14
■
Check Field
Use the check field modes for monitor calibration or to analyze individual color components of an image. In Monochrome mode, all color is disabled and only a grayscale
image is shown. In Blue, Green, and Red check field modes, only the selected color will be shown.
Use the following procedure when calibrating the monitor to SMPTE color bars with the following procedure:
1.
Allow the monitor to warm up for at least 5-10 minutes.
2.
Display SMPTE split-field color bars on the monitor using an external source.
3.
Enable
Monochrome mode
.
4.
Locate the pluge pattern (super black, black, and gray bars) at the lower-right corner of the screen. Adjust the
Brightness
knob until there is no visible
difference between the super black and black bars, but the gray bar is still visible.
5.
Adjust the
Contrast
knob until an even grayscale appears along the top bars.
6.
Disable
Monochrome mode
.
7.
Enable
Blue Check Field mode
and adjust the
Color
knob so that the outermost bars (white and blue) appear to match in brightness.
8.
Disable
Blue Check Field mode
.