background image

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Install in accordance with the manufacturer’s instructions.

8)  Do  not  install  near  any  heat  sources  such  as  radiators,  heat 
registers, stoves or other apparatus that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wider blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched particu-
larly at plugs, convenience receptacles, and the point where they exit
from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12)  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is
required when the apparatus has been damaged in any way, such as
a power supply cord or plug is damaged, liquid has been spilled, or
objects  have  fallen  into  the  apparatus,  the  apparatus  has  been
exposed to rain or moisture, does not operate normally, or has been
dropped.  This  installation  should  be  made  by  a  qualified  service 
person and should conform to all local codes.

13) Low Voltage Connections: The installation shall be in accordance
with  the  applicable  provisions  of  the  National  Electrical  Code
ANSI/NFPA  70, Article  800.90  and  Canadian  Electrical  Code  Part  1,
Section 60-504.

   TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
   COVER OR BACK. NO USER SERVICEABLE PARTS INSIDE. REFER
   SERVICING TO QUALIFIED SERVICE PERSONNEL.

   WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO 
   NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

This installation should be made by a qualified service person

and should conform to all local codes. 

WARNING - Do not install the unit in an environment where the

operating ambient temperature exceeds 185° F (85° C). The ventila-
tion should not be impeded by covering the unit with items, such as
newspapers, table-cloths, curtains, etc. No naked flame sources,
such as lighted candles should be placed on the apparatus.

WARNING - Do not interconnect multiple power supply 

outputs. 

Never use more than two power supplies within a

TBus channel. Never use more than one 60 watt remote
power supply on each TBus channel

. Do not connect additional

loads which would exceed the marked output current rating of the
power supply.

WARNING - The apparatus shall not be exposed to dripping or

splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.

WARNING - Use only a Certified power cord and plug (coupler /

mains) assemblies for location installed.

WARNING - Power cord is regarded as main disconnect.

WARNING - The appliance coupler (power cord/ mains) shall

remain readily operable. Its socket-outlet must be installed near the
equipment and shall be easily accessible.

WARNING - For safety, never put NVT signals in the same 

conduit as high-voltage wiring. 

Each of the TBus outputs are 56VDC, class2 (SELV). Each are cur-
rent-limited to deliver not more than 1A.

The NV-ER1816i TBus Receiver Hub, and its NV-PS56-250W auxiliary
power supply when provided, are each in a 1U rackmount enclosure.
Each is provided with an IEC380-C14 power inlet and UL approved
type SPT-2, SVT, or SJT, 18/3 AWG Min. 300VAC, 60° C Max 6 ft (1.8
m)  line-cord.  One  end  with  IEC380-C13  appliance  coupler  and  the
other end with NEMA 1015P or equivalent for your country.

Input Voltage is 100 ~240 VAC 50-60 Hz.

UL Listed to IEC/UL 60950-1 Complies with FCC part 15A limits 

IMPORTANT SAFETY INSTRUCTIONS

Page 1 of 25

Complete Installation Guide

Sixteen Port PoE+ Receiver Hub

Model NV-ER1816i

Network Video Technologies

(+1) 650.462.8100 • +44 (0) 208 977-6614

nvt.com • [email protected]

1

NV-ER1816

2

1

3

1

4

1

5

1

6

1

11

2

3

4

5

6

7

8

9

0

1

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Power

16-Port Ethernet Receiver

USE ONL

WITH A 250V FUSE

(no an

alog

 / no ether

net)

OUTPUTS:  56VDC       1AMP MAX. PER PORT,  4.5A MAX, TOTAL

Summary of Contents for NV-ER1816i

Page 1: ...o not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers table clot...

Page 2: ...6 VDC power supply can be optionally augmented by an external 250 watt auxiliary power supply supporting redundancy and or higher power applications The NV ER1816i is backed by NVT s award winning cus...

Page 3: ...Power LEDs on both Transceivers will return to a steady on condition and their green TBus Link LEDs will illuminate indicating a successful Join One TBus Link LED will remain on solid The other may wi...

Page 4: ...deration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate con...

Page 5: ...plied mounting brackets to the TBus Hub chassis using the supplied screws Note that the brackets allow the Hub to be mounted with either the front or rear facing out Connect the TBus wiring from as ma...

Page 6: ...ans that multiple remote camera end transmitters may be connected together to one receiver at the control room Wire may be star topology daisy chained or any combination TBus supports virtually any ty...

Page 7: ...rt that is sent in the direction of the camera That Report is monitored and passed on by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers each...

Page 8: ...we have up to 13V of allowable voltage drop on the wire The voltage will dip in proportion to the remote camera load The graph below shows what PoE power distances are supported for various loads and...

Page 9: ...com Network Video Technologies 1 650 462 8100 44 0 208 977 6614 nvt com info nvt com 1 000 ft 700 ft 500 ft 10 000 ft 7 000 ft 5 000 ft 3 000 ft 2 000 ft 100 ft 300 ft 200 ft 20 000 ft 1 000 m 700 m 5...

Page 10: ...y wire any wire IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Figure 5 Sixteen Cameras Star Topology 328ft 100m Cat5 SFP Port Hybrid DVR or NVR LAN WAN...

Page 11: ...t 100m IP Cameras Eight NV ET1804s Eight NV ET1801s NV ER1816i NV PS56 250W 250W Auxiliary Power Supply 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router SFP Port Network Video Technologies 1...

Page 12: ...re 9 Mixed Media 328ft 100m Cat5 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router UTP wire Coax Coax IP Camera NV ET1801 NV ER1816i NV ER1816i NV ER1816i 328ft 100m Cat5 Hybrid DVR or NVR LA...

Page 13: ...ing Cat5 328ft 100m RJ45 Cat5 Hybrid DVR or NVR LAN WAN Switch or Router Laptop for diagnostics any wire IP Camera NV ET1801 NV ER1816i Cat5 328ft 100m RJ45 any wire IP Camera NV ET1801 NV ER1816i Fig...

Page 14: ...rs Each power supply within a multi output unit is intended to support one and only one TBus Hub WARNING For safety never use more than one Auxiliary Power Supply with each NV ER1816i Receiver Hub DUA...

Page 15: ...Open your web browser and point it to https 192 168 254 1 which is the factory default address of the NV ER1816i Hub For best results please use the latest version of Internet Explorer with the latest...

Page 16: ...Submit The NV ER1816i supports one username and password 1 NV ER1816 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Auxiliary Join Link 10 100 1000 10 100 1000 Main Power 16 Port Ethernet Receiver JoinButton F...

Page 17: ...on a naming description field is available The hub will remember each entered description associated with every transmitter MAC address This memory is non volatile TBus devices must be Joined to commu...

Page 18: ...re 22 Power Page Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 0 Channel 1 Watts 0 50 45 40 35 30...

Page 19: ...iver Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 1 Figure 23 Monitor Page Rear Parking Lot Camer...

Page 20: ...lick Restore Firmware Upgrade Firmware upgrades will be available from time to time on the nvt com website For security most CCTV LANs are closed not accessible to the internet To avoid this issue fir...

Page 21: ...unable to perform this Switch configuration then NVT recommends you instead manually configure the NV ER1816i to generate an IGMP Report for each multicast camera See below If your network has no IGMP...

Page 22: ...Transmitter Netw ork Video Technologies Link Data 1 PoE Data 4 PoE Data 3 PoE Data 2 PoE 50W PoE n o Eth er ne t no an alog Quality 10 100 PoE 56VDC JOIN LINK NV ET1804 Ethernet Transmitter Netw ork...

Page 23: ...NV PS56 60W 56V DC power supply 60 watts with IEC line cord NV PS56 90W 56V DC power supply 90 watts with IEC line cord Do not use with NV ER1816i NV BNCT BNC T adaptor NV EC4BNC 1 4 BNC splitter ada...

Page 24: ...ng connectors and rack ears Shipping weight 10 37 lbs 4 70 Kg Operating storage temperature 40 F to 185 F 40 C to 85 C 20 to 85 relative humidity non condensing Generated heat Under full 220W load hub...

Page 25: ...obligation on the part of NVT with respect to any of the products In the event that any of the products is dam aged altered or modified without the express written consent of NVT any warranty for tho...

Reviews: