Extended Non-Use
VACATION/HOLIDAY, PROLONGED
SHUTDOWN
The following steps are recommended for periods of
extended non-use:
1. Remove all consumable content from the unit.
2. Disconnect the power cord from its outlet/socket
and leave it disconnected until the unit is returned to
service.
3. If any ice is visible inside the unit, allow ice to thaw
naturally.
4. Clean and dry the interior of the unit. Ensure all water
has been removed from the unit.
5. The door must remain open to prevent formation of
mold and mildew. Open door a minimum of 2” (50 mm)
to provide the necessary ventilation.
WINTERIZATION
If the unit will be exposed to temperatures of 40oF (5oC) or
less, the steps above must be followed.
For questions regarding winterization, please call
Marvel Refrigeration at 616.754.5601
CARE & CLEANING
Cleaning Condenser
INTERVAL - EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille free
of dust and lint, and clean the condenser when necessary.
Depending on environmental conditions, more or less
frequent cleaning may be necessary.
DO NOT use any type of cleaner on the condenser unit.
1. Remove the grille (See GRILLE INSTALLATION).
2. Clean the condenser coil using a soft brush with a
"combing" action or vacuum cleaner. Do not touch the
condenser coil.
3. Install the grille.
Figure 32
Condenser
!
WARNING
WARNING -
Disconnect electric power to the unit
before cleaning the condenser.
NOTE
Damage caused by freezing temperatures is not covered by
the warranty.
!