11
INDICATOR:
FLASHING YELLOW
INDICATOR: GREEN
Charge Current
INDICATOR: YELLOW
Charge Voltage
Battery Voltage
Cut-Off Current
Step 2
CV Charge (max1 h)
Safety Timer (72 hours)
Step 3
Charge complete
Step 0
Start Timer
(10 min)
Step 1
CC Charge
Start Current
Low
Current Start-Up at Vbatt <3V/cell
Error Mode if <3V/cell after 10 minutes
Diagram: D
No voltage,
no current
from charger!
Battery Voltage
No current (0A)