Installation

15

 

Cable entry

Two types of seal can be 
used for cable entry: 
Thorsman rubber 
membrane cable glands 
(see Figure 9) installed in 
the base module and 
metal cable glands (see 
Figure 10) packed loose 
with the product. If the 
metal glands are used, 
blanking plugs must be 
removed and replaced 
with metal glands.

Use the larger glands for 
power cable entry and the 
smaller glands for DMX 
data cable entry.

Cable glands may need to 
be replaced in the 
following situations:

• If power or data cable is 

used that is not within the diameters specified under “

Included items

” on 

page 8, new cable glands that match cable diameter must be obtained 
from Martin or an electrical supplier.

• Rubber and metal glands must be replaced with new items if cable in an 

existing installation is replaced with cable of a different diameter.

• Used rubber membrane glands must be replaced with new unpierced 

items or replaced with blanking plugs if they are no longer used for cable 
entry.

• If metal cable glands are installed, they must be replaced with blanking 

plugs if no longer used for cable entry.

Replacement rubber membrane glands must have the following 
characteristics:

Temperature range . . . . . . . . . . . . . . . . . . . .   -20° to +70°C or better
Ingress protection rating . . . . . . . . . . . . . . . . . . . . . . . .   IP67 or IP68
Installation plate thickness . . . . . . . . . . . . 0.5-4.0 mm (0.02-0.17 in.)
Power cable gland installation hole diameter . . . . . . 23 mm (0.91 in.)
Data cable gland installation hole diameter  . . . . . . . 16 mm (0.63 in.)

Figure 8: Cable gland options

www.carlosmendoza.com.mx

Summary of Contents for Cyclo Directional IP65

Page 1: ...user manual Cyclo Directional IP65...

Page 2: ...out permission in writing from Martin Professional A S Denmark Information subject to change without notice Martin Professional A S and all affiliated companies disclaim liability for any injury damag...

Page 3: ...manual to a qualified technician If you have any questions about how to operate this luminaire safely contact your Martin Architectural supplier or call the Martin 24 hour service hotline on 45 70 200...

Page 4: ...Ta exceeds 40 C 104 F Keep flammable materials well away from the luminaire Allow the luminaire to cool for 15 minutes before servicing Do not attempt to bypass thermostatic switches or fuses Replace...

Page 5: ...scent tube lifetimes and performance 27 Avoiding condensation and humidity 27 Operation in extreme ambient temperatures 28 Stand alone operation 29 Stand alone operation settings 30 Single stand alone...

Page 6: ...6 Cyclo IP65 Directional user manual A B D C Product overview A Tube module B Base module C Front cover D Metal cable glands if used w w w c a r l o s m e n d o z a c o m m x...

Page 7: ...the white tube s output can be controlled using the colored tubes Luminaires are dustproof and protected from water projections and low pressure water jets to IP65 A self purging humidity valve elimin...

Page 8: ...rself with the procedures involved before starting to install luminaires If you are not familiar with DMX pay particular attention to the section on setting DMX addresses Included items Cyclo IP65 Dir...

Page 9: ...en lift the hinged front cover B If you need to lever the release flap up use a plastic or wooden object as a metal object may damage the glass Avoid damaging seals while you are working 4 To close th...

Page 10: ...B Avoid damaging the seal on the inside of the cover 3 To close the connections compartment first close the hinged cover B then close the release flap A so that it clips down over the cover The seals...

Page 11: ...ounting fasteners 3 Fasten the mounting bracket to the surface with at least two fasteners that have sufficient corrosion resistance and strength to mount the luminaire safely Choice of mounting hardw...

Page 12: ...rms must both be fixed at the same angle Do not twist the luminaire in the support arms or you may deform the product and make it impossible to obtain a waterproof seal The Cyclo IP65 Directional can...

Page 13: ...he weight of the tube module Loosen the arm adjustment screws at both ends of the base module with a long Allen key tilt the arms to the desired angle and retighten slowly rocking the tube module up a...

Page 14: ...om power 1 Open the front cover as described in Access to tube module on page 9 2 See Figure 7 Loosen both the tilt adjustment screws with a long Allen key rotate the tube module to the desired angle...

Page 15: ...ed from Martin or an electrical supplier Rubber and metal glands must be replaced with new items if cable in an existing installation is replaced with cable of a different diameter Used rubber membran...

Page 16: ...h a blanking plug or new gland To install cable using a rubber gland 1 Push a round spiked object through the center of the membrane from the outside of the housing just enough to pierce it Do not enl...

Page 17: ...al or housing 4 Thread the cable through the compression nut E washer D gland C and cable entry B into the housing 5 Allow approx 20 cm 8 in of cable slack inside the housing Prevent the cable entry f...

Page 18: ...nductors in branch circuit distribution boxes To avoid unintentional tripping of the RCD residual current device or ground fault earth leakage circuit breaker ensure that each luminaire s neutral cond...

Page 19: ...in Access to connections compartment on page 10 3 Pass the power input cable through a cable gland as described in Cable entry on page 15 so that approximately 20 cm 8 in of cable is free inside the...

Page 20: ...luminaires with power from a 3 phase system the live conductor in the power input cable that you connect to terminal L1 will be one of the phases Connect one of the remaining phases to terminal L2 an...

Page 21: ...artin Architectural supplier can advise and supply suitable cable Luminaires on a serial data link must be daisy chained in one single line maximum 500 meters 1640 ft long with maximum 32 luminaires T...

Page 22: ...d on the luminaire 4 Continue connecting up to 32 luminaires using the above procedure 5 Terminate the data link by connecting a 120 Ohm 0 25 W resistor across the hot and cold terminals of the last l...

Page 23: ...minaire and selected on the DMX controller before the controller can send commands to the luminaire via a data link For example a Cyclo 04 IP65 Directional with its DMX address set to 101 uses channel...

Page 24: ...index asp see illustration below 3 You can also look up DIP switch settings using the Martin DIP Switch Calculator available for use and downloadable at http www martin dk service dipswitchpopup htm I...

Page 25: ...299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174...

Page 26: ...d alone operation settings on page 30 for details of how to set these pins After making connections After you have finished making power and data connections make sure that any holes not used for cabl...

Page 27: ...at http www martin com service Achieve optimum tube performance by burning in new fluorescent tubes i e running them for 100 hours at full power Avoiding condensation and humidity Excess humidity insi...

Page 28: ...tubes to avoid damage to components If this happens luminaires must be reset by powering them off and on again before tubes can be restarted Flickering can be avoided at ambient temperatures below fre...

Page 29: ...tall this link Synchronized action in all luminaires is triggered by one master luminaire In both single and master slave stand alone operation luminaires are programmed by setting the pins on the DIP...

Page 30: ...between colors If DIP switch pin 7 is set to OFF blackout fading colors fade to almost blackout before the next color fades in If DIP switch pin 7 is set to ON crossfading color fading overlaps If tw...

Page 31: ...the data link each time it starts a new action Slave luminaires start their next programmed action when they receive this signal from the master luminaire Programs can be identical on all luminaires...

Page 32: ...ene is determined by the speed setting of the DIP switch A slave will not respond to new synchronization signals until its scene is complete When crossfading is selected each color takes up one scene...

Page 33: ...ivated Example 2 DIP switch 7 is set to OFF blackout fading and only red is activated Example 3 DIP switch 7 is set to ON crossfading and red and blue are activated Tube turned fully off Fade in Fade...

Page 34: ...minaire to use as master and set this luminaire s DIP switch pin 9 to OFF Note that any luminaire can be set as master but you will obtain the most reliable data signal by either setting the first lum...

Page 35: ...ctional s advanced fluorescent tubes can be dimmed from maximum output right down to zero using one channel per tube on a DMX controller This allows a wide range of color shades with variable intensit...

Page 36: ...er and a mild detergent cleaner such as auto shampoo to clean luminaires Do not use abrasive acidic or caustic cleaning products or you will damage the luminaires anodized finish Do not use a high pre...

Page 37: ...both ends as it is released 5 See Figure 14 To release the diffuser push the locking bars from position B in towards the center of the luminaire until they are in position A Lift the diffuser out of t...

Page 38: ...applying power Tube positions The burning positions of fluorescent tubes affect their warm up times operating temperature light output and tube life For optimum results Install tubes so that the manuf...

Page 39: ...type or rating To replace the fuse 1 Isolate the luminaire from power and ensure that power cannot be reapplied accidentally 2 Open the connections compartment cover as described in Access to connect...

Page 40: ...Martin Architectural supplier for service Voltage setting See Figure 16 The voltage switch on the PCB is factory set to match 100 120 or 200 240 V nominal AC power at 50 or 60 Hz Important Do not chan...

Page 41: ...across data link hot and cold in parallel with last luminaire on link Two devices transmitting on link Check that all luminaires are set as slaves DIP switch pin 9 ON Defective luminaire Bypass lumin...

Page 42: ...ty 1 100 Intensity 100 4 0 2 3 252 253 255 0 1 99 100 Blue intensity Tube off Intensity 1 100 Intensity 100 Table 5 DMX protocol Cyclo 04 IP65 Directional Channel Value Percent Function 1 0 2 3 252 25...

Page 43: ...ter slave Number of DMX channels 3 03 models 4 04 models DMX address setting DIP switch Stand alone and master slave programming DIP switch Protocol USITT DMX512 1990 Receiver RS 485 Construction Hous...

Page 44: ...120 V model 100 V 60 Hz 219 W 2 2 A 120 V 60 Hz 236 W 2 0 A Cyclo IP65 04 Directional 230 V model 208 V 60 Hz 235 W 1 2 A 230 V 50 Hz 234 W 1 1 A 240 V 50 Hz 231 W 1 0 A Measurements made at nominal v...

Page 45: ...K warm white tube 04 model P N 97020009 Osram T5 FQ 54 W 865 HO 6500 K daylight white tube 04 model P N 97020011 Spare parts Osram T5 FQ 54 W 60 HO red tube P N 97020006 Osram T5 FQ 54 W 66 HO green...

Page 46: ...ncil of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at...

Page 47: ......

Page 48: ...ate stand alone 1 2 3 4 5 6 7 8 910 ON 1 Tube 1 2 Tube 2 3 Tube 3 4 Tube 4 04 models 5 6 Program speed 9 ON Stand alone slave OFF Stand alone master single 10 ON Stand alone OFF DMX 7 ON Crossfading O...

Reviews: