Marvel MLBV215 Owner'S Manual Download Page 17

IA 

WARNING 

Only skilled and well trained service technicians 
permitted to service R-600a equipped products. 

All tools and equipment must be approved for 
use with R-600a refrigerant. 

Local, state and federal laws, standards must be 
observed along with proper certification and 
licensing. 

Ventilation is required during servicing. 

No conversions to R-600a from any other 
refrigerants.  OEM R-600a equipped unit only. 

Service area must be free of ignition sources. 

No smoking is allowed in the service area. 

All replacement electrical components must be 
OEM and installed properly  (sealed and 
covered). 

If the evaporator is cold prior to service, it must 
be thawed prior to service. 

When using a vacuum pump, start pump before 
opening refrigeration system. 

Vacuum pump and recovery equipment should 
be at least  10 feet from the work area. 

It is recommended that a simple LPG gas 
detector is on site during service. 

Ensure that all R-600a is removed from the 
system prior to brazing any part of the sealed 
system. 

Only a clean, dry leak free system should be 
charged with R-600a. 

R-600A Specifications

R-600A SPECIFICATIONS/LABELING

R-600a equipped products are labeled  (both the unit and
the compressor).

R-600a is colorless and odorless.

R-600a is considered non-toxic,  but is flammable when
mixed with air.

Do not remove or alter any R-600a labeling on the 

product. 

Use only a refrigerant grade R-600a from a properly 

labeled container. 

RECOVERING/RECLAIMING R-600A 

(R-600a has been exempted from recovery/reclaiming 

requirements by the  US  EPA) 

Recovery/Reclaiming equipment must be approved for use 
with R-600a. 

Ensure the evaporator is at room temperature prior to 

recovery /reclaiming R-600a. 

Use a common piercing pliers or piercing valve to remove 

R-600a from the compressor process tube.  (Note:  Piercing
devices must not be lelt on the system and must be
replaced with a Schrader type valve.)

17

Summary of Contents for MLBV215

Page 1: ...I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M L R E 2 2 4 OWNER S GUIDE MARVEL UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R AT I O N E X...

Page 2: ...marketing marvelrefrigera tion com and we might feature your Marvel home design on our website and social media Thank you again for investing in Marvel for your home XXXXXXXXXXXX XXXXXXXXXXXX MARVEL...

Page 3: ...Your Appliance Electrical Maintenance Care and Cleaning Stainless Steel Maintenance Extended Non Use Operating Instructions Interior Adjustments Energy Savng Tips Service Obtaining Service Product Li...

Page 4: ...nd care must be exercised when installing maintaining or operat ing this appliance Recognize Safety Symbols Words and Labels WARNING WARNING You can be killed or seriously injured if you do not follow...

Page 5: ...lace The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packaging until your appliance...

Page 6: ...rrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of t...

Page 7: ...ver shelf is secure on the shelf supports by pressing down on the shelf before loading the shelf CAUTION Grasp the shelf by the front with both hands and rotate the front of the shelf up then lift the...

Page 8: ...rcuit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize door openings...

Page 9: ...upon the installation location environmental and usage conditions Choosing a Cleaning Product The choice of a proper cleaning product is ultimately that of the consumer and there are many products fro...

Page 10: ...rsonal preference and provides the proper storage for your stored contents 11 When on vacation or away from home for extended pe riods set the appliance to warmest acceptable tem perature for the stor...

Page 11: ...low ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minim...

Page 12: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Page 13: ...in question The part that caused the damage must be returned to Marvel in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the service...

Page 14: ...y labor 2021 04 23 050H 1 I I I Year Warranty Claims Day Factory use Only Units must be registered prior to warranty submittal Customers may register at www marvelrefrigeration com A proof of purchase...

Page 15: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Page 16: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Page 17: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Page 18: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Page 19: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Page 20: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Page 21: ...21...

Page 22: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Page 23: ...e without notice Such revisions do not entitle the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com 1260...

Reviews: