background image

26

53D9042. Rev 1 03/03

F

IREPLACE

 M

AINTENANCE

At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should
be removed and the hearth area should be swept as clean as is practical.  The slow absorption of moisture into
the ashes over a long period of time could cause a condition which would be corrosive to the metal fireplace
parts.

At the beginning of each heating season, always operate the flue damper and make sure it has not become
stuck from soot, creosote, etc., during the period of inactivity.

Keep the lower and upper grille panels clean and free from dirt and lint accumulation at all times to get the
maximum efficiency from your fireplace.

As you use the fireplace, expansion and contraction will cause minor cracking of the hearth, back, and side
refractory materials.  This is normal and unavoidable.  If the cracks become large enough or parts dislodge and
metal behind the refractory is exposed, the refractory panels should be replaced with new panels that can be
obtained from your fireplace dealer.

G

LASS

 D

OOR

 M

AINTENANCE

For glass door maintenance, see instructions provided with the glass doors.

C

HECKLIST

 

OF

 DO’S 

AND

 DONT’S

DO’S
1. Do check with local building officials to be sure the installation of the fireplace complies with all building

codes and requirements and obtain required building permits. Do plan your installation with safety as you
primary consideration.

3. Do use only the prescribed material and parts for the installation of the fireplace.
4. Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace.
5. Do trim the face of the fireplace only with noncombustible materials.
6. Do attach the noncombustible face trim material firmly to the face of the fireplace.
7. Do block in or fasten the fireplace to prevent the possibility of the fireplace shifting out of position.
8. Do enclose the chimney where it passes through living spaces or spaces accessible for storage purposes to

prevent contact with and possible damage to the chimney.

9. Do install firestop spacers at each ceiling level when the chimney is installed in a multistory building.
10. Do install the proper chimney cap or chimney housing on the chimney to prevent rain and debris from

entering the chimney.

11. Do keep all flammable liquids, gases and pressurized containers away form the fireplace.
12. Do check the fireplace for proper adjustment and operation before leaving it unattended for long periods of

time.

13. Do inspect and clean the fireplace chimney regularly.
14. Do keep the fire screens closed when the fireplace is left unattended to minimize the danger of sparks

popping out of the fireplace.

15. Do use the grate furnished with and for this fireplace.
16. Do start a fire only with paper, kindling or solid composition fire starters specifically designed for starting a

fire.  The use of liquid fire starter can cause an explosion within the fireplace.

17. Do place all ashes in a metal container with a tight fitting lid and place them on a noncombustible surface

well away from other combustible materials until they have completely cooled.

M

AINTENANCE

 

AND

 S

AFETY

Summary of Contents for MPL PENINSULA

Page 1: ...ON OPERATION AND MAINTENANCE MANUAL THIS FIREPLACE IS LISTED BY OMNI TEST LABORATORIES FOR USE WITH L SERIES CHIMNEY SYSTEM COMPONENTS 53D9042 Rev 1 03 03 GLASS DOORS ARE REQUIRED ON THIS MODEL FIREPL...

Page 2: ...er factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very important that the persons installing and or superv...

Page 3: ...as INTENDED PRODUCT USAGE The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual On...

Page 4: ...ped with doors should be operated only with the doors fully open or doors fully closed If doors are left partly open gas and flame may be drawn out of the fireplace opening creating risks of both fire...

Page 5: ...6 4 CLEARANCES 53D9042 Rev 1 03 03...

Page 6: ...nterfere with chimney performance and cause the fireplace to spill smoke into the room Since the pitch of the roof influences the opening size required at the roof level table 1 should be used as a gu...

Page 7: ...CLEARANCES 6 53D9042 Rev 1 03 03...

Page 8: ...ng chimney cap For use with flat chase top terminations 612 0 6 12 pitch flashing for contemporary installation 1212 6 12 12 12 pitch flashing for contemporary installation LF FS 2 17 inch firestop sp...

Page 9: ...f the fireplace To help prevent the crack from developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the fireplace and imbedded in the m...

Page 10: ...operly install the chimney This is an important part of the installation and the sections of this manual pertaining to chimney installation should be reviewed very thoroughly For your safety some of t...

Page 11: ...CHIMNEY INSTALLATION 10 53D9042 Rev 1 03 03...

Page 12: ...11 53D9042 Rev 1 03 03 CHIMNEY INSTALLATION...

Page 13: ...tly to a building frame member or ceiling joist as shown by Figure 13 You must use at least two 8 penney nails per strap ELBOW INSTALLATION The following are important points that should be observed w...

Page 14: ...13 53D9042 Rev 1 03 03 CHIMNEY INSTALLATION...

Page 15: ...CHIMNEY INSTALLATION 14 53D9042 Rev 1 03 03...

Page 16: ...NTERMEDIATE SECTIONS 4 0 0 1 0 1 1 0 1 1 0 2 1 0 2 1 0 2 1 3 2 1 3 2 1 3 2 4 3 2 4 3 2 4 3 5 4 3 5 4 3 5 4 6 5 4 6 5 4 6 5 7 6 5 7 6 5 7 6 8 3 1 0 0 1 0 0 2 0 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 1 3...

Page 17: ...under the shingles 3 Set the flashing on the roof Hold a section of the outside pipe 13 diameter on the flashing and scribe a line around the flashing then cut the top off the flashing by cutting 1 4...

Page 18: ...should be soldered together to form two watertight seams 3 Place the outer telescope inside the hole in the chase cover and lower it down into the mating pipe of the chimney until the support bracket...

Page 19: ...r will not be connected 2 Place the insulation ring between the AK 4 starting collar and fireplace wall and place the starting collar 4 inch into the hole on the side of the fireplace Fasten it in pla...

Page 20: ...ENDATIONS NOTE The use of outside air for combustion is optional unless required by building codes It is only necessary to supply outside combustion air to one side of the fireplace Use the model AK4...

Page 21: ...n Unions must be of the ground joint type 4 Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces Check with local code authorities before proceeding with the...

Page 22: ...hing the base to the supporting floor will further reduce the possibility of such a crack developing Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the...

Page 23: ...MPL NO PART NAME QTY PART NO 1 Panel Front Ptd Assy 4 042988 2 Panel End Ptd Assy 1 042990 3 Panel End Vented Ptd Assy 1 043006 4 Post Corner Ptd Assy 4 043008 5 Cap Corner Post 2 043009 6 Flange Nail...

Page 24: ...tle combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will not burn well when freshl...

Page 25: ...e is equipped with glass doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONSALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably fou...

Page 26: ...to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cle...

Page 27: ...s for the installation of the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with nonco...

Page 28: ...lace flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all responsible persons in the proper and safe operation of the fireplace 17 Don t fail to instru...

Page 29: ...onents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout...

Page 30: ...Contact the nearest dealer If you cannot locate your dealer call or write Martin Hearth Heating as indicated below 2 If you do not receive satisfactory service from the dealer within a reasonable time...

Page 31: ...30 53D9042 Rev 1 03 03 NOTES...

Page 32: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE CONSUMER 53D9042 REV 1 03 03...

Reviews: