background image

Checking the Collar Contact

The Micro B collar receiver uses the patented Contact Measurement 
System (CMS).

A LED on the collar indicates if there is a contact with the dog's skin for 
a safe and effective training.

The CMS makes it possible to avoid any accidental overstimulation 
when there is no direct contact (due to bridging electricity).

While the CMS is checking for contact, the LED lights flash quickly and 
alternatively.

The CMS is active for 2 minutes after switching the collar on.

When there is correct contact, one LED blinks twice every 3 seconds.

Press on any button on the transmitter or on the FingerKick to stop the 
CMS.

10   |   Micro B Collar Receiver - User Manual - EN - 1.0

Pairing the Collar Receiver with a Transmitter

1.

Position and hold the magnet (standalone or in the transmitter) next to 
the 

ON / OFF / synchronizing point

 of the receiver.

2.

Wait until the LEDs blink quickly and simultaneously.

3.

Move the magnet and the transmitter at least 1 meter away.

4.

Within 10 seconds, press the simulation button on your remote or on the 
connected fingerkick.

5.

Press the button again to make sure the pairing is done.

6.

Press the stimulation button and check that the collar reacts.

 

Micro B Collar Receiver - User Manual - EN - 1.0   |   11

Summary of Contents for Micro B

Page 1: ...MICRO B COLLAR RECEIVER USER GUIDE EN ...

Page 2: ...cking the Collar Contact 10 Pairing the Collar Receiver with a Transmitter 11 Unpairing the Collar Receiver 12 Pairing the Collar Receiver via Bluetooth 13 Charging the Collar Receiver 14 Precautions for Use 16 Troubleshooting 17 Checking the Stimulation Operation 18 Recycling 19 Warranty 20 Conformity 21 2 Micro B Collar Receiver User Manual EN 1 0 ...

Page 3: ... of high quality stainless steel It is compatible with all transmitters from Martin System It is easy to switch on and off Specifications Dimensions Weight Power supply Frequency Antenna Operating temperature 35 x 55 x 22 mm 34 g 3 7 V 200 mAh Lithium Polymer 869 5 MHz Integral 20 C to 40 C Micro B Collar Receiver User Manual EN 1 0 3 ...

Page 4: ...e of your transmitter The Micro B collar receiver is equipped with A buzzer A vibrator A stimulation system The Micro B collar receiver operates in 4 different default modes Clicker level 0 Stimulation flash nick continuous and rising Tone with vibration and stimulation flash nick continuous and rising Warning tone and vibration followed by tone vibration and continuous stimulation 4 Micro B Colla...

Page 5: ... contact points made of marine grade stainless steel that greatly reduces the risk of chemical necrosis The smallest receiver with the longest battery life The Martin System patented NHT Transformer is about 1 8th the size of a standard transformer with the same capacity of stimulation and consistent reliable stimulation The main benefits of using a NHT Transformer are The smallest receiver with t...

Page 6: ...res the conditions of the dog s skin 20 times per second It adapts the output stimulation level to ensure a constant and reliable sensation felt by the dog This avoids the risk of accidental overstimulation of the dog due to constantly changing environmental factors 6 Micro B Collar Receiver User Manual EN 1 0 ...

Page 7: ...how for different transmitters The location of the magnet The range of the collar receiver The given range is valid in optimal conditions For more detailed information please check the user guide of your transmitter Micro B Collar Receiver User Manual EN 1 0 7 ...

Page 8: ...dy for use WARNING If the tone does not start with the flashing of the LEDs this means that the battery is low and you should recharge it as soon as possible TIP Do not leave the magnet too long next to the ON OFF synchronizing point or the pairing process starts Switching the collar receiver OFF 1 Slide the magnet standalone or in the transmitter next to the ON OFF synchronizing point of the rece...

Page 9: ...erly If the strap is too loose the contact points will not be in contact with the dog s skin and the dog will not feel the stimulations If the strap is too tight the dog will have difficulty breathing 4 Use the CMS Contact Measurement System to fit the collar as loosely as possible while ensuring a good contact with the skin Micro B Collar Receiver User Manual EN 1 0 9 ...

Page 10: ...e to avoid any accidental overstimulation when there is no direct contact due to bridging electricity While the CMS is checking for contact the LED lights flash quickly and alternatively The CMS is active for 2 minutes after switching the collar on When there is correct contact one LED blinks twice every 3 seconds Press on any button on the transmitter or on the FingerKick to stop the CMS 10 Micro...

Page 11: ...it until the LEDs blink quickly and simultaneously 3 Move the magnet and the transmitter at least 1 meter away 4 Within 10 seconds press the simulation button on your remote or on the connected fingerkick 5 Press the button again to make sure the pairing is done 6 Press the stimulation button and check that the collar reacts Micro B Collar Receiver User Manual EN 1 0 11 ...

Page 12: ... magnet at least 1 meter away for about 3 seconds 4 Slide again the magnet standalone or in the transmitter next to the ON OFF synchronizing point of the receiver The LEDs stop flashing quickly and simultaneously The corresponding pairing is erased You can pair the Micro B collar receiver with up to 4 transmitters ID codes that is both sides of 2 PT3000 devices The transmitters are paired in the o...

Page 13: ... or press the sign in the upper right corner of the application screen 5 Tap on the Micro B device The device connects to your collar receiver 6 Accept the pairing The LEDS flash quickly on the collar receiver to confirm the pairing 7 In the next 30 seconds and to ensure the pairing with the proper collar receiver slide again the magnet next to the ON OFF synchronizing point of the receiver A gree...

Page 14: ... USB port of a computer A LED on the charger module lights continuously 3 Switch the Micro B collar receiver OFF 4 Plug the collar receiver on the charger module aligning the red dot on the collar receiver with the red dot on the charger module If the receiver is correctly placed the battery automatically charges 14 Micro B Collar Receiver User Manual EN 1 0 ...

Page 15: ...r receiver is inserted the wrong way in the charging module or the charging module is not powered 5 Check the LED on the collar receiver Flashing the battery is charging Continuous the battery is charged Micro B Collar Receiver User Manual EN 1 0 15 ...

Page 16: ...pletely before using a collar If the skin condition does not improve consult a veterinarian Every week disinfect the dog s neck and the contact points Use a sponge or a towel soaked with a disinfecting solution If the dog is in poor health consult a veterinarian before using a training collar To properly use this product you need a minimum of basic training such as sit lie down and some knowledge ...

Page 17: ...he battery of the collar receiver may be fully discharged Recharge the collar receiver on the charging module If it is fully discharged charge it for about one hour before trying to switch it on The collar receiver does not respond when you press a button The devices may be unpaired Pair again the devices Check the operation at various distances If it is a range problem replace your transmitter ba...

Page 18: ... to the contact points 2 Send one or more stimulations with your remote control If the receiver is working correctly the indicator lamp illuminates with each impulse the higher the level the brighter the illumination If the indicator lamp does not light for levels higher than 1 contact your retailer 18 Micro B Collar Receiver User Manual EN 1 0 ...

Page 19: ...and not thrown in the waste bin If you are no longer using this material or if it cannot be repaired do not throw it away in the usual household rubbish Return it to the vendor or contact Martin System customer service for further information Micro B Collar Receiver User Manual EN 1 0 19 ...

Page 20: ...he damage to the product as a result of negligence or an error on the part of the user The damage to the product as a result of repairs made by non authorised persons The liability for damage caused by the improper use of the product or a breakdown In the case of a defect the device will at Martin System discretion be repaired or exchanged To benefit from this warranty you must send to Martin Syst...

Page 21: ...irective No 1999 5 CE of 07 04 99 And complies with the following standards SAFETY art 3 1 a EN 60950 EMC art 3 1 b EN 300 489 3 V1 4 1 SPECTRUM art 3 2 EN 300 220 3 V1 1 1 Place and date of this document Lantin 15 March 2019 MARTIN SYSTEM Rue Joseph Martin 35 4450 LANTIN BELGIUM Signed by or for the manufacturer Name Michael Bellon Position Director Micro B Collar Receiver User Manual EN 1 0 21 ...

Page 22: ...Notes 22 Micro B Collar Receiver User Manual EN 1 0 ...

Page 23: ......

Page 24: ...Rue Joseph Martin 35 B 4450 Lantin Belgium 32 0 4 263 96 05 info martinsystem com www martinsystem com ...

Reviews: