Condenser:

The condenser tubing inside the cabinet

does not require frequent cleaning; however, satis-
factory cooling depends on adequate ventilation over
the coils. Be sure that nothing obstructs the required
air flow openings in front of the cabinet. At least once
or twice a year brush or vacuum lint and dirt from the
condenser for efficient performance by unscrewing
the grille on the bottom front of the cabinet.

Cabinet:

The painted cabinet can be washed with

mild soap and water and thoroughly rinsed with clear
water. Never use abrasive scouring powders.

Interior:

Wash interior compartment with mild soap

and water. Do not use an abrasive powder, solvent,
polish cleaner or undiluted detergent.

Glass Door:

Use a glass cleaner or mild soap and

water and soft cloth to clean the glass door model.
Do not use any abrasive powders.

Door Gasket:

The vinyl gasket may be cleaned with

mild soap and water, a baking soda solution or a mild
scouring powder.

Light Tube Replacement:

WARNING! DISCONNECT

THE POWER CORD BEFORE ATTEMPTING LIGHT
TUBE HOUSING ASSEMBLY

REPLACEMENT.

Failure to do so may result in an electrical shock that
could severely injure you. 

This product uses one, 6 watt light tube to illuminate
the interior of the beverage center. The light tube is a
very reliable electrical component, but should it not
function properly, please call the dealer you pur-
chased your beverage center from for a replacement
light tube housing assembly. Use only an original
equipment light tube housing assembly from your
dealer or manufacturer.

Using a 

5

/

16

” hex-head driver, remove the two hex-

head screws holding the old light tube housing
assembly in place. Disconnect the  electrical plug
from the cabinet’s electrical receptacle and discard
the old light tube housing assembly. Reconnect the
electrical plug of the new light tube housing assem-
bly to the cabinet’s electrical receptacle. Make sure
it is secure and fully inserted.

Using the 

5

/

16

” hex-head driver, resecure the two

hex-head screws back into their original positions to
fasten the light tube housing assembly to the top of
the cabinet.

Re-use the original two screws to secure the light tube
housing in place. Plug the beverage center into the
electrical socket. Check to see if the light tubes oper-
ate properly. Your light tube’s replacement is complete.

The light tubes are not covered by your guarantee. A
replacement light tube housing can be obtained from
your service provider or from Marvel Industries.

What to do in
the Event of a Power Failure

Most power failures are corrected within two hours
and will not affect the unit’s temperature providing you
minimize the number of door openings while the
power is off. A gradual rise in temperature should not
have any adverse effect on your wine if power is out
for a longer period. If it is extremely hot, you may
want to move your wines to the coolest location you
can find until power is restored.

Appliance Features

Adjustable Temperature Control:

Please see “how

to Operate Your Refrigerated Beverage Center” on
page two.

Interior Light and Switch:

The interior light makes it

easy to view the contents of your beverage center.
When the switch is in the
“OFF” position, the light
will come on when the
door is opened. When
the switch is pushed such
that the “red” portion of
the rocker is showing, the
switch is in the “on” position and the interior light will
stay on continuously. 

Remember to turn the off the light

when it is no longer needed.

3

Summary of Contents for 6SBAR

Page 1: ...Marvel 6SBAR Beverage Center Installation Operation Maintenance Instructions Part of AGA Foodservice Group ...

Page 2: ...n inspection report from carrier Include the name of carrier representative and the date the inspection was requested Retain inspection report and receipt for filing of a claim Concealed Damage This must be reported to the carrier within fifteen days Obtain inspection report from the carrier Retain the inspection report for filing the claim DO NOT RETURN DAMAGED MERCHANDISE TO MANUFACTURER FILE TH...

Page 3: ...d section of the fixed position upper wire rack to provide clearance for the bottles and or containers to stand upright To start your appliance use a screwdriver to turn the control clockwise to the middle thermostat setting see figure 2 Once the beverage center is loaded allow at least 48 hours for the unit to stabilize before making any adjustments to the initial setting Insert Wine Bottles The ...

Page 4: ...ing the old light tube housing assembly in place Disconnect the electrical plug from the cabinet s electrical receptacle and discard the old light tube housing assembly Reconnect the electrical plug of the new light tube housing assem bly to the cabinet s electrical receptacle Make sure it is secure and fully inserted Using the 5 16 hex head driver resecure the two hex head screws back into their ...

Page 5: ...lems that you can remedy without difficulty to avoid an unnec essary service call If you do need service contact your dealer or the manu facturer In any correspondence refer to the model number and serial number of your unit which is located on the lower front cabinet flange Retain you proof of purchase You may want to record these numbers in the space provided on this page Follow the procedure ou...

Page 6: ...ere your appliance was purchased or the manufacturer for the name of your nearest authorized service representative The service represen tatives will have full authority tom make any repair deemed necessary If you are in an area where there is no service repre sentative write or call the manufacturer directly We will make recommendations as to the proper proce dure for correction Service work and ...

Page 7: ... not returned for inspection if so requested by MARVEL The refrigeration equipment is not in the posses sion of the original end use purchaser THE WARRANTIES SET FORTH HEREIN ARE THE ONLY WARRANTIES EXTENDED BY MARVEL INDUS TRIES ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE DURATION OF THESE EXPRESS WARRANTIES IN NO EVENT SHALL MARVEL INDUS TRIES BE L...

Page 8: ...41008927 Rev A W W W M A R V E L I N D U S T R I E S C O M Phone 765 962 2521 Fax 765 962 2493 Marvel Industries Part of AGA Foodservice Group 233 Industrial Parkway P O Box 997 Richmond IN 47375 0997 ...

Reviews: