RECOVERY, EVACUATION AND CHARGING
OPERATION PROCEDURE FOR CHARGING A/C WITH REFRIGERANT
Recharge 600
"
60 g of
refrigerant in gas form
REFRIGERANT RECOVERY
When discharging refrigerant out of A/C system, always recover it
by using refrigerant recovery and recycling equipment.
Discharging it into atmosphere would cause adverse effect to envi-
ronments.
NOTE:
When handling recovery and recycling equipment, be sure to
follow the instruction manual for the equipment.
EVACUATING AND CHARGING
Refer to AIR CONDITIONING BASIC MANUAL
(99520-02130).
NOTE:
Specified amount of refrigerant: 600
"
60g
A: High pressure service valve
B: Low pressure service valve
1. Manifold gauge set
2. Low pressure gauge
3. High pressure gauge
4. Recovery equipment
AIR CONDITIONING (OPTIONAL)
1B-15