background image

  ME990-3F-VRK 

  COMPLETE VALVE REPAIR KIT 

  FOR: ME990-3F 3" SINGLE FLANGE  

INTERNAL VALVE 

Marshall Excelsior Company 

1506 George Brown Drive Marshall, MI 49068 

Phone (269) 789-6700  Fax (269) 781-8340 

www.marshallexcelsior.com 

 

The contents of this publication are for informational purposes only.  While every effort has been made to ensure accuracy, 

these contents are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services 

described herein or for their use or applicability.  Marshall Excelsior Co. reserves the right to modify or improve the designs 

or specifications of such products at any time without notice.  The MEC™ logo is the trademark of Marshall Excelsior Co.  

 

Form #1133 

Rev A 3/7/2018 

!!!WARNING!!! 

READ AND UNDERSTAND ALL INSTRUCTIONS INCLUDED WITH THIS REPAIR KIT 

RELIEVE ALL PRESSURE FROM SYSTEM BEFORE REMOVING VALVE FOR SERVICE 

 

NOTE:

 Numbers in brackets [ ] refer to the number 

in the valve component list. 
 

WARNING:

 

These products contain a chemical 

known to the state of California to cause cancer and 
birth defects or reproductive harm  

 

A.

 

Disassembly

 

 

1.

 

EVACUATE ALL PRESSURE FROM 
SYSTEM BEFORE ANY DISASSEMBLY 
OR REPAIR. 

2.

 

Remove (8) Bushings [19] from Valve Body 
[1] and discard (not shown).

 

3.

 

Remove (2) Cap Screws [2] from Screen Cap 
[3] and discard. 

4.

 

Remove Screen Cap [3] and Screen [4]; retain 
components. 

5.

 

Remove (4) Cage Screws [5] from Valve 
Cage [6] and discard. 

6.

 

Remove Valve Cage [6] and Cage Bushing [7] 
and discard. 

7.

 

Remove Spring Guide [8], Closing Spring [9] 
and Spring Washer [10] and discard. 

8.

 

Remove Lock Nut [11] and Bleed Disc [12] 
and discard. 

9.

 

Remove Valve Poppet [13] and discard. 

10.

 

Remove Excess Flow Spring [14] and retain. 

11.

 

Remove Spring Seat [15] and Stem [16] and 
discard. 

12.

 

Remove Guide Bearing [17] and discard. 

13.

 

Remove Cam Pin [19] and Cam [20] from 
Gland Assembly [18] and discard. 

14.

 

Remove Gland Assembly [18] and discard. 

15.

 

Inspect Valve Body [1] and clean if necessary, 
be sure interior is free of dirt, residue and 
foreign particles. 

 

 
 

 

 

B.

 

Reassembly

 

 

1.

 

Apply Loctite #242 or equivalent thread 
locker to gland threads of Body [1]; install 
new Gland Assembly [18]; see recommended 
orientation below. 

2.

 

Install new Cam [20] and new Cam Pin [19] 
onto Gland Assembly [18]. 

3.

 

Install new Guide Bushing [17] into Body [1] 

4.

 

Install new Spring Seat [15], retained Ex-Flow 
Spring [14], and new Valve Poppet [13] onto 
new Stem [16] in order and orientation shown. 

5.

 

Install new Bleed Disc [12] and new Lock Nut 
[11] onto Stem [16]. 

6.

 

Install Stem Assembly [11-16] into Body [1]. 