Align  the  Black  Pips  on  the 

handle with the Yellow 

 

Slide  the  selector  inwards  to 

the Compress position

 

Rotate handle clockwise until it 

clicks a few times

 

Step 3 

-

 Take the Reading

 

 

Press and hold   to display the moisture content of 

the sample. Keep holding the button until the reading 

has stabilised. Releasing  

 

will freeze the value for 

approximately 7 seconds, note and record this value 

as required. 

 

 

To change the crop type:

 

Display Codes

 

_ _ _ 

   

 

Standby mode

 

 

-

 R

   

 

Under measurement range

 

 

 

 

The sample is too dry or too cold. Can also display if the 

  

 

 

 

sample is less than 10ml or not compressed.

 

 

-

 R       

 

 

Over measurement range

 

 

 

 

The sample is too wet.

 

 

ATC 

(flashing) 

 

Automatic Temperature Correction (ATC) deactivated

 

 

+/

-

    

 

   

 

Crop calibration has been adjusted with a –ve or +ve bias 

 

 

     

 

 

      

Battery indicator

 

 

Press 

  to  put  instrument  in 

standby mode

 

Use 

Λ

 or 

V

 to scroll to the crop 

Press and release  

 

+

 

_ _ _

 

Bluetooth on

 

Summary of Contents for Grainmaster i2-S

Page 1: ...Martin Lishman Grainmaster i2 S Professional Crop Moisture Measurement Distributed by Martin Lishman Ltd Tel 44 0 1778 426600 www martinlishman com Instruction Manual GRN3000i2 S...

Page 2: ...2 Other products in the Martin Lishman range See our website for further details www martinlishman com...

Page 3: ...hip your moisture meter with the latest firmware but updates will become available You can update your meter with the use of the included USB cable and a Windows PC If you are using the Grainmaster mo...

Page 4: ...usted manually Page 9 Display Bias Set Always use Automatic Temperature Correction ATC ATC adjusts readings if a sample is not at 20 C The default setting is ATC switched ON Page 10 Display flashing A...

Page 5: ...Standby Mode Optional External Probe Socket USB Socket Meter Functions Items supplied Grain Hopper Yellow Black Pips Cleaning Brush Grinder Compressor Quick Check Grain Cup Grain Cell Spare Grinder B...

Page 6: ...Ensure the Grain Cell is clean Align the Black Pips on the handle with the Yellow Slide the selector inwards to the Compress position Rotate handle anti clockwise until it clicks a few times Slide th...

Page 7: ...roximately 7 seconds note and record this value as required To change the crop type Display Codes _ _ _ Standby mode U R Under measurement range The sample is too dry or too cold Can also display if t...

Page 8: ...3 27 4 30 0 Sorghum Milo Ground 10 2 11 7 12 4 13 1 13 9 14 6 15 4 15 6 16 3 17 1 17 9 18 7 19 6 20 9 22 2 23 7 25 4 Soya Beans Ground 7 4 8 2 8 8 9 7 10 4 11 1 11 8 12 0 12 6 13 4 14 3 15 2 16 0 17...

Page 9: ...ate for each crop and stored in the instrument s memory until removed as above Bias adjustment can also be made when using the Moisture Temperature or Bale Moisture Probes see Page 14 Temperature read...

Page 10: ...rature Correction ATC corrects the moisture reading automatically Even with ATC on the grain sample and the meter Grain Cell need enough time to reach close temperature equilibrium If there are extrem...

Page 11: ...meter version information will appear on screen before entering the setup menu The button Skip is used to navigate through the setup menu The and V buttons are used to change the selected parameter T...

Page 12: ...e battery if not used for long periods When battery power is low displays A spare battery is included with the meter Separate the two halves of the unit by twisting the yellow locking ring anticlockwi...

Page 13: ...t Quickcheck readings will reflect this Example Quickcheck reading is 17 1 cell temperature is 17 C wheat calibration is biased 0 5 The reading is derived from 16 3 Quickcheck value at 20 C 0 5 bias 0...

Page 14: ...moisture probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow a few minutes to stabilise Connect the probe to the me...

Page 15: ...emperature probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow the temperature to stabilise Connect the probe to th...

Page 16: ...he cost of replacement or repair The manufacturers and Martin Lishman Ltd will not be liable for any consequential or indirect loss suffered by purchasers or users of the unit whether this loss arises...

Reviews: