background image

NOTE

Ice-maker operation

The unit must be installed level for proper
ice-maker operation.

The shutoff arm wire must be down in its
lowest position for the ice-maker to operate.

When the freezer section and ice-maker unit

harvest ice cubes automatically.

When the ice bucket is full, the ice-maker will
automatically shut off.

You may manually stop the ice-maker by
raising the shut off arm to the locking position

Arm down, ice-maker 

will operate

Arm up, 
stops operation

Figure 8

When operation of the appliance is to be discon-
tinued for any length of time, the ice cube mold in 
the ice-maker should be emptied by allowing the 
ice-maker to dispense cubes with the water supply 
turned off. 
1.

Turn the water supply off.

2.

Raise the ice-maker bail arm.

3.

Empty the ice bucket.

4.

Replace the ice bucket in the unit and lower
the bail arm.

Dispensing of the cubes should occur within 2 
hours. After the ice-cubes dispense - empty, clean, 
and replace the ice cube bucket, and raise the bail 
arm. 

ICE-MAKER OPERATION

!

CAUTION

The water supply to the ice-maker must be turned 
on prior to turning the ice-maker on. Failure to do 
so will cause rapid dry cycling of the ice-maker 
mold heater resulting in temperature control issues 
in the freezer compartment.

It is recommended the ice-maker is shut off when 
removing the bucket, or ice may be dispensed onto 

If the ice is not used regularly, it will clump together 
with time. For best ice results, discard ice in the bin 
as required and allow the ice-maker to make a new 
fresh batch of ice. Shut-off the ice-maker by raising 
the shut-off arm before removing the bucket.

Long and short term storage of 
ice-maker:

8

Summary of Contents for MLVB224

Page 1: ...OWNERS GUIDE MARVEL OUTDOOR UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M O R F 2 2 4...

Page 2: ...w home Send us photos at marketing marvelrefrigera tion com and we might feature your Marvel home design on our website and social media XXXXXXXXXXXX XXXXXXXXXXXX MARVEL g Figure 1 R600A WELCOME It is...

Page 3: ...pliance Electrical Installing The Water Supply Maintenance Care and Cleaning Stainless Steel Maintenance Operating Instructions Ice Maker Operation Interior Adjustments Energy Savng Tips Service Obtai...

Page 4: ...em free installation and operation WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition 65 Warning This product contai...

Page 5: ...lace The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packaging until your appliance...

Page 6: ...rrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of t...

Page 7: ...gth and coil it behind the unit to form a service loop which will allow the appliance to be pulled out from the installation for servicing or cleaning Connect the copper tubing to the top side of a co...

Page 8: ...aise the ice maker bail arm 3 Empty the ice bucket 4 Replace the ice bucket in the unit and lower the bail arm Dispensing of the cubes should occur within 2 hours After the ice cubes dispense empty cl...

Page 9: ...ng the shelf To Add or Remove a Shelf Remove stored product from the shelf Do not try to remove a loaded shelf from the appliance Grasp the shelf front with both hands rotate the install a shelf inser...

Page 10: ...cuit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize door openings...

Page 11: ...upon the installation location environmental and usage conditions Choosing a Cleaning Product The choice of a proper cleaning product is ultimately that of the consumer and there are many products fro...

Page 12: ...rsonal preference and provides the proper storage for your stored contents 11 When on vacation or away from home for extended pe riods set the appliance to warmest acceptable tem perature for the stor...

Page 13: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Page 14: ...r and part description Some parts will require color or voltage information If Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be no...

Page 15: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Page 16: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Page 17: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Page 18: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Page 19: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Page 20: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Page 21: ...nvironment When in this mode the only functions will be the control and cabinet lights The compressor fans etc will not operate To enter exit this mode hold the light key and the power key for 5 secon...

Page 22: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Page 23: ...DQJH ZLWKRXW QRWLFH 6XFK UHYLVLRQV GR QRW HQWLWOH the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com 1...

Reviews: