![Mastech MS5203 Manual Download Page 21](http://html1.mh-extra.com/html/mastech/ms5203/ms5203_manual_1736117021.webp)
Insulation Tester
19
MAX/
MAX/
MAX/
MAX/ MIN/AVG
MIN/AVG
MIN/AVG
MIN/AVG
The meter will record the max , min and average value automatically. The record time base is approx. 5 seconds. Press
SELECT to view the corresponding value.
DAR
DAR
DAR
DAR &
&
&
& PI
PI
PI
PI
Sometimes an insulation part with obvious drawbacks (e.g., the insulation part is broken through under high voltage) is
nevertheless with a good absorption ratio (or polarization index). Therefore, absorption ratio (polarization index) cannot
be used to discover local insulation drawbacks other than dampness and contamination.
R10Min= Resistance value measured 10 minutes after applying the test voltage; R1Min=R60Sec= Resistance value
measured 10 minutes after applying the test voltage; R15Sec= Resistance value measured 10 minutes after applying the
test voltage
After performed insulation test,press SELECT button to view DAR or PI .If DAR or PI Value invalid, the meter display - -
- - .
DAR
(
absorbing ratio
)
=
Sec
R
Sec
R
15
60
PI(
polarization index
)
=
Min
R
Min
R
1
10