RPT-30 Transmitter
FACTORY TEST DATA
Customer: _______________________________________________________________________
Address: ________________________________________________________________________
Serial No.:__________ Frequency #1 (F1):___________ Frequency #2 (F2):___________
140 - 200 MHz
200 - 480 MHz
TP1
0.35 - 0.70
TP1
0.25 - 0.50
TP2
0.40 - 0.80
TP2
0.20 - 0.60
TP3
NOT USED
TP3
0.60 - 1.20
TP4
0.25 - 0.50
TP4
0.45 - 0.90
TP5
0.30 - 0.60
TP5
0.80 - 1.60
q
8 volt regulator (7.45 - 7.65)
q
Audio Compressor Meter set at 0 VU
q
Limiter
Set
q
Encode frequency set at 27 Hz.
q
Encode frequency set at 1 KHz. deviation
q
Set power on 120 volt AC operation at __________watts
q
DC voltage on 120 volt AC operation (13.5 volts DC)
q
Response within specifications
q
Distortion within specifications
q
Signal to noise within specifications
q
Metering
satisfactory
Test Equipment
______________________________________
Frequency Counter, HP Model 5383A
DATE
Deviation Monitor, Wavetek Model 4101
______________________________________
SIGNATURE
Summary of Contents for RPT-30
Page 3: ...This page intentionally left blank...
Page 13: ...STALLING ANTENNAS KEEP AWAY FROM POWER LINES...
Page 19: ...This page intentionally left blank...
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......