STD2 (Standard 2) Series 

Unheated 

Model Lengths 36” –

 

144” 

 

 

14716 S. BROADWAY, GARDENA, CA 90248 ● Ph: (310)532-1555 Fax: (310)-532-3030 ● 

www.marsair.com

 

© Copyright Mars Air Systems, LLC 2014 

NOTE: MARS AIR SYSTEMS, LLC reserves the right to change specifications and product design without notice. Such revisions do  not entitle the buyer to corresponding changes, improvements, additions, or replacements 
for previously purchased equipment. 

 

MARS AIR SYSTEMS, LLC 

● 

GARDENA, CA 

● 

USA

 

VM, 05/21/21 

STD2

Series: Standard 2

72 2 U H OB

LENGTH OF UNIT

# OF MOTORS

U = UNHEATED

VOLTAGE CODE

COLOR

EXAMPLE

115v/1Ø

(A)

208/230v/1Ø

(D)

208/230v/3Ø

(G)

460v/3Ø

(H)

575v/3Ø

(I)

STD236-1U*-OB

5.1

2.5

1.8/1.6

0.8

0.7

STD242-1U*-OB

5.1

2.5

1.8/1.6

0.8

0.7

STD248-1U*-OB

5.1

2.5

1.8/1.6

0.8

0.7

STD260-2U*-OB

10.2

5.0

3.6/3.2

1.6

1.4

STD272-2U*-OB

10.2

5.0

3.6/3.2

1.6

1.4

STD284-2U*-OB

10.2

5.0

3.6/3.2

1.6

1.4

STD296-2U*-OB

10.2

5.0

3.6/3.2

1.6

1.4

STD2108-3U*-OB

15.3

7.5

5.4/4.8

2.4

2.1

STD2120-3U*-OB

15.3

7.5

5.4/4.8

2.4

2.1

STD2144-3U*-OB

15.3

7.5

5.4/4.8

2.4

2.1

* - Use corresponding letters in "Electrical Data" columns to complete the model numbers.
Alternate voltage codes with FLA (Full Load Amp) data:
277v/1Ø/60Hz (L) - 2.7A per motor

380-415v/3Ø/50Hz (W) - 1.1A per motor

220v/1Ø/50Hz (U) - 2.5A per motor
For total FLA, multiply motor FLA by # of motors.
Ampacity (MCA) = total FLA X 1.25

Electrical Data 

(FLA)

Single Phase

Three Phase

Unit Voltage  (Voltage Code)

Model

Distance from 

nozzel (in)

Avg. Core Velocity 

(FPM)

40

1207

80

856

120

710

160

637

200

588

Projection Velocity

STD236-1U*

MARS Air Systems, LLC certifies that the Air Curtains shown on this data 
sheet are  licensed to bear  the AMCA seal. The ratings shown are based 
on tests and procedures performed in accordance with AMCA Publication 
211  and  comply  with  the  requirements  of  the  AMCA  Certified  Ratings 
Program.

 

The  AMCA  Certified  Ratings  Seal  applies  to  airflow  rate,  average  outlet 
velocity,  outlet  velocity  uniformity,  velocity  projection  and  power  rating  at 
free delivery only.

 

NOTE:  Models  STD260-2,  STD264-2,  STD278-2,  STD296-3,  and 
STD2108-2 are not AMCA Certified. 

Unheated Data Sheet 

Applications: Environmental Separation (up to 12

’) and

 

Insect Control (up to 10

 

 

 

 

Features:  

 

1/2 HP Continuous Duty TEAO Motors 

 

Sleek self-contained one-piece heavy gauge corrosion proof paint  
lock metal design  

 

ETL Certified to conform to UL 507 (US) and CSA 22.2 (Canada) Standards (Indoor/Outdoor Use) 

 

AMCA Certified to AMCA 211 (see table above for models available) 

 

(4) 7/16” top and wall mounting holes provided, (2) on each end

 

 

Cabinet has sufficient strength for fastening to wall on both ends without intermediate support  

 

Adjustable air directional vanes with 40° sweep front to back 

 

Standard color is Obsidian Black 

 

Rust preventative electrostatic polyurethane powder coating 

 

5-year parts warranty 

 

Freight Included (FOB Continental USA) 

 

Proudly Made in the USA

 

Note: 

All STD2 (1) motor units 

up to 48”

 are shipped with the Motor Fan Assembly (MFA) factory installed inside the air curtain 

housing. For all other models, the MFA are shipped loose to minimize freight damage 

Mars Recommended Accessories (See Submittals for additional details):  

 

Door Limit Switches 

o

 

99-014, Combination mechanical switch, 250v, 1HP Max 

o

 

99-125, Industrial surface mounted magnetic switch (controller required) 

 

Controllers  

o

 

MCPA-

U*, Motor Control Panel, 120V control voltage (

 = # of Motors, * = Voltage Code) 

o

 

MCP-TD, Adjustable time delay, 1sec-100hr (panel required) 

o

 

MCP-24V, Low voltage control option (panel required) 

o

 

BMS-303, BMS for monitor and control (panel required with MCP-24V) 

Note: Dry contact provided in panel for monitoring motor. 24Vac signal provided from panel for controlling 

motor 

o

 

SK-UU, SimpleLink, 115V-230V, 1PH, 2Mtr & 1HP max, Integral Control, Nema1 (housing depth will 
be 

17 3/8” deep

 

Brackets 

o

 

B0004, 

Adjustable mounting bracket set, 3 ½” clearance

 

o

 

B0005, Adjustable mounting bracket set

, 7”

-

13” clearance 

 

o

 

B0041, Transom mounting bracket set for STD2 

 

Filters 

o

 

J21**- 

Ɨ, ¼” aluminum pressed frame bank filters (** = Model Length, Ɨ = # of Motors)

 

 

Clean Air Series Sections 

o

 

HEC2**-OB, HEPAC Section (** = Model Length) 

o

 

UVCS**-*-OB, UV Section (** = Model Length, * = Voltage Code) 

 

Severe Duty and Finish 

o

 

HSG-304SS-STD, 304 Stainless steel housing construction  

o

 

INS-WD-STD2, Washdown motor fan assembly, IP54 

o

 

INS-XP-STD2, Explosion resistant motor fan assembly, 
Class 1, Division 1, Group D 

Note: 

Washdown and explosion proof units will require higher motor 

amperage. Please specify at the time order for correct panel rating.

 

 

Sound Levels: (measured at 10’ 

in an open field) 

1 Motor Unit = 66 dBA, 2 Motor Unit = 68 dBA, 3 Motor Unit = 71 dBA, & 
4 Motor Unit = 73 dBA 

STD2 (Standard)

Series 2

Model Number

Nozzle Length

(in)

Length

(in)

Depth

(in)

Height

(in)

Motor

(hp)

Weight

(lbs)

Max Core Velocity 

at Nozzle (fpm)

Avg Velocity

(fpm)

Volume

(cfm)

Uniformity

(%)

Power Rating

(watts)

STD236-1U*-OB

36

36

13

11

1/2

60

5960

2206

1379

84

500

STD242-1U*-OB

42

42

13

11

1/2

65

4865

1945

1418

87

510

STD248-1U*-OB

48

48

13

11

1/2

70

4247

1730

1442

85

550

STD260-2U*-OB

60

60

13

11

Two 1/2

90

6737

2592

2700

93

940

STD272-2U*-OB

72

72

13

11

Two 1/2

120

5960

2206

2758

84

1000

STD284-2U*-OB

84

84

13

11

Two 1/2

125

4865

1945

2836

87

1020

STD296-2U*-OB

96

96

13

11

Two 1/2

135

4247

1730

2884

85

1100

STD2108-3U*-OB

108

108

13

11

Three 1/2

175

5960

2206

4137

84

1500

STD2120-3U*-OB

120

120

13

11

Three 1/2

185

4660

2084

4341

92

1570

STD2144-3U*-OB

144

144

13

11

Three 1/2

200

4247

1730

4326

85

1650

Note: Data above for 1725 RPM at 60 Hz, 50 Hz is 1425 RPM with a 17% 
reduction in the performance data.

* - Use corresponding letters in "Electrical Data" columns to 
complete the model numbers.

AMCA Certified Lab Data

Mechanical Data

1. The AMCA Certified Ratings Seal applies to airflow rate, average outlet velocity, outlet velocity uniformity, velocity projection and power rating at free delivery only. 
2. Rated data shown are only for base (unheated) units, as shown. 

 

Summary of Contents for STD2 Unheated 2 Series

Page 1: ...thout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA STD2 Unheate...

Page 2: ...tice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents Pa...

Page 3: ......

Page 4: ...A Proudly Made in the USA Note All STD2 1 motor units up to 48 are shipped with the Motor Fan Assembly MFA factory installed inside the air curtain housing For all other models the MFA are shipped loo...

Page 5: ......

Page 6: ...nged door type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical...

Page 7: ...6 STD SHOWN 3 Extended Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installa...

Page 8: ...itation Series utilizes 1 2HP and 1HP motors The Standard 2 High Velocity 2 and Extra Power 2 Series come standard with an air intake grille They can also be configured with an aluminum mesh air intak...

Page 9: ...nside the product to align with the stud spacing All hardware is field provided by others 4 Mount the product such that the discharge is 1 above the opening and all obstacles FIG 1 Note If the product...

Page 10: ...lied are wired correctly E Check that the inlet air supply and the discharge air supply are free of obstructions F Check that all air filter s and or air intake grille s are in place and installed pro...

Page 11: ...required for enclosure motor wheel and other components to minimize damage caused by exposure to the outdoor elements Contact factory for special construction and costing Freezer and Cooler Installat...

Page 12: ...on on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating below normal speed Apply p...

Page 13: ...ma 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Page 14: ...omer may be responsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars...

Page 15: ...DES A Air curtains for pedestrian entrances B Air curtains for vehicular entrances C Air curtains for large loading dock doors 1 2 RELATED SECTIONS A Section 05 50 00 Metal Fabrications Concealed stee...

Page 16: ...ol Panels F UL 1995 CSA 22 2 UL Standard for Safety Heating and Cooling Equipment Intertek Testing Services Listed for US and Canada G UL 2021 CSA 22 2 Standard for Fixed and Location Dedicated Electr...

Page 17: ...sh product specified two samples minimum size 6 25 inches 160 mm square representing actual product color and patterns G Manufacturer s Certificates Certify products meet or exceed specified requireme...

Page 18: ...ns and substitutions C Requests for substitutions will be considered in accordance with provisions of Section 01 33 00 2 2 AIR CURTAIN ASSEMBLIES A Motor Fan Assembly Design for easy removal assembly...

Page 19: ...e row by 10 5 8 inches high including discharge nozzle by width of unit plus 10 inches for manifolds 2 Mounting a Unheated Inside Mount b Heated Inside Mount c Unheated Outside Mount d Mount Location...

Page 20: ...nimum of 300 fpm 1 53 m s at 3 feet 914 mm from the floor 4 Air Inlet Grille and Filters a Location Front b Type Fixed air intake grille 1 Filter Aluminum mesh 1 4 inch 6 4 mm washable c Type Filter O...

Page 21: ...from floor 4 Air Inlet Grille and Filters a Location Front b Speed 2550 cu ft min 1200 L s minimum per motor fan assembly 1 Type Fixed air intake grille 5 Sound Pressure Level At 10 feet 3 m From Noz...

Page 22: ...to air curtain housing 9 Supply and return fittings on top of casing 10 Thermostat Wall mounted 110 Volt operation with heater on off selection 11 Thermostat Wall mounted 208 230 Volt operation with...

Page 23: ...assive Adaptive e Factory Integrated temperature control sensors No external thermostat required f Summer Winter modes g 24 7 timer h Maintenance schedule alerts i Status display showing date time tem...

Page 24: ...20 amps limit switch to control air curtain s as follows Automatic on off control activates air curtain when door is opened and turns off when door is closed Provide limit switch for direct control on...

Page 25: ...tight without warp or rack C Anchor air curtains securely in place to supports D Coordinate with sheet metal flashing as specified in Section 07 62 00 E Install joint sealants as specified in Section...

Page 26: ...manufacturer s instructions and as approved by Architect C Remove and replace damaged components that cannot be successfully repaired as determined by Architect 3 5 PROTECTION A Protect materials and...

Page 27: ...evisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Descriptio...