AC Leakage Current Clamp Meter
Instruction Manual
1. Safety information
The meter is a handheld and battery operated Digital AC Clamp
Meter with multi function. This clamp meter has been designed to
meet IEC1010-1 and CAT III over Voltage category.
1-1.Safety cautions
•
User must be read the operating instructions thoroughly and
completely before operating your meter. Pay particular attention
to WARNING, which will inform you of potentially dangerous
procedures.
•
Do not apply more than the rated voltage ,of marked on the meter,
between the “INPUT” terminal and “COM” terminal.
•
Do not expose the instrument to direct sunlight, extreme
temperature and moisture or dew full.
•
You always are careful when working with voltage above 60V DC
or 30V AC rms.
•
Keep fingers behind the clamp barrier while measuring current..
•
Always inspect the test lead for damaged insulation or exposed
metal.
01
02
03
04
05
Warning
To avoid possible electric shock or personal injury and possible
damage to the meter or the equipment under test, you are must
be adhere to the following rules.
1-2. Symbols
Note international Electrical Symbol.
Dangerous Voltage
Ground
AC
(Alternating current)
DC (Direct Current)
Warning see explain
in manual
Double insulation
2-1 Panel description
1. Clamp jaw ; it is as current transformer(CT) when measuring
current flowing through the conductor .
2. Trigger
3. Clamp Barrier:
4. LCD display
5. “
HOLD
” button
When push this button, the display will keep the last reading.
Once push again, the Meter will return the normal mode.
6. Knob: it is rotary switch for select function.
7. “
MAX
” button
8. “
RANGE
” button
9. “
FUNC
” button
10. “
LPF
” button
11. “
INPUT
” terminal
12. “
COM
” terminal
13. “
*
” Back Light push button
Alternating current
Directive current
Diode
Continuity
Auto ranging mode
Maximum value measurement mode
Low pass filter is act
Low pass filter is non act
Data hold mode
Low battery
2-2. LCD display
•
Auto
ranging
Digital
Clamp
Meter. But
the
meter
may
select
manual Function
mode
by
“
RANGE
” button.
•
3
1/2
digit (200
count) LCD
display
•
Over
load
indication: “
OL
” symbol
will
displayed
on
the
LCD.
•
Jaw
opening
capability: 32mm
•
Low
battery
indication: battery
symbol
is
appears
on
the
LCD.
•
Auto
power
OFF: If
the
meter
is
idle
for
more
than
15
minutes,
the
meter
automatically
turns
the
power
off
.
•
Sampling
rate: 2 times/s
•
Power
supply: 1.5V
battery (AAA
type) x
3pcs
.
•
Operating
temperature & Humidity: 0°C to
40°C; <80%
•
Storage
temperature & Humidity: -10°C to
50°C; <70%RH
•
Dimension (L
x
W
x
H) & Wight
:
260
x
92
x
55mm;
Approx
.
400g
3. Specification
3-1. General feature
3-2. Electrical Specification
[1] AC Current
Range
20mA
200mA
2A
20A
200A
Resolution
0.01mA
0.1mA
1mA
10mA
100mA
Accuracy
(50 ~ 60Hz)
±(1%rdg+8dgt)
(30~50Hz,60~10KHz)
±(3%rdg+10dgt)
600A
1A
AC
DC
AUTO
MAX
LPF
LPF
HOLD
2.
Meter illustration
±(1.5%rdg+3dgt)
Press 2 Sec
MAX
HOLD
FUNC
RANGE
OFF
600 A
600V
MAX 600V
CAT. III
AC CLAMP METER
MS2010A
HIGH SENSITIVE
Autorange
COM
INPUT
LPF
°C °F
mVA
%Hz
n
μ
F
kM
Ω
AUTO
LPF
DC
AC
HOLD
REL
LPF
2
20
20
200
V
600V CAT. lll
MAX 600A
AUTO-POWER OFF
mA
TEMP
Ω
A
°C °F
mVA
%Hz
n
μ
F
kM
Ω
AUTO
LPF
DC
AC
HOLD
REL
LPF