19
CV table
CVs may be used with Loco Address (L), switch address (S) or both (LS)
CV
Description
D L/W Range
Note
71 PWM for SW1 (A1+A2)
15 LW 0...15 15= full voltage
75 switch time opposite direction 1
0 LW
0...255
0=off
1...255 = time basis 0,25 sek
76 switch time opposite direction 1
0 LW
255 Decoder type
242
---
read only
Attachment 1: (CV 51, 52) – Special functions A1 + A2
Value
Application
Note
0
Continuous Operation
if both 0 = state storage
1..15
Continuous Symmetric Flashing
(Time Base 0,25 sec per unit)
16
Inverse Coupling with output F1
(Alternating flashing)
only in CV 52 (F2 to F1)
(Loco address mode only)
+32
increase time base to 2.0 sec.
Only with symmetric flash + Monoflop
+64
Short Term Function, Monoflop
(Time Base 0,25 sec per unit)
switches after reaching the time limit
Standard Switch Function
+ 128 Asymmetrical Flashing (1/3 ON – 2/3 OFF)
Loco address mode only
+192
Asymmetrical Flashing (2/3 ON – 1/3 OFF)
Loco address mode only
Attachment 2: Default values at reset
Resetvalue
11
1
17 18 29 31 32
3
0 128 128 0
1
16
15 16
242 242
22
41 42 51 52 61 62 71 75 76
1
2
67 67
1
1
15
0
0