4
How to handle stainless steel and other materials
Stainless steel corrosion
Corrosion such as rust might be caused by chemical attack. Use only cleaning liquids which are suitable
for use with stainless steel. Take care when deciding on the concentration, temperature and exposure
time of the chemicals, to avoid chemical attack.
Non-galling material
This non-galling alloy is a nickel based, corrosion resistant material which was developed for use in
positive displacement pumps. It is listed in the 3-A Standards and is thereby accepted for use with
product exposed surfaces. Do not use in combination with highly concentrated nitric acid, for example,
during passivation of new stainless steel piping systems. In this case remove the rotor and the gate
during the passivation process to avoid damage or chemical attack. When removing the rotor, a double
mechanical seal or a quench with a lip seal is needed, and you should close the connections for the
flushing fluid with plugs to keep the liquid in the pump during the passivation process. Do not use a
concentration of more than 3% of nitric acid for the CIP cleaning fluid.
Handling of elastomers and plastic parts after the passivation process
Check elastomeric and plastic parts after passivation for chemical attack and replace them if necessary.
5
Information for returning pumps
In compliance with the regulations in your area concerning the control of substances hazardous to health,
you are required to declare the substances which have been in contact with product (s) you return to
MasoSine or its distributors. Failure to do so will cause delays. Please ensure that you email us this
information and receive a RGA (Returned Goods Authorisation) before you despatch the product(s). A copy
of the RGA form must be attached to the outside of the packaging containing the product(s).
Please complete a separate decontamination certificate for each product and attach it to the outside of
the packaging containing the product (s). A copy of the appropriate decontamination certificate can be
downloaded from the Watson-Marlow Limited website at www.wmftg.com.
You are responsible for cleaning and decontaminating the product(s) before return.
6
When you unpack your pump
Unpack all parts carefully, retaining the packaging until you are sure all components are present and in
good order. Check against the components supplied list, below.
Packaging disposal
Dispose of packaging materials safely, and in accordance with regulations in your area. The outer carton
is made of corrugated cardboard and can be recycled.
Inspection
Check that all components are present. Inspect components for damage in transit. If anything is missing
or damaged, contact your distributor immediately.
Components supplied
l
MasoSine Certa series sinusoidal pump, bare shaft
l
The technical datasheet identifying, describing and defining the
pump
l
Operating instructions
l
Blocking tool and socket adapter
Optional items
l
Coupling
l
Coupling guard
l
Drive
l
Foot plate
Optional special design
l
Flush systems
l
Guard master
l
Jacketing for heating and cooling
Storage
This product has an extended shelf life. However, plastic parts and elastomeric parts should be stored in
a cool, dry environment. Care should be taken after storage to ensure that all parts function correctly.
m-certa800-en-01