Note:
There must be no more than one master in the chain.
Set all other connected fixtures to operate as slaves.
To set the first fixture to be the master:
1.
Enter the control menu and scroll to
. Press ENTER.
2.
Scroll to
. Press ENTER.
3. Set show mode options as described above.
To set other fixtures as slaves:
1.
Enter the control menu and scroll to
. Press ENTER.
2.
Scroll to
. Press ENTER.
Link the master and slave fixtures in a chain, using DMX cable to
connect each fixture’s DMX OUT socket to the next fixture’s DMX
IN socket as described in the Safety and Installation Guide.
Other settings
LED display on/off (
)
To set the control panel’s LED display to be on all the time, or to
automatically sleep when not in use:
1.
Select
in the control menu and press ENTER.
2.
Select
and press ENTER.
3.
Select
(display on) or
(display off when not in use).
4.
Press ENTER to save your selection.
LED display inversion (
)
To invert the control panel’s LED display for easier reading:
1.
Select
in the control menu and press ENTER.
2.
Select
and press ENTER.
3.
Select
to invert the display.
4.
Press ENTER to save your selection or MENU to escape.
Manual mode (
)
Effects can be set from the control panel. To keep the effect
settings, do not exit the menu.
See the 6-channel mode DMX table for command values. To set
effects from the control panel:
1.
Enter the control menu and scroll to
. Press ENTER.
2.
Scroll to the color or effect to adjust. Press ENTER.
3.
Press
▼ or ▲ to specify a value from 0 to 255 for the effect.
4.
Press ENTER to set the effect.
5.
Press MENU and repeat for the other colors or effects.
Auto test (
)
To test all of the fixture functions select
and press ENTER.
Press MENU to exit the test routine.
Fixture readouts
Hours:
To display the fixture’s total operating hours select
and press ENTER. Press MENU to exit.
Firmware: To display the firmware version number,
select
and press ENTER. Press MENU to exit.
Settings reset
To return all user settings to the factory default values, select
in the control menu. Press ENTER to confirm or MENU to
escape.
Remote control operation
The remote control works with all Compact PAR Mini LED
fixtures within range.
To operate the Compact PAR Mini LED with the remote control:
Verify that the fixture is not connected to a DMX controller.
Press MENU to enter the control menu.
1. Scroll to
and press ENTER.
2. Select
and press ENTER.
3. Select
to disable Show Mode. Press ENTER.
4. To execute commands, point the remote control towards the
front of the fixture and the press corresponding button. See
table below.
Remote Control Commands
Replacing the wireless remote control battery
The wireless remote control uses a single CR 2025
coin/button/cell 3 V lithium battery. To replace the battery:
1. Depress the battery tray lock on the reverse of the remote
control and slide out the battery tray. Remove the old
battery.
2. Insert a fresh battery with the positive terminal towards the
back of the remote. A diagram on the remote control
indicates the correct orientation.
3. Align the battery tray to the remote control and re-insert the
tray ensuring that the locking mechanism is secure.
4. Dispose of used batteries in accordance with local
regulations.
If the coin/button/cell battery compartment does not close
securely, stop using the product and keep it away from children
and animals. Contact Martin Professional for Service and
Support.
Troubleshooting
Symptom
Potential Causes
Remedies
No light from
fixture, control
panel dead
Power supply issue
such as blown fuse,
faulty connector or
damaged cable
Ensure that the mains
supply is connected
and supplying power to
the fixture
Check all power
connections and
cables
Check and if
necessary replace the
fuse
Fixture does not
respond to DMX
control
Fault in the DMX
network due to
connector or cable
damage, incorrect
DMX addressing, or
signal interference
Ensure that fixture’s
DMX address matches
address set on DMX
control device
Check DMX cables
and connections
Ensure that DMX link
is terminated
Reduce number of
fixtures on DMX link
Attempt to control the
fixture with another
DMX control device
Move or shield link if it
is close to unshielded
high-voltage cables
Fixture does not
respond in Show
Mode
Fixture set to run as
slave
Change master/slave
setting master
Sound trigger
disabled
Enable sound trigger
Show Mode disabled
or no show selected
Change DMX state
setting to Show Mode
Select a show
Microphone
sensitivity too low
Increase sensitivity
Fixtures don’t
respond in
master/slave
mode
Fixture receiving
multiple control
signals
Disconnect or turn off
DMX controller
Verify there is only one
fixture master fixture
No master fixture
Set first fixture in chain
as master
Fixture does not
respond to remote
control
Remote control out
of range
Move closer to fixture
Battery exhausted
Replace battery
Incorrect menu
settings
Verify show mode is
disabled (
- =
)
Button Function
BL
Toggle LEDs on/off
SP
Adjust speed (4 levels). Use with JU, FA, and SU.
Dimming (4 levels)
FL
Strobe (4 speeds)
R
Adjust Red intensity (off, 4 levels)
G
Adjust Green intensity (off, 4 levels)
B
Adjust Blue intensity (off, 4 levels)
W
no function
A
no function
UV
no function
JU
Jump Mode
– snaps thru pre-programmed colors. Adjust
speed with SP.
FA
Fade Mode
– fades thru pre-programmed colors. Adjust
speed with SP.
AU
Auto-trigger mode.
SU
Music-triggered Sound Mode. Adjust sensitivity level with
SP.
CM+
Next color
CM-
Previous color
Information subject to change without notice. HARMAN
Professional Denmark ApS disclaims liability for any injury,
damage, direct or indirect loss, consequential or economic loss
or any other loss occasioned by the use of, inability to use or
reliance on the information contained in this document.
©2017
HARMAN
Professional
Denmark
ApS
.
All
rights
reserved. Martin
®
is a registered trademark of HARMAN
Professional Denmark ApS registered in the United States and/or
other countries. Features, specific-ations, and appearance are
subject to change without notice.
HARMAN Professional Denmark ApS
Olof
Palmes Allé 18 • 8200 Aarhus N • Denmark
www.martin.com
Document revision:
A
IN
OUT
IN
OUT
IN
OUT
IN
OUT