background image

IS 30 T

GB

4.2 Typical installation with generator above

the waterline

See Fig. 

3

1

Sea exhaust

2

Silencer

3

Muffler

4

Water filter

5

Main system tap

6

Sea intake

7

Drain tap

A

Pipes - inner diameter 75 mm

B

Pipes - inner diameter 25 mm

C

Pipes - inner diameter 16 mm

4.3 Typical installation with generator below

the waterline

See Fig. 

4

1

Sea exhaust

2

Silencer

3

Muffler

4

Water filter

5

Main system tap

6

Sea intake

7

Drain tap

8

Antisiphon valve

9

Drainage

A

Pipes - inner diameter 75 mm

B

Pipes - inner diameter 25 mm

C

Pipes - inner diameter 16 mm

D

Pipes - inner diameter 14 mm

• It is very important to respect the distances shown in

the installation diagrams.

• The mufflers, (Fig. 3 and 4, ref. 3), have the function

of collecting the water left in the exhaust pipes when

the generator engine is turned off and preventing that

it flows into the engine through the manifold and the

exhaust valve.  For this reason it is essential to respect

the position of the muffler and the length of the pipes

as indicated in the installation diagram.

4.4 Components

The sea water intake system must be separate from the

one for the engines propelling the boat.

Direct sea intake 1/2"

.

If the unit is installed more than 1 m above the water-

line, a check valve should be fitted after the sea intake,

(Fig. 5, ref. 1), to prevent the water circuit emptying when

the motor is off.  If this empties, the rotor of the water

pump might be damaged during start up; for the same

reason, when the unit is first started up, the suction tube

from the valve to the pump should be filled manually.

Ball tap 1/2"

, (general).

Ball tap 1/2"

, (drainage).  This is used to drain the

cooling system of the electric generator for general

maintenance or when a long period of inactivity is

expected.

Water filter

, (can be inspected).  This must provide

efficient protection for the cooling circuit from the

entrance of mud, sand and seaweed.

Rate of flow: 

25 l/min

.

The filter mesh should be very fine.  Mesh 2 - 470 micron

is recommended; other sizes do not give good filter

performance.

Anti-siphon valve

.  This is a valve that brings the

cooling circuit back to atmospheric pressure when

the motor is turned off, thus avoiding the formation

of siphons.  

It’s use obligatory when the base of

the generator group is under the water line

 and it

must be positioned at least 

50 cm

 above sea level,

(see Fig. 

4

).

Anti-siphon valve must be inserted between the inlet of

the sea water pump and mixing elbow as indicated  in

Fig. 8.

The drainage duct of the anti-siphon valve must run

beneath the valve itself in order to prevent water

accumulating in the duct, which should always remain

empty to allow air to pass through when the unit is

switched off, (see Fig. 6).

It is recommended that the drainage pipe from the anti-

siphon valve be fed into the bilge, as small amounts of

water might be drained through it during normal

operation.

Run the pipes connected to the antisiphon valve through

the holes shown in Fig. 

2

, ref. 

2

.

Summary of Contents for IS 30T

Page 1: ...GB INSTALLATION MANUAL IS 30 T 50 Hz...

Page 2: ...IS 30 T Fig 1 Fig 2 83 0 1460 675 B B A 2 Fig 3...

Page 3: ...IS 30 T Fig 7 Fig 6 Fig 5 Fig 8 Fig 4 2 1 Valvola antisifone Anti siphon valve Soupape antisiphon Beluchter...

Page 4: ...IS 30 T Fig 12 Fig 10 Fig 9 2 3 1 4 1 2 3 2 1 Fig 11...

Page 5: ...IS 30 T Fig 13 Wiring diagram STANDARD version...

Page 6: ...IS 30 T Fig 14 Wiring diagram RINA version...

Page 7: ...Ventilation 21 4 COOLING WATER CIRCUIT 21 4 1 Sea water feed system 21 4 2 Typical installation with generator above the waterline 22 4 3 Typical installation with generator below the waterline 22 4 4...

Page 8: ...onomy and a longer life of the generator It is warmly recommended to carefully read the contents of this manual and the reference documents only thus can regular functioning and reliability of the gen...

Page 9: ...equipped with an internal forced cooling system by means of the alternator fan The quantity of air required for alternator cooling and engine combustion is aspirated through the opening shown in Fig 2...

Page 10: ...he rotor of the water pump might be damaged during start up for the same reason when the unit is first started up the suction tube from the valve to the pump should be filled manually Ball tap 1 2 gen...

Page 11: ...the indicated It should be connected to the terminal of the generator Fig 9 ref 4 with cables of section 25 mm2 up to distances of 5 m and with cables of section 35 mm2 for longer distances and follo...

Page 12: ...is equipped with a magnetothermal switch which cuts the power in the event of an overload or short circuit Table of characteristics 6 4 Generator mains switching A switch should be placed on the line...

Page 13: ...gauge instrument 28 Remote control panel kit with instruments optional 29 Remote control panel kit standard equipment 8 2 RINA version See Fig 14 1 Magnetothermal switch 2 Hour counter 3 Alternator 4...

Reviews: