Installation
9
The FiberSource CMY150 is equipped with a 1.8-meter (5.9 ft.) length of 3-
conductor 0.75 mm
2
(~18 AWG) electrical cable for connection to the AC power
supply. The cable attaches with 1/4” female spade plugs on the live and neutral
wires and a ring terminal on the ground wire. Other cable can be installed as
follows.
R e p l a c i n g t h e m a i n s l e a d
1 Isolate the fixture from AC power.
2 Remove the fixture housing.
3 Disconnect the existing mains cable and pull it through the hole in the chassis.
4 Pass the new cable through the hole in the chassis and connect the leads. The live
wire connects to PL3, the neutral wire connects to PL1, and the ground wire connects
to the chassis screw terminal.
5 Draw up the slack in the AC and data cables and replace the fixture housing.
I n s t a l l i n g a c o r d c a p o n t h e m a i n s l e a d
A cord cap may be installed on the mains lead for testing, service, and temporary
applications.
Following the cord cap manufacturer’s instructions, connect the yellow and green
wire to ground (earth), the brown wire to live, and the blue wire to neutral. Table 3
shows some pin identification schemes; consult an electrician if you have any
doubts about proper installation.
F I B E R O P T I C C A B L E
Fiber optic cable is connected to the FiberSource CMY150 using one of the
available fiber adaptor kits:
• P/N 91611035, for 75-350 x Ø1mm fibers. This has a diameter of 30mm and is
supplied with an adaptor ring that increases the adaptor diameter to 38mm so that it
will fit in the port of the FiberSource CMY150 fixture.
• P/N 91611034, for 350-800 x Ø1mm fibers. This has a diameter of 38mm.
Wire (EU)
Wire (US)
Pin
Marking
Screw (US)
brown
black
live
“L”
yellow or brass
blue
white
neutral
“N”
silver
yellow/green
green
ground green
Table 3: Cord Cap Connections