD appears UNDER symbol it indicates that the range is high you need to press LEVEL to set lower range until no UNDER symbol When LCD appears OVER symbol it indicates that the range is low you need to press LEVEL to set higher range until no OVER symbol 3 Choose weighting mode when you measure a general noise sound level you could choose A ...

Page 5: ... it normally a time for each year Calibration needs a standard sound source please contact with us about the method Ⅸ Cautious Do not use the meter in a high temperature or wet place When you do not use for a long time please take out battery to avoid damaging the meter by electrolyte Auto range 30 130dB is unfit for measuring a instantaneous and impactive noises To measure sound level in a windy ...