background image

 

 

 

RUSH SM 850 

 

 

 

 

User Manual

 

 

 

Summary of Contents for RUSH SM 850

Page 1: ...RUSH SM 850 User Manual ...

Page 2: ...or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Martin RUSH JEM and other trademarks mentioned herein are registered as the property of Harman International Industries Martin Professional Olof Palmes Allé 18 8200 Aarhus N Denmark www martin com Manual Revision C ...

Page 3: ...ne on a truss 10 Securing with a safety cable 11 AC power 11 Remote control 12 Wired remote control 12 4 channel wireless remote control and receiver 12 Operation 13 Filling the tank 13 Making fog 13 Maintenance 14 Cleaning 14 Replacing the primary fuse 14 Replacing the wireless remote control battery 15 Service and repairs 15 Troubleshooting 16 Technical Specifications 17 ...

Page 4: ...not for household use It presents risks of severe injury or death due to fire and burn hazards electric shock falls and respiratory problems The fog produced by the machine is hot enough to cause burns or eye injury if the safety precautions below are not followed Install operate and service Martin products only as directed in their user manuals or you may create a safety hazard or cause damage th...

Page 5: ...on Socket outlets or external power switches used to supply the fog machine with power must be located near the fog machine and easily accessible so that the fog machine can easily be disconnected from power Replace defective fuses with ones of the specified type and rating only Disconnect the fog machine from power immediately if the power plug or any seal cover cable or other component is damage...

Page 6: ...combustible materials at least 1 m 40 in away from the machine Do not attempt to bypass thermostatic switches or fuses Replace fuses only with ones of the type and rating specified in this manual for the machine Protection from injury Ensure that any supporting structure and or hardware used can hold at least 10 times the weight of all the devices they support If suspending from a rigging structur...

Page 7: ...Block access below the work area and work from a stable platform whenever installing servicing filling or moving the fog machine In the event of an operating problem stop using the fog machine immediately and disconnect it from power Do not attempt to use a fog machine that is obviously damaged Do not modify the fog machine in any way Refer any service operation not described in this manual to a q...

Page 8: ...er manual a wired remote control a wireless remote control transmitter and receiver a 1 5 m 5 ft power cable local power plug not included on some models and an adjustable mounting bracket Before using the product 1 Read Safety information on page 4 before installing operating or servicing the fog machine 2 Unpack and ensure that there is no transportation damage before using the fog machine Do no...

Page 9: ...9 Fog machine overview 1 mounting bracket 6 power switch 2 clamp attachment point 7 remote control socket 3 fluid tank 8 remote control socket 4 secondary attachment point 9 AC power socket 5 fog output nozzle 10 No fluid light ...

Page 10: ...d to a truss or similar rigging structure and tilted up to 45 degrees from horizontal When installing the fog machine with the mounting bracket hanging vertically down you can use an open type clamp such as a G clamp If installing with the mounting bracket in any other orientation you must use a half coupler clamp see illustration on right that completely encircles the truss chord To clamp the fog...

Page 11: ...wer switches used to supply the fog machine with power must be located near the fog machine and easily accessible so that the fog machine can easily be disconnected from power The fog machine can be hard wired to a building electrical installation if you want to install it permanently or a power plug not supplied that is suitable for the local power outlets can be installed on the power cable If y...

Page 12: ...annel wireless remote control and receiver The 4 channel wireless remote control transmitter shown below to left has a range of 30 meters 100 feet It provides individual control of up to 4 fog machines and simultaneous control of an unlimited number of machines in up to 4 groups The remote control receiver shown above to right connects to a remote control socket on the rear panel It has green read...

Page 13: ...not come above the filler opening 4 Place the fluid tank back into the machine 5 Replace the filler cap and verify that the feed hose touches the bottom of the tank 6 Wipe up any spills or drips Making fog 1 Fill the fluid tank as described above 2 Connect a remote control or wireless remote control receiver as described on the previous page 3 Connect the fog machine to AC power and switch it on A...

Page 14: ...leaning or maintenance is not covered by the product warranty Inspect fog machines within their first 100 hours of operation to see whether cleaning is necessary Check again at frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your Martin dealer about a suitable maintenance schedule Use gentle pressure only when cleani...

Page 15: ... a fresh battery with the negative terminal towards the spring 4 Align the covers and replace the screw to close Service and repairs Do not try to repair the fog machine by yourself as this may result in damage malfunction and it may potentially void your product warranty The equipment must only be serviced or repaired by an authorized Martin service technician Installation on site service and mai...

Page 16: ...luid drips or spits from nozzle or loud noise when firing machine Incompatible fog fluid Discard fluid and replace with fluid that is approved by Martin for this machine No fog output Machine not ready Allow machine several minutes to heat up Fluid level low Add fluid see page 13 Selected remote control button does not match receiver DIP switch setting Change DIP switch setting see page 12 or pres...

Page 17: ... Length 411 mm 16 2 in Width 294 mm 11 6 in Height with hanging bracket 309 mm 12 2 in Weight dry 7 3 kg 16 1 lbs Weight filled 8 9 kg 19 7 lbs Performance Coverage volume 200 m3 7062 ft3 minute Maximum operating time at full output 45 seconds Ready time 8 minutes ...

Page 18: ...ting Standing or hanging Orientation Up to 45 from horizontal Clearance around machine 500 mm 20 in Connections AC Power IEC Male inlet C14 Remote control wired DIN 41524 5 pin 45 180 inlet Remote control wireless receiver DIN 41524 5 pin 45 180 inlet Electrical EU model AC power 220 240 V nominal 50 60 Hz Main fuse 5 AT slow blow 250 V Typical power and current 240 V 50 Hz 950 W 3 8 A US model AC...

Page 19: ...t cable US 10 A IEC C13 female molded NEMA 5 15P 1 5 m 4 9 ft Wired remote control with 4 5 m 15 ft cable P N 50480855 Wireless transmitter 4 channel P N 50480853 Wireless receiver P N 50480854 Accessories Approved Fluids RUSH Fog Fluid JEM Pro Clean Supreme Various sizes available contact your dealer or see www martin com for details Installation Accessories Half coupler clamp P N 91602005 G clam...

Page 20: ...ducts are supplied in compliance with Directive 2012 19 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products ...

Page 21: ......

Page 22: ......

Reviews: