Remote Control Manual  -  

PS-81B / PS-101B

3

CLOCK

C

ON

 OFF

SET TEMP.

FAN SPEED

Indicators on remote controller

Transmission Indicator

Temp. display

Time display

Fan speed display

Sleep Display

Mode display

ON/OFF display

This transmission indicator lights when

remote controller transmits signals to the

indoor unit.

Displays the current operation mode. Including

AUTO(      ), COOL(      ), DRY(      ), HEAT(     )

(Not applicable to cooling only models), FAN 

ONLY (       )and back to  AUTO(       ).

Displays the temperature setting (17 C/62 F

  to 30 C/86 F

when you set the operating  

mode to FAN ONLY, no temperature setting is 

displayed.

Displayed by pressing the  ON/OFF  button.

Press the  ON/OFF  button again to remove.

The clock time is indicated only when no

AUTO-ON/OFF timer is set. When AUTO-

TIMER feature is operating, it displays the

AUTO-ON/OFF time. To check the current

time, press the CLOCK button, and the time

will display.

Indicate Timer on/off time(0    24 hours)

or clock time.

Displays the selected fan speed, AUTO

and three fan speed levels "        " (LOW)

"                " (MED) "                   " (HIGH)  

will be indicated. Displays AUTO when the 

operating mode is either AUTO or DRY.

Displayed by pressing  the SLEEP  button.

Press  the SLEEP button again to remove.

Note:

All displays on the remote controller are

shown for illustration purposes only.

3

8

Timer operation

   When you select the timer operation, the remote controller automatically

   transmits the timer signal to the indoor unit at the specified time. 

   Therefore,  keep the remote controller in a location from which it can

    transmit the signal to the indoor unit properly.  

   The effective operation time set by remote controller is limited in 24 hours.

CAUTIONS

1. TIMER  button

    Press the TIMER button, the remote

    displays 0.0  alongside either the TIMER

    ON or TIMER OFF indicator,  and will 

    flash.

2. TEMP/TIME button 

   Press  to set the desired time.

        Forward

        Backward

   

 

Press or hold the forward or backward

   button to change the Auto time by 0.5 

   hour increments, up to 10 hours, then 

   at 1 hour increments up to 24 hours.

   The selected time will register in seconds

   after setting.

3.  After setting the timer for TIMER ON and

    TIMER OFF, check the TIMER indicator

    on the display panel of the unit is 

    illuminated.

4. Cancel button(CANCEL)

    Press  the CANCEL button to cancel 

    the timer setting.

Preform steps 1, 2 and 3 to change the 

settings.

.

.

Canceling

Changing

.

.

AUTO

F

AUTO

AUTO

Lock Display

Displayed by pressing  the LOCK button.

Press  the LOCK button again to remove.

~

1

2

3

ON

 OFF

SET TEMP.

FAN SPEED

MODE

SLEEP

LED

CLOCK

CANCEL

TIMER

FAN 

RESET LOCK

.

Note:

 Some models have no MED Fan 

speed selection.

SWING

C

Summary of Contents for R09D/BGCE

Page 1: ...517 787 2100 www marsdelivers com www heatcontroller com Remote Control Manual Portable Room Air Conditioner Remote Control for PS 81B PS 101B...

Page 2: ...Remote Control Manual PS 81B PS 101B...

Page 3: ...Automatic operation Cooling Heating Fan only operation Drying operation Timer operation Example of timer setting Cautions CONTENTS Model Transmission Distance Lowest Voltage of CPU Emitting Signal Ra...

Page 4: ...6 7 3 8 9 10 11 12 MODE SLEEP LED CLOCK CANCEL TIMER FAN RESET LOCK CLOCK C ON OFF SET TEMP FAN SPEED AUTO F 3 4 SWING Button on some models Push this button the louver will swing up and down automat...

Page 5: ...e time OFF turn off the operation 10 LOCK Button When you press the LOCK button all current settings are locked in and the remote controller does not accept any operation except that of the LOCK Press...

Page 6: ...button Press the ON OFF button again to remove The clock time is indicated only when no AUTO ON OFF timer is set When AUTO TIMER feature is operating it displays the AUTO ON OFF time To check the cur...

Page 7: ...the infrared signal receiver on the indoor unit is used in direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other ele...

Page 8: ...the Clock 5 When the right time is achieved press the CLOCK button or release the or and wait for 5 seconds the clock time stops flashing and the clock starts operating Press the CLOCK button on the r...

Page 9: ...onditioner If the AUTO mode is uncomfortable you can select the desired conditions manually When you select the AUTO mode you do not have to set the fan speed The fan speed will be automatically contr...

Page 10: ...ess to select DRY 2 TEMP TIME button Push the TEMP TIME button to set the desired O o O temperature from 21 C 70 F to 28 C 83 F 3 ON OFF button When the remote controller is off push this button to st...

Page 11: ...1 TIMER button Press the TIMER button the remote displays 0 0 alongside either the TIMER ON or TIMER OFF indicator and will flash 2 TEMP TIME button Press to set the desired time Forward Backward Pres...

Page 12: ...gistered within a 3 second period after pressing the TEMP TIME button so you should continue pressing the button until the desired time is established Otherwise you must repeat the steps again To star...

Page 13: ...F simultaneously etting timers Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the...

Page 14: ...een Remote controller Illustration and USERS MANUAL on function description the description on USERS MANUAL shall prevail This device complies with all national regulations In Canada it complies with...

Page 15: ...Remote Control Manual PS 81B PS 101B 12...

Page 16: ...GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEO...

Reviews: