s e r v i c e   /   m a i n t e n a n c e

W a r r a n t y

Masimo warrants to the initial purchaser that each new pulse oximeter will be free from 
defects in workmanship or materials for a period of one (1) year from the date of purchase.  
Masimo’s sole obligation under this warranty is to repair or replace any product that Masimo 
deems to be covered under warranty with a repaired or a replacement pulse oximeter.

Batteries are not warrantied.

To request a replacement or repair of an instrument under warranty, contact Masimo for a 
returned goods authorization.  If Masimo determines that a product must be replaced or 
repaired under warranty, it will be replaced or repaired and the cost of shipment covered.  
All other shipping costs shall be the responsibility of the purchaser.

E x c l u s i o n s

This warranty does not extend to any product that has been subject to misuse, neglect or 
accident; that has been damaged by causes external to the product; that has been used 
in violation of the operating instructions supplied with the product.  The warranty does 
not extend to any product that has been connected to an unlicensed instrument system, 
modified accessories or any unit that has been disassembled or reassembled by anyone 
but an authorized Masimo agent.

THIS WARRANTY, TOGETHER WITH ANY OTHER EXPRESS WRITTEN WARRANTY 
THAT MAY BE ISSUED BY MASIMO IS THE SOLE AND EXCLUSIVE WARRANTY 
AS TO MASIMO’S PRODUCTS.  THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY 
ORAL OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
MASIMO SHALL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR 
CONSEQUENTIAL LOSS, DAMAGE OR EXPENSE DIRECTLY OR INDIRECTLY 
ARISING FROM THE USE OR LOSS OF USE OF ANY PRODUCTS.

E n d - u s e r   l i c e n s e   a g r e e m e n t

THIS DOCUMENT IS A LEGAL AGREEMENT BETWEEN YOU, THE “PURCHASER,” 
AND Masimo Corporation (“MASIMO”).  IF YOU DO NOT AGREE TO THE TERMS OF 
THIS AGREEMENT, PROMPTLY RETURN THE ENTIRE PACKAGE, INCLUDING ALL 
ACCESSORIES, IN THEIR ORIGINAL PACKAGE, WITH YOUR SALES RECEIPT TO 
MASIMO FOR A FULL REFUND.

1. 

Grant of License: In consideration of payment of the license fee, which is part 
of the price paid for this product, MASIMO grants to Purchaser a nonexclusive, 
nontransferable license, without right to sublicense, to use the copy of the incor-
porated software/firmware and documentation in connection with Purchaser's use 
of the Masimo Products for their labeled purpose.  MASIMO reserves all rights not 
expressly granted to Purchaser.

S e r v i c e   a n d   r e p a i r

REPAIR POLICY

Masimo or an authorized Service Department must perform warranty repair and service.  
Do not use malfunctioning equipment.  Have the unit repaired.

Please clean contaminated/dirty equipment before returning, following the cleaning 
procedure described in Section 9, 

Cleaning

.  Make sure it is fully dry before packing the 

equipment.

To return the Rad-8 unit for service, please follow the Return Procedure.

WARNING:

  AN OPERATOR MAY ONLY PERFORM MAINTENANCE PROCE-

DURES SPECIFICALLY DESCRIBED IN THIS MANUAL.  REFER SERVICING TO 
QUALIFIED SERVICE PERSONNEL TRAINED IN THE REPAIR OF THIS EQUIP-
MENT.

RETURN PROCEDURE

Please clean contaminated/dirty equipment before returning and make sure it is fully dry 
before packing the equipment.  Call Masimo at 800-326-4890 and ask for Technical Support.  
Ask for an RMA number.  Package the equipment securely – in the original shipping con-
tainer if possible – and enclose or include the following information and items:

  A letter describing in detail any difficulties experienced with the pulse oximeter.  

Please include the RMA number in the letter.

  Warranty information – a copy of the invoice or other applicable documentation 

must be included.

  Purchase order number to cover repair if the oximeter is not under warranty, or for 

tracking purposes if it is.

  Ship-to and bill-to information.

  Person (name, telephone/Telex/fax number, and country) to contact for any ques-

tions about the repairs.

  A certificate stating the oximeter has been decontaminated for bloodborne pathogens.

Return Rad-8 pulse oximeter to the following shipping address:

For USA:

For Europe:

For Asia Pacific:

Masimo Corporation
40 Parker
Irvine, California 92618
Tel: 949-297-7000
FAX 949-297-7001

Masimo Europe Limited
304 RN6, Le Bois des Cotes 2
69760 Limonest
France
Tel: +33 (0) 472 17 93 70
FAX: +33 (0) 478 35 78 08

Masimo Japan Corporation
World Times Bldg. 4F
10-7, Ichiban-cho, Chiyoda-ku,
Tokyo 102-0082  JAPAN
Tel: 03 3237 3057
FAX: 03 3238 1110

s e r v i c e   /   m a i n t e n a n c e

9-4

Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual

9

Summary of Contents for Rad-8

Page 1: ...Signal Extraction Pulse Oximeters OPERATOR S MANUAL...

Page 2: ...9 297 7001 www masimo com EU Authorized Representative for Masimo Corporation MDSS GmbH Schiffgraben 41 30175 Hannover Germany Tel 49 511 62 62 86 30 Fax 49 511 62 62 86 33 MEDICAL ELECTRICAL EQUIPMEN...

Page 3: ...If sensor is exposed to the irradiation the reading might be inaccurate or the unit might read zero for the duration of the active irradiation period Always remove the sensor from the patient and com...

Page 4: ...ory default settings 4 10 Setup Menu Level 3 Clear trend 4 10 t a b l e o f c o n t e n t s iv Rad 8 Signal Extraction Pulse Oximeter Operator s Manual Rad 8 Signal Extraction Pulse Oximeter Operator...

Page 5: ...the Rad 8 pulse oximeter appears before this introduction Other important safety information is located throughout the manual where appropriate Read the entire safety information section before you o...

Page 6: ...ort 8 hours Internal battery life with fully charged battery Serial output port Display capability on Philips Agilent monitor through Philips VueLink function RadNet TM and RadLink capability INDICATI...

Page 7: ...able to adapt to the varying physi ologic signals and or noise and separate them by looking at the whole signal and breaking it down to its fundamental components The Masimo SET signal processing alg...

Page 8: ...he bottom of the Rad 8 vertical Rad 8 family offers full Masimo SET technology in a small compact device Rad 8 family supports the full line of Masimo sensors and patient cables see Section 8 Sensors...

Page 9: ...rtical LED bar rises and falls with the pulse where the height of the bar indicates the quality of the signal 9 Saturation Display The functional arterial hemoglobin oxygen saturation is displayed in...

Page 10: ...er or packaging and are defined below SYMBOLS RS 232 Equipotential Ground Terminal Caution consult accompanying documents Nurse Call Interface WEEE compliant Defibrillation Proof see front panel Mark...

Page 11: ...er source CAUTION DO NOT CONNECT THE RAD 8 PULSE OXIMETER TO AN AC OUTLET CONTROLLED BY A SWITCH Verify the AC power voltage and frequency before use Verify that the power source can provide adequate...

Page 12: ...e front panel display is free of alarm and system failure messages see Section 5 Alarms and Messages 9 Verify the display shows the following Mode setting Standard Std or Sleep SLP or Home Hnn SpO2 Lo...

Page 13: ...DISABLED IN THIS MODE If the unit is connected to a RadNet system there will be no communication with RadNet in this mode 11 Verify that the patient alarms are functional by setting the high and low...

Page 14: ...ity of the readings over time is affected by the averaging mode being used The longer the averaging time the more stable the readings tend to become This is due to a dampened response as the signal is...

Page 15: ...rovides a visual indicator of the plethysmogram signal quality and an alert when the displayed SpO2 values are not based on adequate signal quality The signal quality indicator displayed on the Rad 8...

Page 16: ...ound and can be silenced for 120 seconds default by pressing the Alarm Silence Button Refer to Setup Menu Level 1 in this section to change setting If a low battery condition occurs while not monitori...

Page 17: ...rend memory while the device is turned on and the trend data remains in memory until the memory fills up or cleared by the user NOTE It is recommended that you clear the trend prior to performing a ne...

Page 18: ...ing choose the preferred settings by stepping through menu options Refer to Section 5 Output 2 Connect one end of the VueLink cable to the Serial Output connector on the back of the Rad 8 3 Connect t...

Page 19: ...e front panel of the oximeter The following sub sections describe each menu item in more detail The oximeter has options that allow user configuration to suit specific needs SPECIAL MENU STANDARD HOME...

Page 20: ...Sensor 100 reserved 200 reserved 400 Low Signal IQ 800 Masimo SET This flag means the algorithm is running is full SET mode It requires a SET sensor and needs to acquire some clean data for this flag...

Page 21: ...THE LIMITS EACH TIME THE PULSE OXIMETER IS USED An audible alarm and a flashing alarm status indicator will occur when an alarm limit is exceeded for greater than five seconds See section 4 Alarm Fea...

Page 22: ...taneously Return for service 5 a l a r m s a n d m e s s a g e s MESSAGES The Rad 8 will indicate other data or system errors Message conditions for the Rad 8 follow DISPLAY TYPE SOLUTION LEDS FLASH H...

Page 23: ...s Pulse Rate Accuracy Pulse rate 25 240 bpm No Motion1 Adults Pediatrics Neonate 3 digits Motion2 Adults Pediatrics Neonate 5 digits Low Perfusion3 Adults Pediatrics Neonates 3 digits Resolution Satur...

Page 24: ...lass B Equipment Classification IEC 60601 1 UL 60601 1 IEC 60601 1 1 Type of Protection Class 1 on AC power Internally powered on battery power Degree of Protection Patient Cable Type BF Applied Part...

Page 25: ...f monitoring For more information refer to the following table or contact your Sales Representative Use only Masimo SET sensors and sensor cables Select an appropriate sensor apply it as directed and...

Page 26: ...o L 3 kg 3 3 3 bpm 5 bpm 3 3 bpm 40 kg 2 3 3 bpm 5 bpm 2 3 bpm LNCS NeoPt L 1 kg 3 3 3 bpm 5 bpm 3 3 bpm SENSOR APPLICATION INSTRUCTIONS Unless indicated otherwise in the directions for use reposition...

Page 27: ...OLUTION DONOTSTER ILIZE ANY MASIMO SENSOR BY IRRADIATION STEAM OR ETHYLENE OXIDE M a s i m o S E T p a t i e n t c a b l e s Reusable patient cables of various lengths are available Only use appropria...

Page 28: ...ot allow liquids to enter the interior of the instrument Glutaraldehyde Solution Ammonium Chloride Wipe 10 Chlorine bleach in H2O 70 Isopropyl alcohol CAUTIONS DO NOT AUTOCLAVE PRESSURE STERILIZE OR G...

Page 29: ...ibed tests discontinue its use and correct the problem before returning the unit back to the user Before performing the following tests verify unit is connected to AC power Also disconnect any patient...

Page 30: ...part of the price paid for this product MASIMO grants to Purchaser a nonexclusive nontransferable license without right to sublicense to use the copy of the incor porated software firmware and documen...

Page 31: ...vative works based on the written materials without the prior written consent of MASIMO 6 Transfer Restrictions The software firmware is licensed to the Purchaser and may not be transferred to anyone...

Page 32: ...tion on both the sensors and monitors to ensure accurate pulse oximetry when needed most 2007 Masimo Corporation Masimo Signal IQ Discrete SaturationTransform DST Satshare SET FastSat Rad 8 Radlink Fa...

Reviews: