Installation and Setting Up 

 

 

Before connecting the machine to power, verify that the AC supply is adequately 
dimensioned for the current draw of the machine.  
 

 

1200W 220-240V EU / 1050W 100-130V US 

 

1550W 220-240V EU / 1450W 100-130V US 

 

2100W 220-240V EU / 1800W 100-130V US 

 
Check that the local AC voltage is appropriate, as indicated on the machine’s 
serial number label. If your AC voltage is outside the appropriate range, do not 

use the machine. Contact Martin™ Service for assistance. 
 

Se tt ing  up 

Fill the fluid tank with an approved Martin™ fog fluid as shown on page 21. If 
DMX control is being used, connect the machine to the DMX line (see page 19). 
 
If you are using several machines from one control panel in master-slave link 
mode, link the machines in a daisy-chain using the DMX input and output 
sockets. It does not matter which socket is used as input or output. 
 

Final c hec ks  

Before applying power to the machine, verify the following: 

 

the machine is safely located or installed and meets the location 
requirements stated on page 13 

 

the operator is familiar with, and able to comply with, the requirements 

for safe operation listed on page 5. 

 

the fluid is one of the Approved Martin™ fluids listed under “Approved 
fluid types” on page 21. 

 

the machine is electrically grounded (earthed) 

 

the AC power distribution circuits and lines are adequately rated for the 

current load 

 

Turning  on t he  powe r  

Set the mains switch on the rear of the unit, to the ‘ON’ (I) position. The display 
will show 

HEAT

. If the display shows 

OFF

, press the 

FOG

 button on the control 

panel or set the 

RUN MODE

 to 

CONTINUOUS

. After about 6-8 minutes if no 

DMX is connected the display should show 

FOG LEVEL 

(along with the set 

output level) and the machine will begin producing fog. If DMX is connected the 
display will show 

DMX

 when the machine is ready. 

 
The machine will remember its state from when it was turned off last time, so it 
will only power up in OFF mode if you have previously disabled the heaters. 

 

 

To obtain maximum output, wait another few minutes after the READY 
indication is shown, as the machine continues to heat to full operating 
temperature and fog output is reduced while the unit is heating up. 

 

 

Summary of Contents for JEM ZR series

Page 1: ...user manual P N 35010042 D READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...2 Dimensions Legal Dimensions Legal All dimensions are in millimeters...

Page 3: ...loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Martin Harman and all other trademarks in this document pertaining to services...

Page 4: ...t density 15 Setting the Timer 16 Using the Settings menu 16 Setting the DMX base address 16 Display back light setting 16 Setting the master slave link mode 16 Priming the machine after fluid out 17...

Page 5: ...al and the machine is malfunctioning please contact Martin Service Preventing electric shocks Always ground earth the machine electrically Use only a source of AC power that complies with local buildi...

Page 6: ...or pyrotechnic effects Do not attempt to bypass thermostatic switches fluid sensors or fuses Replace fuses only with ones of the type and rating specified in this manual for the machine Provide a mini...

Page 7: ...is swallowed give water and obtain medical advice This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and kn...

Page 8: ...r remote setup and status monitoring This manual contains instructions for all machines in the range but some features are different These symbols show information which is specific to a particular ma...

Page 9: ...ch Mains power connector Fluid pipe connection Fluid container Integrated digital remote control Mains fuse Product details ZR25 Fog output nozzle WARNING High temperature vapor and surfaces If suspen...

Page 10: ...Mains power switch Mains power connector Fluid pipe connection Fluid container Integrated digital remote control Mains fuse ZR35 Fog output nozzle WARNING High temperature vapor and surfaces If suspe...

Page 11: ...wer switch Mains power connector Fluid pipe connection Fluid container Integrated digital remote control Mains fuse ZR45 Fog output nozzle WARNING High temperature vapor and surfaces If suspending ove...

Page 12: ...s switch on the rear of the unit to the ON I position The display will show HEAT If the display shows OFF press the FOG button on the control panel or set the RUN MODE to CONTINUOUS After about 6 8 mi...

Page 13: ...pping bolts fitted to the hanging bracket in place of the normal hand wheel bolts Before first use remove the shipping bolts and replace them with the hand wheel bolts outside of bracket and spacers i...

Page 14: ...s the location requirements stated on page 13 the operator is familiar with and able to comply with the requirements for safe operation listed on page 5 the fluid is one of the Approved Martin fluids...

Page 15: ...used to shut down the heater Settings are Off shutdown heaters off Standby heaters remain on Timer mode or Continuous mode Use the Menu Previous Next buttons to select the RUN MODE option Use the Up...

Page 16: ...revious Next buttons to select the DMX option from the SETTINGS menu Use the Up Down buttons to set the DMX base address from 001 to 511 If you hold down the button the address will count up or down m...

Page 17: ...reset the FLUID OUT error replace refill the fluid tank and use the prime function Use the Previous Next buttons to select the PRIME option from the SETTINGS menu Use the Up Down buttons to change the...

Page 18: ...ontrol Settings The factory settings are option setting FOG LEVEL 50 TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY DMX 001 BACK LIGHT NORM LINK MODE RECEIVE PRIME NO TEMPERATURE NORM ZR45...

Page 19: ...revert to this state If the machine was set to TIMER it will revert to this state If the machine was set to CONTINUOUS it will revert to this state Connection The JEM ZR series machine provides 5 pin...

Page 20: ...f and fog flow rate 0 100 or can trigger a preset flow rate This interface uses closed contact signaling or can respond with 0 10V reference Up to 5 machines can be daisy chained and controlled in thi...

Page 21: ...d for scenic obscuring dramatic strobe effects and white outs RUSH Fog Fluid RUSH Fog Fluid is a specially formulated water based fog formula and is recommended for use with applicable Martin fog effe...

Page 22: ...ct the required temperature and press Enter to store The selected temperature setting will remain after power off and is indicated on the display whilst in standby TEMP NORM and also shows during manu...

Page 23: ...ean Supreme every 200 hours or once a month depending on usage will prolong the life of the heat exchanger in Martin fog and haze machines Connect Pro Clean Supreme fluid to the fogger or hazer then a...

Page 24: ...acuum or compressed air Clean fog fluid residues from the fog output of the machine using a damp cloth Clean the outer casing with a damp cloth only Fuse replacement The main fuse for the machine is l...

Page 25: ...ion in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECEIVE Fog output is weak Machine requires priming Use PRIME option to prime the machine page 17 Wet greasy...

Page 26: ...DMX control FLUID OUT Run out of fluid Refill the fluid tank and operate the prime function in the SETTINGS menu CALIBRATION ERROR The machine has detected an error with its calibration settings and...

Page 27: ...t dry 17 7 kg 39 1 lb Weight filled 22 7 kg 50 0 lb Performance ZR25 Coverage volume 600 m 21 189 ft per minute Fluid consumption max 40 ml per 30 seconds Continuous effect output Ready time 7 minutes...

Page 28: ...d sensing Remote control Integrated digital remote with 3 m cable 3 pin XLR Installation Mounting Standing or hanging Clearance around machine 100 mm 4 in Orientation Up to 40 from horizontal Connecti...

Page 29: ...5P 3 m 9 8 ft P N 11501044 ZR35 US power input cable 15A PowerCON TRUE1 molded NEMA 5 15P 3 m 9 8 ft P N 11501045 ZR45 US power input cable 20A PowerCON TRUE1 molded NEMA 5 20P 2 m 6 6 ft P N 11501046...

Page 30: ...ZR25 US P N 92215330 JEM ZR25 EU P N 92215320 JEM ZR35 US P N 92215350 JEM ZR35 EU P N 92215340 JEM ZR45 US P N 92215370 JEM ZR45 EU P N 92215360 Specifications subject to change without notice For th...

Page 31: ...and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product...

Page 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Reviews: