User’s Manual - The FT Series Wall Mounted, Combination Boiler

Page 3

#

    Name of Component

1

Air Vent (air eliminator)

2

Pressure Relief Valve

3

Air Intake Collar

4

Air Gas Mixing Pipe

5

Gas Valve

6

DHW Water Tank

7

Main PCB

8

Manual Power Switch (ON / OFF)

9

Recirculation Pump DHW / CH Primary Pump

10

'CH' Supply Connection

11

'CH' Return Connection

12

CH Pressure Gauge

13

DHW Outlet Connection

14

Gas Inlet Connection

15

DHW Inlet Connection (filter and flow restrictor)

#

    Name of Component

16

Condensate Connection

17

Condensate Trap

18

Air Pressure Switch (condensate)

19

Mixing Valve

20

Terminal Block

21

Control Panel and Display

22

Heat Exchanger

23

Ignition Trans

24

Flame Detecting Sensor

25

Burner Case

26

BLDC Fan

27

Vent Pipe

28

 Air Pressure Switch

29

Vent Pipe Collar

30

Sight Glass

Hydronic Supply

Hydronic Return

30

Summary of Contents for FTCW series

Page 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Page 2: ...lock a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild detergent Do not use flammable cleaning materials If sidewall vented...

Page 3: ...ction 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor Name of Component 16 Condensate Connection 17 Con...

Page 4: ...ons Temperature Specifications Operating ambient Temperature Range 10 to 60 C Operating Relative Humidity up to 90 at 40 C Shipping Storage Temperature Range of 20 to 80 C Buttons Functionality PRESS...

Page 5: ...Numeric Display Number and character display to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numer...

Page 6: ...ll go through a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Opera...

Page 7: ...t temperature I St N A Not Used Default is 0 J oH Overheat temperature Current Overheat temperature L rt 1 PH Burner Opera tion Time Supply power time Supply power time x 100 hour 2 rh Burner operatio...

Page 8: ...rn dial E clockwise to increase and counterclockwise to decrease until desired temperature is reached Press dial E to save setpoint changes and to Exit Indicate Example Current DHW set point temperatu...

Page 9: ...rol Display and Operation 5 6 CH Set Point Change Mode Changing between Celsius and Fahrenheit When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To chan...

Page 10: ...Page 10 Notes...

Page 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Page 12: ...cations subject to change without notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester...

Reviews: