4.6. VU / GR 
 
This control switches the meter reading between: 

vu    Meter displays the output level. 

g.r.   Meter displays the average gain-reduction (dB). 

 
 

4.7. Compressor in/out 
 
This control switches the compressor, including input gain and output gain controls, in and out 
of circuit. 

out:   Compressor by-passed. Meter displays input amplitude in VU mode. 

in:  

Gain-reduction (compressor) circuit is active. 

 
 
 
4.8. Compressor indicator lamp 
 
This bi-colour indicator indicates if the compressor’s gain reduction circuit is active: 
 
Green   Indicates that the compressor is in circuit (on). 
 
Red  

The colour changes to red when the input signal causes gain reduction. 

 

This is particularly useful when the two channels are stereo linked, as the VU meters 
will not show which channel is causing the gain reduction (dominating). 

 

The light will also assist when the unit is located at a greater distance from the user. 

 

 

4.9. Stereo linking 
 
This switch enables the intelligent "Image-Link" system that matches the gain reduction 
applied to both channels. The linking is programme dependant

Momentary gain-reduction due to short duration peaks will not be linked. 
This technique maintains the integrity of the stereo image, while avoiding obvious pumping 
effects resulting from momentary transients on one channel. 

The ImageLink system is independent of all other controls. Different ratio, attack and release 
can be set to either channel. 

 

 
4.10. Threshold range 
 
This control is located on the rear panel and is designed to be pre-set at the time of 
installation. It selects between two ranges, ‘Normal’ for studio use and ‘High’ for Mastering 
use. 
In the ‘High’ setting, for a given audio programme the depth of compression will be less. 
The compression threshold is modified dynamically within these ranges by the MLA-2 control 
circuitry, according to programme content. 

Normal Threshold:   Threshold range -10.5 dBu to +14.5dBu 
High Threshold:  

Threshold range -1.5dBu to +23.5dBu 

 
 
 
 
 
 
 

Summary of Contents for MLA-2

Page 1: ...MASELEC MLA 2 Page 1 of 10 MLA 2 precision stereo compressor...

Page 2: ...f the behaviour of the device 2 SUMMARY OF MLA 2 FEATURES Operational Easy to operate with input gain controlling compression depth drive Minimal gain adjustment needed when changing ratio Optical gai...

Page 3: ...mains supply to the MLA 2 unit There is a main power switch on the rear of the unit and an auxiliary standby switch on the front which is more convenient to use if the equipment is rack mounted and t...

Page 4: ...rive principle and the control is called Input Gain The compression threshold is left unchanged while the input gain is adjusted to alter compression depth This has the advantage that gain and compres...

Page 5: ...entical set of controls A linking facility is provided that enables tracking of the two channels for stereo operation When selected stereo linking is intelligently controlled by the ImageLink system d...

Page 6: ...view of MLA 2 operation 4 3 Ratio This control adjusts the severity of the compression applied to loud signals i e those which exceed the compression threshold The MLA 2 automatically adjusts the thre...

Page 7: ...t a greater distance from the user 4 9 Stereo linking This switch enables the intelligent Image Link system that matches the gain reduction applied to both channels The linking is programme dependant...

Page 8: ...st also be screened The inputs are ground floating and both pin 2 and pin 3 must be connected 5 1 Output connections The outputs are electronically balanced and both pin 2 and pin 3 must be connected...

Page 9: ...d the screen on pin 1 Output impedance 33ohm pin 2 to pin 3 balanced Unbalanced output impedance 33ohm pin 1 to 2 or 3 6 3 Performance specification in out switches are illuminated and other settings...

Page 10: ...link connecting the audio ground to the chassis A chassis earth stud is provided on the rear of the unit 6 8 Physical dimensions Weight 10lb 5kg Width 19 inch 483mm rack mountable Height 2U 90mm Dept...