ENGINE AND EMISSION CONTROL SYSTEM
6E1-15
SH410
A-2 MALFUNCTION INDICATOR LAMP CIRCUIT CHECK
(MALFUNCTION INDICATOR LAMP FLASHES AT IGNITION SWITCH ON.)
STEP
ACTION
YES
NO
1
MIL Flashing Pattern Check
1) Turn ignition switch ON.
Does lamp flashing pattern indicate diagnostic trouble
code?
Go to Step 2.
Substitute a known-good
ECM (PCM) and recheck.
2
Diagnosis Switch Circuit Check
Is diagnosis switch terminal connected to ground via
service wire?
System is in good
condition.
“V” circuit shorted to
ground. If circuit is OK,
substitute a known-good
ECM (PCM) and recheck.
A-3 MALFUNCTION INDICATOR LAMP CIRCUIT CHECK
(MALFUNCTION INDICATOR LAMP DOES NOT FLASH OR JUST REMAINS ON EVEN WITH GROUND-
ING DIAGNOSIS SWITCH TERMINAL.)
STEP
ACTION
YES
NO
1
MIL Circuit Check
1) Turn ignition switch OFF and disconnect connec-
tors from ECM (PCM).
Does MIL turn ON at ignition switch ON?
“V/Y” circuit shorted
to ground.
Go to Step 2.
2
ECM (PCM) Connection Check
1) Turn ignition switch OFF.
Is connector (C01-8 connection) connected to ECM
(PCM) properly?
Go to Step 3.
Poor connector connection.
3
Diagnosis Switch Terminal Circuit Check
1) Connect connectors to ECM (PCM).
2) Using service wire, ground C01-8 terminal with
connectors connected to ECM (PCM).
3) Turn ignition switch ON.
Does MIL flash?
“V/W” or “Bl/B” cir-
cuit open.
Substitute a known-good
ECM (PCM) and recheck.
Fig. for STEP 3
1. ECM (PCM) coupler connected
2. Body ground
3. Service wire