8
PAL 1200, PAL 1200 E, PAL 1200 FX User Manual
s e c t i o n 3
C O N N E C T I N G T H E C O N T R O L L E R
All effects in the PAL are fully DMX-512 and Martin RS-485 implemented. Control data is transmitted from the controller’s
output, via XLR data link cables, to the data input on the PAL. The data output on the PAL allows the serial data link to be con-
tinued to additional lights, and this way up to 32 fixtures can be connected on the same data link.
C o n n e c t i n g t h e s e r i a l l i n k
U S I N G T H E PA L
A N D O T H E R M A R T I N L I G H T S O N LY
1. Connect the data output of your lighting controller to the data input on the PAL.
Data output
via 3 pin
XLR female.
Data input
via 3 pin
XLR male.
5 pin XLR male:
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX Controller
with standard 5 pin XLR output.
3 pin XLR female:
Pin 1: GND (screen)
Pin 2: Signal (+)
Pin 3: Signal (-)
Martin Controller
with standard 3 pin XLR output.
3 pin XLR female:
Pin 1: GND (screen)
Pin 2: Signal (+)
Pin 3: Signal (-)
3 pin XLR male:
Pin 1: GND (screen)
Pin 2: Signal (+)
Pin 3: Signal (-)