3.SAFETY REGULATIONS

3.1 Precautions

Carefully read the Instruction and Maintenance Manuals
before starting up and using the machine.
The manufacturer declines any responsibility for dam-
ages to persons or things stemming from noncompliance
with the safety standards.

Carefully examine the safety panels applied to the
machine and follow their contents to the letter.

- Do not allow unqualified or inadequately trained personnel

to use the generator.

- Keep children or animals away from the generator when

it is running.

- Do not approach the generator with wet hands as it is

a potential source of electrical shock if improperly used.

- Do not perform any operations on the generator unless

the motor is off; tests which require the motor to be
running must only be performed by specialized
personnel.

 When the generator is connected

to an automatic start-up panel, before any tests or
maintenance can be performed, it must be locked out
- by selecting the BLOCK function - or disconnected
- by disengaging the connector.

- The exhaust fumes contain carbon monoxide and other

harmful substances; never run the unit in an inadequately
ventilated area.

- Do not run the unit in the vicinity of areas where there is

the risk of explosion or fire.

- Refuelling must only be performed when the engine is off.
- The unit is grounded using an adequate diameter copper

cable.

 When using the generator, bear in

mind that in wet or very damp places and in confined,
conductive spaces the following regulations must be
complied with:  Chap. 11, sect. IV of CEI regulation 64-8.

3.2 Grounding the unit

For user safety the unit must always be grounded paying
particular attention to the section of the cable used.
Connect the ground cable with the special terminal
located on the outlet panel (Fig. 4 Ref. 8). Make ground
connections following the table indicating the cable
sections to be used; these depend on the power rating of
the generator:

Power

KVA

1-10

10÷20 20÷40 40÷60 60÷80

Section mm²

5

20

30

40

50

4.SING THE GENERATOR

4.1 Preliminary checks

The first time the unit is started up after maintenance, a
good rule of thumb is always to make certain that:
- the oil is at the required level. This is done using the dip

stick (fig. 5 ref. 1): see table for the suggested oils.

-  the electrical devices are off so that the generator will

not start up under a load.

- the fuel pipes are in good condition and properly

connected.

- no electrical connections are in poor condition.

4.2 Start-up

Before starting up the generator, make certain that all
devices are off so as to prevent forcing the engine when it
is cold. Proceed with start-up by rotating the START key
(fig. 4 ref.10) clockwise one click. All the LEDs will light
up for approximately 2 seconds as the self-check is
performed. The battery recharge LED (fig. 4 ref. 15) and
the low oil pressure LED (fig.4 ref. 13) will then remain on.

Start up the unit by turning the ignition key clockwise all
the way; only release it when the engine has cut in.
However, in no case should the key be held down for more
than 5 seconds in an attempt to start up the engine.

All protections cut in 15 sec. after the unit is started up
and, in case of malfunction, the unit will shut down and a
warning light will go on indicating the malfunction.

Before turning on any of the devices, leave the engine
running without any load for at least five minutes. This will
allow it to reach operating temperature gradually thus
ensuring maximum engine life and preventing seizing.

4.3 Shut down

The unit is shut down by turning the ignition key  (fig. 4 ref.
10) all the way counter-clockwise.
Before shutting down the unit, it is advisable to let it run
for a few minutes without any load thus lowering the
temperature inside the engine and the alternator.

4.4 Hook up to the automatic control panel

The Silent series units are prepared for connection to an
automatic control panel able to automatically start up the
generator, to switch lines when line power cuts out and
switch back when the line voltage is returned.
In addition, the automatic control panel maintains the
charge in the generator start-up battery, even when the
generator is off.

Summary of Contents for SILENT 5001DM

Page 1: ...9002 DT Rev 1 S S 23 10 02 cod 41327 mase mase mase mase maseGENERA TORS I MANUALE USO E MANUTENZIONE GB USE AND MAINTENANCE MANUAL NL GEBRUIKS ENONDERHOUDSHANDLEIDING D GEBRAUCHSANWEISUNG UND WARTUNG...

Page 2: ...Technicalspecifications 23 3 Safety regulations 24 3 1 Precautions 24 3 2 Earthingthegenerator 24 4 Using the generator 24 4 1 Preliminary checks 24 4 2 Start up 24 4 3 Stop 24 4 4 Hook up to the auto...

Page 3: ...of contents for a quick guide to the various subjects The most important parts of the text are indicated in bold and are preceded by the symbols illustrated and described below Thisindicatesthatoperat...

Page 4: ...n 6 Connector for hook up to the automatic controlpanel 7 Single phasesocket 8 Terminalforgroundconnection 9 Three phasesocket 10 Ignition key 11 Engineprotectionmodule 12 Runningenginelamp 13 Low oil...

Page 5: ...8100 Voltage V 230 400 230 400 Frequecy Hz 50 50 50 50 Current A 20 6 6 28 2 11 7 Power factor cos f 1 0 8 1 0 8 Degree of protection IP ENGINE Type Model No of cylinders n Fuel Power supply HP Displ...

Page 6: ...NGTHEGENERATOR 4 1 Preliminary checks The first time the unit is started up after maintenance a good rule of thumb is always to make certain that theoilisattherequiredlevel Thisisdoneusingthedip stick...

Page 7: ...3 Magnetothermalcircuitbreakerstothelowvoltageoutlets these break the circuit whenever the voltage at a given outletishigherthanthenominalvoltageforthatparticular outlet 6 MAINTENANCE Allmaintenanceo...

Page 8: ...njector insert a few drops of oil inside the combustion chamber and manually rotate the drive shaft a few times reinstall the injector and close the suction and delivery openings 6 7 Table of schedule...

Page 9: ...Stop solenoid 19 DC alternator 20 Battery Fig 10 1 Rotor 2 Stator 3 Electronic voltage regulator 4 Hour counter 5 Voltmeter 6 Magnetothermal switch 7 Magnetothermal switch 8 Singol phase socket 9 Thre...

Reviews: