4
MAINS CONNECTIONS
The M3 is supplied with a captive mains lead with an integral U.K. BS1363
3 pin plug.
Should the moulded plug be removed and another plug
substituted the cable must be re-wired as below.
GREEN/YELLOW
-
EARTH
BROWN
-
LIVE
BLUE
-
NEUTRAL
WARNING: The M3 Controller must always be operated with the mains
safety earth connected.
The M3 is supplied from the factory in either 100-120V or
200-240V versions
Mains voltage tol/- 10% on each setting
Fuse: - type ‘T’ semi-delay 160mA (L) 100-120V
Fuse: - type ‘T’ semi-delay 160mA (L) 220-240V
NO ATTEMPT SHOULD BE MADE BY THE USER TO CHANGE THE
MAINS OPERATING VOLTAGE FROM THAT SUPPLIED, REFER TO
QUALIFIED PERSONNEL ONLY.
Martin Audio – M3 System Controller
E
NGLISH
3
This equipment must be earthed.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN
OR MOISTURE
It should not be necessary to remove any protective earth or signal cable
shield connections.
!
CONTENTS
<
>