EMC Declaration 

 

IEC 60601-1-2

2014 ME EQUIPMENT and ME SYSTEMS identification, marking and 

documents for Class B product 

Instructions for Use 

 
The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments. 
 
Warning

Do not use near active HF surgical equipment and the RF shielded room of an ME system 

for magnetic resonance imaging, where the intensity of EM disturbances is high. 
 
Warning

 Use of this equipment adjacent to or stacked with other equipment should be avoided 

because it could result in improper operation.  If such use is necessary, this equipment and the other 
equipment should be observed to verify that they are operating normally. 
 
Warning: Use of accessories, transducers and cables other than those specified or provided by the 
manufacturer of this equipment could result in increased electromagnetic emissions or decreased 
electromagnetic immunity of this equipment and result in 

improper operation.” 

 
Warning

Portable RF communications equipment (including peripherals such as antenna cables and 

external antennas) should be used no closer than 30 cm (12 inches) to any part of the thermometer, 
including cables specified by the manufacturer. Otherwise, degradation of the performance of this 
equipment could result. 
 
If any

a list of  all cables  and  maximum  lengths  of cables  (if applicable), transducers  and  other 

ACCESSORIES that are replaceable by the RESPONSIBLE ORGANIZATION and that are likely to 
affect  compliance  of  the  ME EQUIPMENT  or  ME SYSTEM  with  the  requirements  of  Clause  7 
(EMISSIONS)  and  Clause  8  (IMMUNITY).  ACCESSORIES may  be  specified  either  generically 
(e.g. shielded cable, load impedance) or specifically (e.g. by MANUFACTURER and EQUIPMENT OR 
TYPE REFERENCE). 
 
If any

the performance of the ME EQUIPMENT or ME SYSTEM that was determined to be 

ESSENTIAL PERFORMANCE   and  a  description  of  what  the  OPERATOR  can  expect  if  the  
ESSENTIAL PERFORMANCE  is  lost  or  degraded  due  to  EM  DISTURBANCES  (the  defined  
term  “ESSENTIAL PERFORMANCE” need not be used). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for T-210

Page 1: ...Version 1 7 10 20 UFR118 T 210 Infrared Thermometer User Manual...

Page 2: ...f Conformity 3 Specification 4 Symbol Descriptions 4 Important Safety Instructions 5 Parts Identification 6 Battery Installation 7 About Normal Temperature Fever 8 Unit Setting 9 Operation 9 Error Mes...

Page 3: ...11 2015 Medical electrical equipment Part 1 11 General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment and medical electrical...

Page 4: ...t direct sunlight and water during transportation Expected Service Life Five years Software Version UFR 1 1 Symbol Descriptions The following symbols may appear in this manual on the label on the devi...

Page 5: ...viduals The patrient is ther intended operator Temperature reading is for reference only CAUTION Please do not use a dilution agent alcohol or petrol to clean the unit Please use the device with care...

Page 6: ...6 Parts Identification...

Page 7: ...t socket or use a USB plug The device will need approximately eight hours to reach full charge A green strip will appear on the display during charging changing to a red strip when charging is complet...

Page 8: ...t temperatures measured from different sites even at the same time should not be directly compared Fever indicates that the body temperature is higher than normal This symptom may be caused by infecti...

Page 9: ...ce for 10 15 minutes prior to testing and room temperature should be 20 25 C To use the thermometer press the START STOP button All symbols will appear on the display and you will hear one short beep...

Page 10: ...99 5 3 10 short beeps with red LED when measurement reading is 37 5 99 5 or higher 4 3 short beeps with red LED if the device is unable to measure temperature Babies skin reacts very quickly to ambien...

Page 11: ...air under this warranty our authorised service agent must be advised of the fault within the period of the warranty This warranty only covers parts and labour service under normal operations Any defec...

Page 12: ...quipment and result in improper operation Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches...

Page 13: ...ected service life 2 Guidance and manufacturer s declaration electromagnetic emissions and immunity Table 1 Guidance and manufacturer s declaration electromagnetic emissions Emissions test Compliance...

Page 14: ...ltage variations on power supply input lines IEC 61000 4 11 0 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 1 cycle And 70 25 30 cycles Single phase at 0 0 250 cycle 50Hz 0 0 5 cycle At 0 45 90 135 1...

Page 15: ...1 8 0 3 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850...

Page 16: ...364296 sales marsdengroup co uk Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX www marsden wei...

Reviews: