OWNER’S MANUAL 

 

MODEL DH5-3 & DH5-3B – HEATED HOLDING UNIT     
 

 

160805 RV110612 

1

 

Copyright © 2012 Marshall Air Systems, Inc. 
All Rights Reserved. 

 

PRE-INSTALLATION 
 

  1.  The Heated Holding Unit is packaged to minimize the risk of shipping damage. Immediately upon receipt, 

make certain to inspect the unit for damage. 

FILE ALL CLAIMS WITH THE FREIGHT CARRIER. 

 
  2.  Unpack and inspect the unit. 

IF ANY CONCEALED DAMAGE, FILE ALL CLAIMS WITH THE FREIGHT 

CARRIER. 

 

FINAL INSTALLATION 

 

  1.  Unpack unit and remove all protective paper or plastic covering from metal parts. 
 
  2.  Place holding unit on stable base. 
 
  3.  Plug unit into 120v receptacle rated for 20 amps. 
 

TO USE THE HOLDING UNIT 

 
  1.  Turn on the power switch. The unit is ready to use after a 30 minute preheat period. 
 
  2.  The unit is factory set for a temperature of 250°f for both upper and bottom heaters.  The factory set hold 

time is 45 minutes with the alert happening at the 40:30 minute time. If a new setting is required, follow the 
instructions in Figure 3 to adjust the settings.  

DO NOT SET THE TEMPERATURE HIGHER THAN 290° F.  

DOING SO WILL CAUSE DAMAGE TO THE UNIT. 

 
   

3.  The unit can hold up to three 1/3 size pans 2 1/2" deep, two 1/2 sheet pans, one full pan or one 1/2 sheet 

pan per deck. Each controller display correspond to a 1/3 size pan. Place a product pan in one of the 3 
possible positions and press the associated timer button (see User Interface below) to begin timer. 

   
   4.  The corresponding display will then show the remaining holding time.  Once the corresponding holding time 
        reaches 40:30 minutes of hold time it will sound a warning alert. 
 
   5.  Once the corresponding holding time reaches the final minute, the display will change from minutes to  
        seconds.   
   
   6.  Once the corresponding holding time reaches 0, a warning alert will sound.  Press and release the 
        corresponding pan timer button to stop. 
 
   7.  Any timer can be stopped at any time during the holding period, by pressing and holding the pan timer button 

for 2.5 seconds. 

 

 
 
 
 
 
 
 
 
TIMER/TEMPERATURE CONTROLLER OPERATION 

Summary of Contents for DH5-3

Page 1: ...unit is controlled by an integrated time temperature controller located on the front of the heated holding cabinet The control determines the intensity of top and bottom heaters The integrated time t...

Page 2: ......

Page 3: ...NAL INSTALLATION 1 TO USE THE HOLDING UNIT 1 TIMER TEMPERATURE CONTROLLER OPERATION 2 DAILY MAINTENANCE 3 MONTHLY MAINTENANCE 3 TROUBLESHOOTING 4 REPLACEMENT PARTS 5 ILLUSTRATIONS OVERALL DIMENSIONS D...

Page 4: ......

Page 5: ...t the 40 30 minute time If a new setting is required follow the instructions in Figure 3 to adjust the settings DO NOT SET THE TEMPERATURE HIGHER THAN 290 F DOING SO WILL CAUSE DAMAGE TO THE UNIT 3 Th...

Page 6: ...g flashes last 10 of the holding period with an audible alert at the start of the last 10 000 Holding period has elapsed Product to be discarded flashes with audible alert DISPLAY TEMPERATURE The unit...

Page 7: ...UNIT DAILY MAINTENANCE 1 Turn off the unit and allow it to cool for 20 minutes 2 Pans and or pan covers should be removed washed in mild multi purpose detergent rinsed and sanitized 3 Clean unit and...

Page 8: ...ECTIVE SOLID STATE RELAY A PLUG IN B RESET BREAKER CALL AN ELECTRICIAN IF TRIPPED TWICE C REPLACE DEFECTIVE CORD D TURN CONTROLLER ON E REPLACE DEFECTIVE SOLID STATE RELAY 2 LOW PRODUCT TEMPERATURE A...

Page 9: ...80 Connector Strain Relief 1 Figure 2 504023 Relay Solid State 25A 2 Figure 2 Schematic 158678 Panel Rear Cover 1 Figure 2 501873 Fan Cooling Boxer 115VAC 1 Figure 2 Schematic 502075 Cord 14 3 SJTOW W...

Page 10: ...served RV110612 160805FIG1 OVERALL DIMENSIONS DH5 3 DH5 3B FIGURE 1 D E T S I L K E T R E T N I CM US N S F T E S T I N G L A B O R A T O R Y A N N A R B O R M I C H INTEGRATED TIME TEMPERATURE CONTRO...

Page 11: ...IN RELIEF 502080 4 2 RELAY SOLID STATE 25A 504023 5 1 PANEL REAR COVER 158678 6 1 FAN COOLING BOXER 115VAC 501873 7 1 CORD 14 3 SJTOW W STR 120V PLUG 502075 8 1 COVER 2 5 PAN 160294 9 4 FOOT BLK RUBBE...

Page 12: ...WILL SHOW THE CURRENT SETTING USE UP OR DOWN ARROW BUTTONS TO SELECT ONE OF THE SIX AVAILABLE MODES 123 FOR TIME DISPLAY MODE ALL TIMERS ARE INDEPENDENT OF EACH OTHERS AND REMAINING HOLD TIME IS INDIC...

Page 13: ......

Reviews: