background image

                                                                                                                                                                           

 

 

TABLE OF CONTENTS

 

 

 

 

 

 

     

 

 

           Page No 

Introduction  

 

 

 

 

1. Important Safety Precautions  

 

 

2. General  

 

 

 

 

3. Safe Operating Conditions    

 

   

4. Technical Information 

 

                 

5. Transport and Storage 

 

 

   

6. Assembly/Installation 

 

 

 

6.1. Installation 

 

 

 

   

6.2. Type of Connection 

 

 

   

6.3. Foundation   

 

 

   

6.4. Coupling Alignment 

 

 

   

6.5. Piping 

 

 

 

                5 

6.6. Motor Connection 

  

 

   

7. Commissioning ,Start Up And Operating 

   

7.1. Preparations Before Start-Up 

                 

7.2. Checking the Direction of Rotation 

 

7.3. Start-Up Procedure 

 

 

 

7.4. Shut Down Procedure   

 

 

8. Maintenance 

 

 

 

 

8.1. Checking During Operation 

                 

8.2. Service 

 

 

  

                8 

8.3. Spare Parts   

 

 

 

9. Noise Level and Vibration   

 

 

10.  Disasembly, Repair and Reassembly 

 

8  

11.  Possible Breakdown And Solution Methods    

12. 

Pump Dımensıons Table and Weıghts 

 

10 

13. 

Tıghtenıng Torques 

 

 

 

10 

14.  Forces and Moments at the Pump Flanges 

 

11 

15.  YPSP Sectional Drawing and Part List 

 

12 

16.  YPSP Series Pump - Exploded View 

  

13 

 

INTRODUCTION

  

 

 

  This  manual  contains  instructions  for  the  installation,  operation  and 

maintenance of the horizontal split case pumps of 

MAS DAF MAKİNA 

SANAYİ A.Ş.

 

  Please  read  carefully  this  manual  and  apply  all  the  instructions  to 

operate  pumps  without  problems.  Pumps  shall  be  used  for  their 
intended  duties.  In  this  manual,  there  are  information  on  operating 
conditions,  installation,  starting-up,  settings  and  main  controls  of 
pumps.  

  These  operating  and  maintenance  instructions  contain 

MAS  DAF 

MAKİNA  SANAYİ  A.Ş

.`s  suggestions.    The  special  operating  and 

maintenance information of the plumbing that a pump is fitted to is not 
considered in these instructions.  This information must be given by the 
plumbing constructors only.    

 

Please refer to instructions of plumbing constructors. 

  Please pay attention to the warnings in this manual and ensure that it is 

read  before  the  installation-start  up  process.   

MAS  DAF  MAKİNA 

SANAYİ  A.Ş.

  is  not  responsible  for  the  accidents  resulting  from 

negligence.  

  If  you  cannot  find  an  answer  to  your  questions  in  this  manual,  it  is 

suggested that you contact 

MAS DAF MAKİNA SANAYİ A.Ş

.  Please 

inform us about the rated value and especially   the serial number of the 
pump when you get in contact for help 

  The  safety  instructions  in  this  manual  cover  the  current  national 

accident protection regulations. Beside all of these, an operation, work 
and safety measure imposed by the costumer has to be applied 

 
The Signs Used in This Operation Manual 

 

 

   

                     

 

                     

 

 
                                      

 

1.  IMPORTANT SAFETY PRECAUTIONS

 

 

In  order  to  minimize  the  accidents  during  the  mounting  and  putting  into 
service of the pump, the following rules have to be applied: 
 
1.  Do  not  work  without  taking  safety  measures  relevant  to  equipment. 

Cable, mask and safety band must be used when necessary.  

2.  Be  sure  there  is  adequate  amount  of  oxygen  and  there  is  no  toxic 

gaseous around 

3.  Before  using  welding  or  any  electrical  equipment  make  sure  that 

there is no risk of explosion. 

4.  Check  the  cleanliness  of  the  area  to  take  care  of  your  help.  (Dust, 

smoke, etc.) 

5.  Do  keep  in  mind  that  there  is  a  risk  of  having  accidents  related  to 

electricity  

6.  Do not lift the pump before you check the transport equipment.  
7.  Be sure you have a by-pass line  
8.  Use helmet, eye glasses and protective shoes for your safety 
9.  Place  a  protective  barrier  around  the  pump  within  the  necessary 

safety area 

10.  Dust,  liquids  and  gaseous  that  may  cause  overheating,  short  circuit, 

corrosion and fire must be kept away from the pump unit. 

11.  By checking the noise level of the pump unit, necessary measures to 

avoid  noisy  operation  of  the  pump  that  can  have  harmful  effects  on 
the personel and environment. 

12.  Be careful about the direction of transport and storage.  
13.  Cover  appropriately  the  moving  parts  to  avoid  possible  injury  of  the 

personnel.    Mount  the  coupling  guard  and  belting  before  starting-up 
the pump 

14.  All  the  electrical  and  electronic  applications  must  be  performed  by 

authorized  person  conforming  EN60204-1  and  /or  domestic 
instructions. 

15.  Protect the electrical equipment and motor against overloading  
16.  If flammable and explosive liquids are pumped, ground connection of 

electricity should be carried out properly 

17.  Do not expose the pump unit to sudden temperature variations  
18.  All  personnel  who  work  with  the  waste  water  system  need  to  be 

vaccinated in case of contagious diseases. 

19.  If  the  pump  contains  hazardous  liquids,  one  must  use  protective 

helmet  against  the  risk  of  splatter.  One  also  must  accumulate  the 
liquid in a proper container against any risk of leakage.  
 

All Other Health and Safety Rules, Laws and 

Regulations Must Be Applied 

 

2. GENERAL

 

 
2.1. Definition of Pump and Usage Areas 
 

YPSP series pumps are split case horizontal pumps. They are used in  

  Irrigation pump stations, 

  Cooling water and circulation circuits  

  Tap water pump stations 

  Oil transmission pipeline stations,  

  Various pumping stations for general purpose.  

 

They  must  be  used  to  transfer  non-abrasive  and  non-flammable,  clean 
liquids (up to 90

0

C ) which do not contain large solid particles. 

 

 

 

CAUTION 

 

Please contact MAS D

AF MAKİNA SANAYİ A.Ş. for liquids that have 

different chemical and physical specifications

 

Technical specifications of YPSP type pumps 

 
Suction Flange 

 

: DN 80-DN 400 

Discharge Flange   

: DN 65-DN 350 

Operating Pressure  

: 16-20 Bar 

Capacity   

 

: 30-3000 m

3

/hour 

Head 

 

 

: 15-160 m 

Speed 

 

 

: 960-3600 rpm 

 

 
 
 
 
 

Read  the  instructions  carefully  in  this  operating 
manual and keep it for your future reference

Warning sign against the electrical risks   

Sign for the operator’s safety. 

Kullanıcı  güvenliği için ikaz işareti  

Summary of Contents for DAF YPSP 100-250

Page 1: ...Revision No 02 July 2018 Double Suction Horizontal Centrifugal Fire Pump YPSP SERIES OPERATING MANUAL...

Page 2: ...iteleri Related Directives Y netmelikler 2006 42 EC Machinery Directive 2006 42 AT Makine Emniyeti Y netmeli i 2014 35 EU Low Voltage Directive 2014 35 AB Al ak Gerilim Y netmeli i 2014 30 EU Electrom...

Page 3: ...t be used when necessary 2 Be sure there is adequate amount of oxygen and there is no toxic gaseous around 3 Before using welding or any electrical equipment make sure that there is no risk of explosi...

Page 4: ...DAF MAK NA SANAY A is not responsible for this kind of damages 3 2 Hazardous conditions that may occur when one does not comply with the safety instructions Incompliance with safety regulations may p...

Page 5: ...must be applied Please use a suspension system shown in figure while you are carrying and lifting the pump unit The suspension rings may be broken because of the excessive load and may result in a da...

Page 6: ...allows pinpointing the misalignments In order to avoid overheating vibration noise and wearing of the rolling bearings alignment of the coupling has to be made properly and checked often Do not use a...

Page 7: ...tant that pipe diameter and fittings are at least as much as the pump opening diameter or preferable one or two size higher One should never use fittings with smaller diameters than the pump exit diam...

Page 8: ...Electrical equipments terminals and the components of the control systems may carry electric current even though they are not operating They may cause deadly and serious injuries or irreparable materi...

Page 9: ...8 1 Checking During Operation Pump must never be operated without water Pump must not be operated for a long time with the discharge valve closed zero capacity Bearing temperature must never exceed 8...

Page 10: ...essure Level dB Pump with Motor 1450 rpm min 2900 rpm min 0 55 63 64 0 75 63 67 1 1 65 67 1 5 66 70 2 2 68 71 3 70 74 4 71 75 5 5 72 83 7 5 73 83 11 74 84 15 75 85 18 5 76 85 22 77 85 30 80 93 37 80 9...

Page 11: ...res are high Worn out coupling Too much too little or improper lubrication Increase in axial forcing Replace the coupling Change the oil decrease or increase its quantity Clean the balance holes on th...

Page 12: ...150 400 400 200 600 500 475 400 730 875 515 10 YPSP 150 500 450 250 650 550 550 500 870 1050 590 11 YPSP 200 315 250 200 972 427 545 430 205 430 360 500 400 450 375 735 825 565 12 YPSP 200 400 600 500...

Page 13: ...M x M y M z M x YPSP 65 250 100 65 1276 1029 1143 800 648 705 476 552 667 419 457 571 YPSP 80 250 125 80 1505 1219 1352 952 781 857 571 724 800 438 495 610 YPSP 80 360 YPSP 100 250 150 100 1905 1543...

Page 14: ...05 Casing Ring 201 Roller Bearing 25 Double Suction Impeller 210 Impeller Key 30 Bearing Housing 211 Coupling Key 34 Bearing Cover Coupling Side 240 Soft Packing 50 Stuffing Box 260 Plug 55 Gland 270...

Page 15: ...30 Bearing Housing 260 Drain Plug 34 Bearing Housing Cover 300 Stud 39 Supporting Foot 301 Stud for Gland 50 Stuffing Box 302 Stud 54 Gland 320 Hexagonal Bolt 56 Lantern Ring 321 Hexagonal Bolt 60 Pu...

Page 16: ...o 17 Tuzla STANBUL TURKEY Tel 90 216 456 47 00 pbx Fax 90 216 455 14 24 Ankara Regional Directorate A a ve ler Mah 1329 Sok No 6 9 ve ler ANKARA TURKEY Tel 90 312 472 81 60 67 Fax 90 312 472 82 51 Fac...

Reviews: