TROUBLESHOOTING 

POSSIBLE CAUSE

• Unit interior needs cleaned.
• Unit not level.
• Unit not level.
• Weak floor.
• LED light burned out.
• No power at outlet.
• Control Panel turned “OFF”.
• Line Cord not plugged into power 

source.

• House fuse blown.
• Prolonged door openings.
• Control Panel set too cold.
• Condenser needs cleaning.
• Too many door openings.
• Prolonged door openings.
• Hot, humid weather increases 

condensation.

• Hot, humid weather increases    

condensation. 

• Control improperly set.
• Control improperly set.
• Faulty thermometer.

CORRECTION

• Clean inside of unit. See “Care and Cleaning” pg. 7.
• Adjust leveling legs. See leveling leg instructions.
• Adjust leveling legs. See leveling leg instructions.
• Rebuild floor or move to a different location.
• Replace LED light.
• Test outlet with lamp. 
• Turn unit on with on/off pad on Control Panel.
• Plug unit into power source.

• Reset house fuse. 
• Reduce number and/or duration of door openings.
• Raise temperature of unit via Control Panel.
• Clean condenser. See “Care of Unit” pg 7.
• Reduce number and/or duration of door openings.
• Reduce number and/or duration of door openings.
• As humidity decreases, moisture will disappear.
• Move unit to cooler location.
• As humidity decreases, moisture will disappear.
• Move unit to cooler location.
• Reset to slightly warmer temperature.
• Reset control to desired temperature.
• Recheck with second thermometer.

PROBLEM

Odor in cabinet
Noisy operation
Unit vibrates

Interior light not working

Appliance will not run.

Appliance runs too long.

Moisture collects inside of unit.

Moisture collects on outside
surface of the unit.

Interior too hot/too cold

Diagnostic LED

In the back in the grille there is a diagnostic/status
LED. This led is used to help diagnosis any problems
with the unit and to tell its status.

LED Status

Not on 
Continuously on
1 Blink and pause
2 Blink and pause
3 Blink and pause

Code/Problem

Unit does not have power
Unit is "ON" and operating correctly
For shorted or open thermistor
Disconnected Display Board
Compressor is locked out

8

Summary of Contents for 80RD

Page 1: ...Marvel 80RD Installation Operation Maintenance Instructions...

Page 2: ...ry was assumed by the carrier upon acceptance of the shipment As directed on the side of the packaging carton claims for loss or damage sustained in transit must be made on the carrier as follows Exte...

Page 3: ...to the back of your drawer refrigerator If your installation is a built in undercounter application you do not need to apply this feature If your installation is a free standing application with no c...

Page 4: ...t be used for extended periods of time The LED light will continue to operate when the drawers are opened as long as the unit is connected to a power source At time of initial start up the control pan...

Page 5: ...an abrasive powder solvent polish cleaner or undiluted detergent Door Gasket The vinyl gasket may be cleaned with mild soap and water a baking soda solution or a mild scour ing powder Care of Unit 1 A...

Page 6: ...Lift the drawer up from the slides at 90 to fully extricate the drawer from the cabinet fig 3 2 Remove drawer fronts Do this by removing the 8 phillips screws and washers securing the drawer front to...

Page 7: ...nt lines that were applied prior to removing the door from the drawer Reinstall phillips head screws and washers Snug down but do not tighten fully final adjustment of drawer front will be done after...

Page 8: ...s Raise temperature of unit via Control Panel Clean condenser See Care of Unit pg 7 Reduce number and or duration of door openings Reduce number and or duration of door openings As humidity decreases...

Page 9: ...hased or the manufacturer for the name of the nearest authorized service rep resentative The service representative will have full authority to make any repairs deemed necessary 2 If you are in an are...

Page 10: ...ical codes low or high voltages failure to provide necessary maintenance or other unrea sonable use Parts or Service Not Supplied or Designated by Marvel The above warranties also do not apply if The...

Page 11: ...NOTES 11...

Page 12: ...41009146A W W W M A R V E L I N D U S T R I E S C O M Phone 765 962 2521 Fax 765 962 2493 MARVEL I N D U S T R I E S 233 Industrial Parkway P O Box 997 Richmond IN 47375 0997...

Reviews: