background image

AC Voltage 

(True RMS)

Range

Resolution

Input 

impedance

Accuracy

HFR1

selected 

45 to 60Hz

HFR2 selected

45Hz

to

500Hz

500Hz 

to

1kHz

1kHz 

to

2kHz

600mV

0.01mV

10M

:

2.0% + 20

1.0% + 

20 

1.5% + 

20

N/A

6V

0.0001V

11M

:

60V

0.001V

10M

:

2.0% 

+ 20

600V

0.01V

750V

0.1V

2.0% + 20 

N/A

AC coupled true rms AC voltage accuracy is specified from 2% to 100% of range.

Crest factor: 3 at full scale, 6 at half scale 

High frequency reject filter -3dB points: HFR1 at 1kHz, HFR2 at 100kHz

Peak hold accuracy (45Hz to 500Hz): 60V to 750V AC ± (3.0% rdg + 500 dgts)

Peak hold response time: 1ms

Overload protection: 1000V DC or 750V AC rms

AC + DC Voltage

 (True RMS)

Range

Resolution

Input 

impedance

Accuracy

45Hz

to

500Hz

500 Hz 

to

1 kHz

1 kHz 

to

2 kHz

600mV

0.01mV

10M

:

1.5% + 30 2.0% + 30

N/A

6V

0.0001V

11M

:

60V

0.001V

10M

:

2.5% + 30

600V

0.01V

750V

0.1V

2.5% + 30

N/A

Specification
MM94 TRMS Digital Multimeter

AC coupled true rms AC voltage accuracy is specified from 2% to 100% of 

range.

Crest factor: 3 at full scale, 6 at half scale 

 

Overload protection: 1000V DC or 750V AC rms

Current

Range

Resolution

Voltage

burden

Accuracy

DC

AC 

(true rms)

AC+DC 

(true rms)

45 Hz to 1 kHz

600μA

0.01μA

500mV

0.5% + 10

1.5% + 20 2.0% + 30

6000μA

0.1μA

2V

60mA

0.001mA

500mV

400mA

0.1mA

2V

1.0% + 10

20A 

Note 1

1mA

2.0% +10

2.5% + 20 3.0% + 30

AC coupled true rms AC current accuracy is specified from 2% to 100% of range.

Crest factor: 3 at full scale, 6 at half scale

Peak hold accuracy on AC current ranges (45Hz to 500 Hz):  

    ± (3.5% rdg + 500 dts)

Peak hold response time: 1ms

Input protection: 0.5 A/1000 V fast blow ceramic fuse on 600μA to 400mA ranges 

 

20A/600V fast blow ceramic fuse on 20 A range

Note 1:  Apply currents >10 A for 30 seconds maximum, then allow a 10 minute 

cooling period.

Specification
MM94 TRMS Digital Multimeter

Resistance

Range

Resolution

Open circuit 

voltage

Accuracy

600

:

0.01

:

-3.0V dc

0.3

%

 + 20

6k

:

0.0001k

:

-1.2V dc

60k

:

0.001k

:

600k

:

0.01k

:

6M

:

0.0001M

:

1.0% + 10

60M

:

0.001M

:

3.0

%

 + 20

Overload protection: 600V DC or AC rms

Conductance 

(6000 counts only)

Range

Resolution

Open circuit 

voltage

Accuracy

60nS

0.01nS

-0.7V dc

1.0

%

 + 10

Overload protection: 600V DC or AC rms

Capacitance 

(6000 counts only)

Range

Resolution

Accuracy

6nF

0.001nF

3.0% + 30

60nF

0.01nF

3.0% + 10

600nF

0.1nF

6μF

0.001μF

60μF

0.01μF

600μF

0.1μF

6mF

0.001mF

5.0% + 10

Overload Protection: 600V DC or AC rms

Specification
MM94 TRMS Digital Multimeter

Specification
MM94 TRMS Digital Multimeter

Frequency

Range

Resolution

Trigger 

level

Accuracy

60Hz

0.001Hz

>1.5V

0.1% + 10

600Hz

0.01Hz

6kHz

0.0001kHz

60kHz

0.001kHz

600kHz

0.01kHz

6MHz

0.0001MHz

>2.5V, <5V

10MHz

0.001MHz

Minimum input: >6Hz

Minimum pulse width: >100 ns

Duty cycle limits: >30% and <70%

Overload protection: 600V DC or AC rms.

Duty Cycle

Range

Resolution

Resolution

Pulse 
width

Accuracy 
(5V logic)

5% to 95%

40Hz to 1kHz

0.1%

>10

μ

s

2.0% + 10

10% to 90%

1kHz to 10kHz

20% to 80%

10kHz to 20kHz

Overload protection: 600V DC or AC rms

Summary of Contents for MM94

Page 1: ...Measurements 15 3 24 Continuity Testing 15 3 25 Diode Testing 16 4 Maintenance 16 4 1 Battery Replacement 16 4 2 Fuse Replacement 17 4 3 Test Lead Replacement 17 4 4 Calibration 17 4 5 Cleaning 18 4 6 Repair Service 18 4 7 Storage Conditions 18 5 Warranty 19 Measurement Categories 20 Specifications 1 1 SAFETY INFORMATION Always read before proceeding REMEMBER SAFETY IS NO ACCIDENT These instructio...

Page 2: ...th CAT III and CAT II installations up to 1000V to earth and within the operating temperature and humidity range specified The CAT III 1000V marking does not mean the clamp meter can be used to 1000V AC rms but that it will be safe to the user if inadvertently connected across a voltage up to 1000V AC rms to earth If the removable probe tip caps are not fitted to the probes of the test leads their...

Page 3: ... of LCD Symbols 7 HFR1 High frequency reject 1 kHz selected HFR 2 High frequency reject 100 kHz selected RANGE Manual ranging is selected MAX Maximum indication is displayed MIN Minimum indication is displayed HOLD Display hold is activated P Indicates peak measurement P Indicates peak measurement REL Relative function selected Indicates 30V at input terminals AC Indicates AC measurement DC Indica...

Page 4: ...ions connect the test leads to the circuit being measured and read the measured ac voltage from the display 11 3 15 DC Voltage Measurements Connect the black test lead to the COM terminal and the red test lead to the terminal Set the rotary switch to the or position as required Taking all necessary safety precautions connect the test leads to the circuit being measured and read the measured dc vol...

Page 5: ... if d600 15 3 25 Diode Testing If the diode to be tested is in circuit be sure the circuit power is switched off Connect the black test lead to the COM terminal and the red test lead to the terminal Set the rotary switch to the position Press the SHIFT button twice The LCD will display the symbol Taking all necessary safety precautions connect the test leads to the diode being tested If the diode ...

Page 6: ...ered neglected contaminated or damaged by accident or abnormal conditions of operation handling or storage Martindale authorised resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Martindale Martindale s warranty obligation is limited at Martindale s option to refund of the purchase...

Page 7: ...range Crest factor 3 at full scale 6 at half scale Peak hold accuracy on AC current ranges 45Hz to 500 Hz 3 5 rdg 500 dts Peak hold response time 1ms Input protection 0 5 A 1000 V fast blow ceramic fuse on 600μA to 400mA ranges 20A 600V fast blow ceramic fuse on 20 A range Note 1 Apply currents 10 A for 30 seconds maximum then allow a 10 minute cooling period Specification MM94 TRMS Digital Multim...

Page 8: ...0 R H Altitude up to 2000m Pollution degree 2 indoor use SAFETY Conforms to BS EN 61010 1 BS EN 61010 2 033 CAT IV 600V CAT III 1000V Class II double insulation EMC Conforms to BS EN 61326 1 Specification MM94 TRMS Digital Multimeter SPECIFICATION FOR TL16 TEST LEADS Maximum voltage 1000V AC DC Maximum current 10A continuous Connector 4mm banana plug with fixed shroud Environmental Temperature Ope...

Reviews: