6
T-Rex user manual
AC
POWER
2
The T-Rex’s operating voltage is printed on the serial number label near the AC
input. Verify that the operating voltage closely matches the AC supply voltage
before applying power. Contact your Martin dealer if the voltage on the label
differs from the AC mains voltage by more than five percent.
I N S T A L L I N G A P L U G O N T H E M A I N S
L E A D
The fixture’s mains lead may require a grounding-type cord cap that fits your
power distribution cable or outlet. Consult a qualified electrician if you have any
doubts about proper installation.
Warning!
For protection from dangerous electric shock, the fixture must
be grounded (earthed). The AC mains supply shall have
overload and ground-fault protection.
Important! Verify that the feed cables are undamaged and rated for the
current requirements of all connected devices before use.
Following the cord cap manufacturer’s instructions, connect the yellow and green
wire to ground (earth), the brown wire to live, and the blue wire to neutral. The
table below shows some pin identification schemes.
Wire
Pin
Marking
Screw color
brown
live
“L”
yellow or brass
blue
neutral
“N”
silver
yellow/green
ground green