Radiated RF 
IEC 61000-4-3

 

3 V/m 80 MHz to 2,5 
GHz 

3 V/m

 

vicinity of equipment marked 
with the following symbol: 

 

NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. 
NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and 
reflection from structures, objects and people. 

A)

 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and 
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted 
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an 
electromagnetic site survey should be considered.   

B)

 

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 

 
 
Recommended separation distance between portable and mobile RF communications 
equipment and the MHS-2500I. 
 

This scale is intended for use in an electromagnetic environment in which radiated RF disturbances are 
controlled. The customer or the user of the scale can help prevent electromagnetic interference by 
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) 
and the scale as recommended below, according to the maximum output power of the communications 
equipment. 

 

Rated maximum output 
power of transmitter 
 

W

 

Separation distance according to frequency of transmitter m

 

150 kHz to 80 MHz 

 

d = 1,2

80 MHz to 800 MHz 

 

d = 1,2

P

 

800 MHz to 2,5 GHz 

 

d = 2,3

P

 

0.01 

0.12 

0.12 

0.23 

0.1 

0.38 

0.38 

0.73 

1.2 

1.2 

2.3 

10 

3.8 

3.8 

7.3 

100 

12 

12 

23 

 

For transmitters rated at a maximum output power not listed above, the recommended separation distance d 
in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is 
the maximum output rating of the transmitter in watts (w) according to the transmitter manufacturer. 
 
NOTE1) At 80 MHz and 800 MHz, the separation distance for the high frequency range applies. 
NOTE2)  These  guidelines  may  not  apply  in  all  situations.  Electromagnetic  propagation  is  affected  by 
absorption and reflection from structures, objects and people. 

 
 
 
 
 
 

 

Page 12 

Summary of Contents for MHS-2500I

Page 1: ...USER MANUAL MHS 2500I Please take time to read these instructions before starting to use the scale Version 1 0 05 17...

Page 2: ......

Page 3: ...of Graphic Symbols 5 Installing the Batteries 6 Before Using the Scale 7 Operation Basic Functions 8 Operation Advanced Functions 9 EMC Guidance and Manufacturer s Declaration 10 Recommended Separatio...

Page 4: ...load capacity of 300kg which must not be exceeded Product Specification Model MHS 2500I Accuracy Class Class III Capacity Division 300kg x 100g Units of Measure Kg Function Keys ON ZERO TARE OFF HOLD...

Page 5: ...uld be assisted in using the device Do not exceed the maximum capacity of the scale The safety requirements and notes on appropriate use from the hoist manufacturer must also be observed The device mu...

Page 6: ...C Identification of manufacturer of medical product including address Type B Applied Part Dispose of old appliances separately from your household waste This product must be disposed of at a communal...

Page 7: ...ation Please follow these instructions for installing the batteries 1 Locate the battery cover on the 2 Slide the battery cover off back of the scale 3 Remove the battery housing 4 Install 6x AAA size...

Page 8: ...2500I is fitted to the hoist correctly and hangs straight A tilt of more than 3 during operation will cause the scale to display incorrect readings We do not recommend using the scale with a hoist ha...

Page 9: ...le will show zero and a minus reading when the item is removed HOLD BMI During weighing press this button once to lock and hold the weight reading on the scale To disable the Hold function press once...

Page 10: ...f time it will shut off automatically This function can be set to 120 sec 180 sec 240 sec 300 sec Press for three seconds to enter Setup mode will show on the display Press the ON OFF ZERO TARE button...

Page 11: ...or the user of this scale should ensure that it is used in such an environment Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment Guidance Electrostatic discharge ESD IEC...

Page 12: ...used in such an environment Immunity Test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 KHx to 80 MHz 3 Vrms Portable and mobile RF c...

Page 13: ...iated RF disturbances are controlled The customer or the user of the scale can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications...

Page 14: ...w zero range Check that nothing is on or catching the scale and retry Scale overload The scale s maximum capacity has been exceeded Please reduce the loading and try again Scale Underloaded The weight...

Page 15: ...Manufacturer s Declaration of Conformity Page 14...

Page 16: ...Page 15...

Page 17: ...mail sales marsdengroup co uk Manufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX...